AD ADIS16203/PCBZ Programmable 360 inclinometer Datasheet

Programmable 360° Inclinometer
ADIS16203
FEATURES
angle data in a convenient format that can be accessed using a
serial peripheral interface (SPI). The SPI interface provides access
to multiple measurements: 360° linear inclination angles, ±180°
linear incline angles, temperature, power supply, and one auxiliary
analog input. Easy access to calibrated digital sensor data provides
developers with a system-ready device, reducing development
time, cost, and program risk.
0° to 360° Inclinometer
±180 output format option
14-bit digital inclination outputs
Linear output, 0.025° resolution
12-bit digital temperature sensor output
Digitally controlled bias calibration
Digitally controlled sample rate
Digitally controlled filtering
Digitally controlled direction/orientation
Dual alarm settings with rate/threshold limits
Auxiliary digital I/O
Digitally activated self-test
Digitally activated low power mode
SPI®-compatible serial interface
Auxiliary 12-bit ADC input and DAC output
Single-supply operation: 3.0 V to 3.6 V
3500 g powered shock survivability
Unique characteristics of the end system are accommodated
easily through several built-in features, such as a single-command
offset calibration, along with convenient sample rate and bandwidth control.
The ADIS16203 offers the following embedded features that
eliminate the need for external circuitry and provide a simplified
system interface:
•
•
•
•
•
APPLICATIONS
Tilt sensing, inclinometers
Platform control, stabilization, and leveling
Motion/position measurement
Monitor/alarm devices (security, medical, safety)
Robotics
Configurable alarm function
Auxiliary 12-bit analog-to-digital converter (ADC)
Auxiliary 12-bit digital-to-analog converter (DAC)
Configurable digital I/O port
Digital self-test function
The ADIS16203 offers two power management features for
managing system-level power dissipation: low power mode
and a configurable shutdown feature.
GENERAL DESCRIPTION
The ADIS16203 is a complete incline-angle measurement system
in a single compact package enabled by the Analog Devices, Inc.,
iSensor™ integration. By enhancing the Analog Devices iMEMS®
sensor technology with an embedded signal processing solution,
the ADIS16203 provides factory-calibrated, sensor-to-digital incline-
The ADIS16203 is available in a 9.2 mm × 9.2 mm × 3.9 mm
laminate-based land grid array (LGA) package with a temperature range of −40°C to +125°C.
FUNCTIONAL BLOCK DIAGRAM
AUX
ADC
AUX
DAC VREF
ADIS16203
TEMPERATURE
SENSOR
INERTIAL
MEMS
SENSOR
SIGNAL
CONDITIONING
AND
CONVERSION
CALIBRATION
AND
DIGITAL
PROCESSING
CS
SPI
PORT
SCLK
DIN
DIGITAL
CONTROL
SELF-TEST
VDD
POWER
MANAGEMENT
ALARMS
DOUT
AUXILIARY
I/O
AUX COM
RST
DIO0 DIO1
06108-001
COM
Figure 1.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2006 Analog Devices, Inc. All rights reserved.
ADIS16203
TABLE OF CONTENTS
Features .............................................................................................. 1
Calibration Register Definition.................................................15
Applications....................................................................................... 1
Alarms ..........................................................................................15
General Description ......................................................................... 1
Sample Period Control ...............................................................18
Functional Block Diagram .............................................................. 1
Filtering Control .........................................................................18
Revision History ............................................................................... 2
Power-Down Control .................................................................19
Specifications..................................................................................... 3
Status Feedback ...........................................................................20
Timing Specifications .................................................................. 5
COMMAND Control.................................................................20
Timing Diagrams.......................................................................... 5
Miscellaneous Control Register ................................................21
Absolute Maximum Ratings............................................................ 6
Peripherals........................................................................................22
ESD Caution.................................................................................. 6
Auxiliary ADC Function ...........................................................22
Pin Configuration and Function Descriptions............................. 7
Auxiliary DAC Function............................................................22
Typical Performace Characteristics................................................ 8
General-Purpose I/O Control ...................................................23
Theory of Operation ...................................................................... 11
Applications .....................................................................................24
Output Response ........................................................................ 11
Hardware Considerations ..........................................................24
Temperature Sensor ................................................................... 11
Grounding and Board Layout Recommendations .................24
Basic Operation............................................................................... 12
Self-Test Tips ...............................................................................24
Serial Peripheral Interface (SPI) ............................................... 12
Band Gap Reference ...................................................................24
Data Output Register Access..................................................... 13
Power-On Reset Operation .......................................................25
Programming and Control............................................................ 14
Second-Level Assembly..............................................................25
Control Register Overview........................................................ 14
Example Pad Layout ...................................................................25
Control Register Access ............................................................. 14
Outline Dimensions........................................................................26
Control Register Details................................................................. 15
Ordering Guide ...........................................................................26
Calibration................................................................................... 15
REVISION HISTORY
8/06—Revision 0: Initial Version
Rev. 0 | Page 2 of 28
ADIS16203
SPECIFICATIONS
TA = −40oC to +125°C, VDD = 3.3 V, tilt = 0°, unless otherwise noted.
Table 1.
Parameter
INCLINOMETER 1
Input Range
Relative Accuracy
Sensitivity
Accuracy Temperature Coefficient
NOISE PERFORMANCE
Output Noise
Noise Density
FREQUENCY RESPONSE
Sensor Bandwidth
Sensor Resonant Frequency
SELF-TEST STATE
Output Change When Active
TEMPERATURE SENSOR
Output at 25°C
Scale Factor
ADC INPUT
Resolution
Integral Nonlinearity
Differential Nonlinearity
Offset Error
Gain Error
Input Range
Input Capacitance
ON-CHIP VOLTAGE REFERENCE
Accuracy
Reference Temperature Coefficient
Output Impedance
DAC OUTPUT
Resolution
Relative Accuracy
Differential Nonlinearity
Offset Error
Gain Error
Output Range
Output Impedance
Output Settling Time
LOGIC INPUTS
Input High Voltage, VINH
Input Low Voltage, VINL
Logic 1 Input Current, IINH
Logic 0 Input Current, IINL
Input Capacitance, CIN
Conditions
Min
Typ
Max
Unit
25°C, maximum filter setting
25°C
360
±0.6
0.025
±0.0167
Degrees
Degrees
Degrees/LSB
Degrees/°C
At 25°C, no averaging
At 25°C, maximum averaging
At 25°C, no averaging
1.0
0.1
0.037
Degrees rms
Degrees rms
Degrees/√Hz
rms
2250
5.5
Hz
kHz
34
Degrees
1278
−2.13
LSB
LSB/°C
12
±2
±1
±4
±2
±40
70
Bits
LSB
LSB
LSB
LSB
V
pF
V
mV
ppm/oC
Ω
12
4
1
±5
±0.5
0 to 2.5
2
10
Bits
LSB
LSB
mV
%
V
Ω
μs
±0.2
−40
10
V
V
μA
μA
pF
At 25°C
0
During acquisition
At 25°C
2.5
20
2.5
−10
+10
5 kΩ/100 pF to GND
For Code 101 to Code 4095
2.0
VIH = VDD
VIL = 0 V
Rev. 0 | Page 3 of 28
0.8
±1
−60
ADIS16203
Parameter
DIGITAL OUTPUTS
Output High Voltage, VOH
Output Low Voltage, VOL
SLEEP TIMER
Timeout Period 2
FLASH MEMORY
Endurance 3
Data Retention 4
CONVERSION RATE
Minimum Conversion Time
Maximum Conversion Time
Maximum Throughput Rate
Minimum Throughput Rate
POWER SUPPLY
Operating Voltage Range VDD
Power Supply Current
Conditions
Min
ISOURCE = 1.6 mA
ISINK = 1.6 mA
2.4
Typ
0.5
Max
Unit
0.4
V
V
128
Seconds
20,000
20
TJ = 85°C
Cycles
Years
244
484
4096
2.066
3.0
Normal mode, SMPL_TIME ≥ 0x08
(fS ≤ 910 Hz) at 25°C
Fast mode, SMPL_TIME ≤ 0x07
(fS ≥ 1024 Hz) at 25°C
Sleep mode at 25°C
Turn-On Time
1
μs
ms
SPS
SPS
3.3
11
3.6
14
V
mA
36
42
mA
500
130
750
μA
ms
This sensor relies on the earth’s gravity to provide accurate incline angle measurements. The axis of rotation must be perpendicular to the earth’s gravity to maintain the
factory-calibrated accuracy of the sensor.
Guaranteed by design.
3
Endurance is qualified as per JEDEC Standard 22 Method A117 and measured at −40°C, +25°C, +85°C, and +125°C.
4
Retention lifetime equivalent at junction temperature (TJ) 55°C as per JEDEC Standard 22 Method A117. Retention lifetime decreases with junction temperature.
2
Rev. 0 | Page 4 of 28
ADIS16203
TIMING SPECIFICATIONS
TA = +25°C, VDD = 3.3 V, tilt = 0°, unless otherwise noted.
Table 2.
Parameter
fSCLK
Description
Fast mode, SMPL_TIME ≤ 0x07 (fS ≥ 1024 Hz)
Normal mode, SMPL_TIME ≥ 0x08 (fS ≤ 910 Hz)
Chip select period, fast mode, SMPL_TIME ≤ 0x07 (fS ≥ 1024 Hz)
Chip select period, normal mode, SMPL_TIME ≥ 0x08 (fS ≤ 910 Hz)
Chip select to clock edge
Data output valid after SCLK falling edge 2
Data input setup time before SCLK rising edge
Data input hold time after SCLK rising edge
Data output fall time
Data output rise time
CS high after SCLK edge 3
tDATARATE
tCS
tDAV
tDSU
tDHD
tDF
tDR
tSFS
Min 1
0.01
0.01
40
100
48.8
Typ
Max
2.5
1.0
Unit
MHz
MHz
μs
μs
ns
ns
ns
ns
ns
ns
ns
100
24.4
48.8
5
5
12.5
12.5
5
1
Guaranteed by design, not production tested.
The MSB presents an exception to this parameter. The MSB clocks out on the falling edge of CS. The rest of the DOUT bits are clocked after the falling edge of SCLK and are
governed by this specification.
3
This parameter may need to be expanded to allow for proper capture of the LSB. After CS goes high, the DOUT line goes into a high impedance state.
2
TIMING DIAGRAMS
tDATARATE
tSTALL
CS
06108-002
SCLK
tSTALL = tDATARATE – 16/fSCLK
Figure 2. SPI Chip Select Timing
CS
tCS
tSFS
1
2
3
4
5
6
15
16
SCLK
tDAV
MSB
DB14
DB13
tDSU
DIN
W/R
DB12
DB11
A4
A3
DB10
DB2
DB1
LSB
tDHD
A5
A2
D2
D1
Figure 3. SPI Timing, Utilizing SPI Settings Typically Identified as Phase = 1, Polarity = 1
Rev. 0 | Page 5 of 28
LSB
06108-003
DOUT
ADIS16203
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
Acceleration (Any Axis, Unpowered)
Acceleration (Any Axis, Powered)
VDD to COM
Digital Input/Output Voltage to COM
Analog Inputs to COM
Operating Temperature Range
Storage Temperature Range
Rating
3500 g
3500 g
−0.3 V to +7.0 V
−0.3 V to +5.5 V
−0.3 V to VDD + 0.3 V
−40°C to +125°C
−65°C to +150°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 4. Package Characteristics
Package Type
16-Lead LGA
θJA
250°C/W
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rev. 0 | Page 6 of 28
θJC
25°C/W
Device Weight
0.6 g
ADIS16203
AUX ADC
VREF
COM
13
14
15
16
AUX DAC 12
ADIS16203
NC 11
BOTTOM
VIEW
(Not to Scale)
AUX COM 10
7
6
5
DIO1
DIO0
NC = NO CONNECT
8
NC
9
AUX COM
RST
1
SCLK
2
DOUT
3
DIN
4
CS
06108-004
VDD
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
Figure 4. Pin Configuration
Table 5. Pin Function Descriptions
Pin No.
1
2
3
4
5, 6
7, 11
8, 10
9
12
13
14
15
16
1
Mnemonic
SCLK
DOUT
DIN
CS
DIO0, DIO1
NC
AUX COM
RST
AUX DAC
VDD
AUX ADC
VREF
COM
Type 1
I
O
I
I
I/O
–
S
I
O
S
I
O
S
Description
SPI Serial Clock.
SPI Data Out.
SPI Data In.
SPI Chip Select, Active Low. This input frames the serial data transfer.
Multifunction Digital I/O Pin.
No Connect.
Auxiliary Grounds. Connect to GND for proper operation.
Reset, Active Low. This input resets the embedded microcontroller to a known state.
Auxiliary DAC Analog Voltage Output.
+3.3 V Power Supply.
Auxiliary ADC Analog Input Voltage.
Precision Reference Output.
Common. Reference point for all circuitry in the ADIS16203.
S = supply, O = output, I = input.
Rev. 0 | Page 7 of 28
ADIS16203
TYPICAL PERFORMACE CHARACTERISTICS
30
90
80
25
INCL_OUT (Degrees)
POPULATION (%)
70
20
15
10
60
50
40
30
20
5
–0.8 –0.6 –0.4 –0.2
0
0.2
0.4
0.6
0.8
1.0
ERROR (Degrees)
0
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.6
3.7
SUPPLY (V)
06108-008
–1.0
06108-032
10
0
Figure 8. Self-Test Shift vs. Supply at 25°C
Figure 5. Inclination Error Distribution at 25°C/3.3 V, Incline = 0°
150
3.5
125
3.0
2.5
QUANTITY
INCL_OUT (Degrees)
100
2.0
1.5
75
1.0
50
0.5
25
0
–0.5
20
40
60
80
100
120
TEMPERATURE (°C)
(µV/LSB)
06108-009
0
06108-006
–20
607.6
607.8
608.0
608.2
608.4
608.6
608.8
609.0
609.2
609.4
609.6
609.8
610.0
610.2
610.4
610.6
610.8
611.0
611.2
611.4
611.6
611.8
612.0
612.2
612.4
0
–1.0
–40
Figure 9. ADC Gain Distribution at 25°C/3.3 V
Figure 6. Inclination Error vs. Temperature
80
0.40
70
0.35
60
QUANTITY
0.25
0.20
50
40
30
0.15
20
0.10
10
0.05
3.1
3.2
3.3
3.4
3.5
SUPPLY VOLTAGE (V)
3.6
3.7
(mV)
Figure 7. Inclination Error vs. Supply
Figure 10. ADC Offset Distribution at 25°C/3.3 V
Rev. 0 | Page 8 of 28
06108-010
3.0
–2.4
–2.1
–1.8
–1.5
–1.2
–0.9
–0.6
–0.3
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
3.3
3.6
3.9
4.2
4.5
4.8
0
0
2.9
06108-033
±ERROR (Degrees)
0.30
ADIS16203
3
45
40
2
1
30
QUANTITY
NONLINEARITY (LSB)
35
0
–1
25
20
15
10
–2
5
8192
12288
16384
ADC CODES
0
(mV)
Figure 14. DAC Offset Distribution at 25°C/3.3 V
Figure 11. Typical ADC Integral Nonlinearity at 25°C/3.3 V
5
3
3.0V/–40°C
3.0V/+25°C
3.0V/+125°C
3.3V /–40°C
3.3V/+25°C
3.3V/+125°C
3.6V/–40°C
3.6V/+25°C
3.6V/+125°C
4
2
3
NONLINEARITY (LSB)
NONLINEARITY (LSB)
06108-014
4096
–2.7
–2.4
–2.1
–1.8
–1.5
–1.2
–0.9
–0.6
–0.3
0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
3.3
3.6
3.9
4.2
4.5
1
06108-011
–3
1
0
–1
2
1
0
–1
–2
–3
–2
4096
8192
12288
16384
ADC CODES
–5
06108-012
1
0
512
1024
1536
2048
2560
3072
3584
4096
DAC CODES
Figure 12. Typical ADC Differential Nonlinearity
06108-015
–4
–3
Figure 15. Typical DAC Integral Nonlinearity
120
250
100
200
QUANTITY
60
150
100
40
50
20
2.4975
2.4977
2.4979
2.4981
2.4983
2.4985
2.4987
2.4989
2.4991
2.4993
2.4995
2.4997
2.4999
2.5001
2.5003
2.5005
2.5007
2.5009
2.5011
2.5013
2.5015
2.5017
2.5019
2.5021
2.5023
06108-013
(µV/LSB)
(V)
Figure 13. DAC Gain Distribution at 25°C/3.3 V
Figure 16. VREF Distribution at 25°C/3.3 V
Rev. 0 | Page 9 of 28
06108-016
0
0
606.6
606.9
607.2
607.5
607.8
608.1
608.4
608.7
609.0
609.3
609.6
609.9
610.2
610.5
610.8
611.1
611.4
611.7
612.0
612.3
612.6
612.9
613.2
613.5
613.8
QUANTITY
80
ADIS16203
60
180
160
50
140
120
QUANTITY
QUANTITY
40
30
20
100
80
60
40
10
20
(µA)
Figure 17. Temperature Distribution at 25°C/3.3 V
06108-020
06108-017
(°C)
370
378
386
394
402
410
418
426
434
442
450
458
466
474
482
490
498
506
514
522
530
538
546
554
562
0
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
25
25
26
26
27
27
0
Figure 20. Sleep Mode Power Supply Current Distribution at 25°C/3.3 V
140
0.0010
SLEEP MODE CURRENT (A)
120
QUANTITY
100
80
60
40
0.0008
0.0006
0.0004
0.0002
20
–30
–10
10
30
50
70
90
110
130
150
TEMPERATURE (°C)
Figure 18. Normal Mode Power Supply Current Distribution at 25°C/3.3 V
06108-021
13.0
(mA)
0
–50
06108-018
12.7
12.4
12.1
11.8
11.5
11.2
10.9
10.6
10.3
10.0
9.7
9.4
0
Figure 21. Sleep Mode Current vs. Temperature at 3.3 V
140
0.0010
SLEEP MODE CURRENT (A)
120
80
60
40
0.0008
0.0006
0.0004
0.0002
20
(mA)
0
2.9
06108-019
29.0
29.6
30.2
30.8
31.4
32.0
32.6
33.2
33.8
34.4
35.0
35.6
36.2
36.8
37.4
38.0
38.6
39.2
39.8
40.4
41.0
41.6
42.2
42.8
43.4
0
3.0
3.1
3.2
3.3
3.4
3.5
3.6
SUPPLY VOLTAGE (V)
Figure 22. Sleep Mode Current vs. Supply Voltage at 25°C
Figure 19. Fast Mode Power Supply Current Distribution at 25°C/3.3 V
Rev. 0 | Page 10 of 28
3.7
06108-022
QUANTITY
100
ADIS16203
THEORY OF OPERATION
The ADIS16203 is a calibrated digital inclinometer that provides a
full 360° of measurement range in any rotational plane that is parallel to
the earth’s gravity. A dual-axis accelerometer provides the base-sensing
function, which resolves the earth’s gravity into two orthogonal vectors,
as displayed in Figure 23. A power-efficient approach to a common
trigonometric identity converts these orthogonal vectors into an inclineangle measurement.
OUTPUT RESPONSE
The incline-angle measurements are linear with respect to
degrees, and the sensor’s orientation produces the output
response displayed in Figure 25. This figure is helpful in
understanding the basic orientation of the inertial sensor
measurement axes.
INCL_OUT = 90°
INCL_180_OUT = 90°
1g
INCL_OUT = 0°
INCL_180_OUT = 0°
1g
a2
a1
0°
BOTTOM
VIEW
(Not to Scale)
06108-036
EARTH’S SURFACE
INCL_OUT = 180°
INCL_180_OUT = 180°
Figure 23. Sensor Measurement Diagram
The digital postprocessing circuit digitizes the sensor outputs
and applies sensitivity/offset calibration coefficients prior to angle
calculations. A factory calibration produces these coefficients using
a full 360° mechanical rotational apparatus. This eliminates the need
for system-level calibration in many cases. In addition to calibrating
the sensor elements, the ADIS16203 corrects for power-supplydependent parameters, providing a more robust calibration.
The accuracy of the incline-angle measurements relies on three
important factors: the absence of external (aside from gravity)
acceleration, managing offset errors introduced during system-level
configuration, and maintaining a proper axis of rotation (rotation
plane parallel with earth’s gravity). All of these factors can influence
the acceleration measurements and introduce error. The ADIS16203
provides a simple method for calibrating configuration errors by
providing the INCL_NULL register function. See the Calibration
section for more details. In addition, a 10° tilt plane error can
introduce as much as ±1° of error in the incline-angle outputs.
INCL_OUT = 270°
INCL_180_OUT = –90°
06108-023
EARTH’S SURFACE
Figure 25. Output Response vs. Orientation
TEMPERATURE SENSOR
An internal temperature sensor monitors the accelerometer’s
junction temperature. The TEMP_OUT data register provides
a digital representation of this measurement. This sensor provides
a convenient temperature measurement for system-level characterization and calibration feedback.
SYSTEM-LEVEL ORIENTATION OFFSET
TILT PLANE ERROR
PCB
ATTACHMENT
OFFSET
EARTH’S SURFACE
06108-038
IDEAL = 90°
Figure 24. ADIS16203 System-Level Orientation
Rev. 0 | Page 11 of 28
ADIS16203
BASIC OPERATION
SCLK have no impact on operation. A complete data frame contains
16 clock cycles. Because the SPI port operates in full duplex mode,
it supports simultaneous, 16-bit receive (DIN) and transmit (DOUT)
functions during the same data frame.
The ADIS16203 is designed for simple integration into industrial
system designs, requiring only a 3.3 V power supply and a 4-wire,
industry standard SPI. The SPI port facilitates all data transfers
with the ADIS16203’s registers. Each ADIS16203 function (output
data and programming control) has its own register that contains
two bytes of data, and each byte of data has its own unique bit
map. These two bytes are referred to as upper and lower bytes,
and each has its own 6-bit address.
Figure 26 displays a typical data frame for writing a command to a
control register. In this case, the first bit of the DIN sequence is a
1, followed by a 0, then the 6-bit address and 8-bit data command.
Because each write command covers a single byte of data, two data
frames are required when writing the entire 16-bit space of a register.
SERIAL PERIPHERAL INTERFACE (SPI)
The ADIS16203’s SPI port provides a common interface that is
supported by a wide variety of digital platforms, including MCUs,
DSPs, and FPGAs. Even when a dedicated port is not available, the
SPI can be implemented using manual bit manipulation, which is
more commonly known as bit banging. The purpose of this section is
to provide a basic description of SPI operation in the ADIS16203.
Please refer to Table 2, Figure 2, and Figure 3 for detailed timing
and operation of this port.
Reading the contents of a register requires a modification to the
sequence in Figure 26. In this case, the first two bits in the DIN
sequence are 0, followed by the address of the register. Each register
has two addresses, but either one can be used to access its entire
16 bits of data. The final eight bits of the DIN sequence are irrelevant
and can be counted as don’t cares during a read command. Then,
during the next data frame, the DOUT sequence will contain the
register’s 16-bit data, as shown in Figure 27. Even though a single
read command requires two separate data frames, the full duplex
mode minimizes this overhead, requiring only one extra data frame
when continuously sampling.
The ADIS16203’s SPI port includes four signals: chip select
(CS), serial clock (SCLK), data input (DIN), and data output
(DOUT). The CS line enables the ADIS16203’s SPI port and, in
effect, frames each SPI event. When this signal is high, the DOUT
lines are in a high impedance state and the signals on DIN and
DATA FRAME
CS
SCLK
W/R
A5
A4
A3
A2
A1
REGISTER ADDRESS
WRITE = 1
READ = 0
A0
DC7
DC6
DC5 DC4
DC3
DC2
DC1
DATA FOR WRITE COMMANDS
DON’T CARE FOR READ COMMANDS
DC0
06108-037
DIN
Figure 26. DIN Bit Sequence
CS
DATA FRAME
DATA FRAME
SCLK
W/R BIT
DOUT
ADDRESS
DON’T CARE
NEXT COMMAND
ZERO
BASED ON PREVIOUS COMMAND
16-BIT REGISTER CONTENTS
Figure 27. SPI Sequence for Read Commands
Rev. 0 | Page 12 of 28
06108-024
DIN
ADIS16203
DATA OUTPUT REGISTER ACCESS
The MSB holds the new data (ND) indicator. When the output
registers are updated with new data, the ND bit goes to a 1 state.
After the output data is read, it returns to a 0 state. The EA bit is
used to indicate an alarm condition, which could result from a
number of conditions, such as a power supply that is out of the
specified operating range. See the Alarms section for more details.
The ADIS16203 provides access to two calibrated incline-angle
measurements (+360° and ±180° output formats), power supply
measurements, temperature measurements, and an auxiliary
12-bit ADC channel. This output data is continuously updating
internally, regardless of user read rates. The follow bit map describes
the structure of all output data registers in the ADIS16203.
MSB
The output data is either 12 or 14 bits in length. For all of the 12-bit
output data, the D13 and D12 bits are assigned don’t care status.
LSB
ND
EA
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
The output data register map is located in Table 6 and provides all
of the necessary details for accessing each register’s data. Table 7
displays the output coding for the ±180° output data register,
INCL_180_OUT, and Figure 28 displays a timing diagram
example for reading this register.
Table 6. Data Output Register Information
Name
SUPPLY_OUT
AUX_ADC
TEMP_OUT
INCL_OUT
INCL_180_OUT
Function
Power supply data
Auxiliary analog input data
Sensor temperature data
Inclination data
±180° inclination data
Resolution
(Bits)
12
12
12
14
14
Address
0x03, 0x02
0x09, 0x08
0x0B, 0x0A
0x0D, 0x0C
0x0F, 0x0E
Data
Format
Binary
Binary
Binary
Binary
Twos complement
Scale Factor
(per LSB)
1.22 mV
0.61 mV
−0.47°C
0.025°
0.025°
Table 7. Output Coding Example, INCL_180_OUT 1, 2
Acceleration Level
+170.10°
+93.05°
+0.625°
0.00°
−0.625
−93.05°
−170.10°
2
Hex Output
0x1A94
0x0E8A
0x0019
0x0000
0x3FE7
0x3176
0x256C
Decimal
+6804
+3722
+25
0
−25
−3722
−6804
Two MSBs have been masked off and are not considered in the coding.
Nominal sensitivity (0.025°/LSB) and zero offset null performance are assumed.
CS
SCLK
DIN
W/R BIT = 0
ADDRESS = 001111
W/R BIT = 0
ADDRESS = 001111 OR 0x0F
DOUT
DATA = 1000111010001010
NEW DATA, NO ALARM, INCL_180_OUT = +93.05°
Figure 28. SPI Sequence Reading INCL_OUT When Incline Angle = 93.05°
Rev. 0 | Page 13 of 28
06108-025
1
Binary Output
01 1010 1001 0100
00 1110 1000 1010
00 0000 0001 1001
00 0000 0000 0000
11 1111 1110 0111
11 0001 0111 0110
11 1100 0001 1000
ADIS16203
PROGRAMMING AND CONTROL
CONTROL REGISTER OVERVIEW
CONTROL REGISTER ACCESS
The ADIS16203 offers many programmable features that are
controlled by writing commands to the appropriate control registers
using the SPI. For added system flexibility and programmability,
the following sections describe these controls and specify each
register’s configuration. A list of features that are available for
configuration in this register space follows:
Table 8 displays the control register map for the ADIS16203,
including address, volatile status, basic function, and accessibility
(read/write). The following sections contain detailed descriptions
and configurations for each of these registers.
•
Calibration: Automatic offset null, manual offset adjustment,
factory reset
•
Rotational direction: clockwise or counter-clockwise
•
Sample rate adjustment
•
Filter response optimization
•
Alarm settings: threshold or rate of change, and comparison
with filtered or unfiltered data
•
I/O configuration: data ready, etc.
•
Power management: sleep mode, normal and high
performance modes
•
Auxiliary DAC level setting
•
Status checks: verify power supply, SPI communication,
package orientation
•
Flash™ updates to store configuration
The ADIS16203 is a Flash-based device with the nonvolatile
functional registers implemented as Flash registers. Take into
account the endurance limitation of 20,000 writes when considering the system-level integration of these devices. The nonvolatile
column in Table 8 indicates the registers that are recovered on powerup. The user must use a manual Flash update command (using the
command register) to store the nonvolatile data registers once they
are configured properly. When performing a manual Flash update
command, the user needs to ensure that the power supply remains
within limits for a minimum of 50 ms after the start of the update.
This ensures a successful write of the nonvolatile data.
Table 8. Control Register Mapping
Register Name
Type
Nonvolatile
INCL_NULL
ALM_MAG1
ALM_MAG2
ALM_SMPL1
ALM_SMPL2
ALM_CTRL
R/W
R/W
R/W
R/W
R/W
R/W
X
X
X
X
X
X
AUX_DAC
GPIO_CTRL
MSC_CTRL
SMPL_TIME
AVG_CNT
SLP_CNT
STATUS
COMMAND
R/W
R/W
R/W
R/W
R/W
R/W
R
W
X
X
X
Address
0x00 to 0x01
0x18
0x20
0x22
0x24
0x26
0x28
0x2A to 0x2F
0x30
0x32
0x34
0x36
0x38
0x3A
0x3C
0x3E
Bytes
2
2
2
2
2
2
2
6
2
2
2
2
2
2
2
2
Function
Reserved
Incline null calibration
Alarm 1 amplitude threshold
Alarm 2 amplitude threshold
Alarm 1 sample period
Alarm 2 sample period
Alarm source control register
Reserved
Auxiliary DAC data
Auxiliary digital I/O control register
Miscellaneous control register
ADC sample period control
Defines number of samples used by moving average filter
Counter used to determine length of power-down mode
System status register
System command register
Rev. 0 | Page 14 of 28
ADIS16203
CONTROL REGISTER DETAILS
All ADIS16203 control registers are organized into 2-byte segments,
and both upper (Bit 8 to Bit 15) and lower (Bit 0 to Bit 7) bytes have
unique addresses and can be accessed individually.
MSB
LSB
1
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
This section provides a description of each register, including its
purpose, relevant scaling information, bit maps, addresses, and
default values.
CALIBRATION
Scale1
0.025°
Default
0x0000
Format
Binary
Access
R/W
Scale is the weight of each LSB.
The INCL_NULL register is the user controlled register for
calibrating system-level inclination offset errors. The maximum
calibration range is +0° to +359.975° or 0 to +14,399 decimal
codes. The contents of this register are nonvolatile.
Table 10. INCL_NULL Bit Designations
In addition to the factory calibration, the ADIS16203 provides
two user calibration options. Both options utilize the INCL_NULL
control register, which provides an add function to the two inclineangle output registers: INCL_OUT and INCL_180_OUT. Because
the default contents of INCL_NULL are 0, adding it to these two
outputs has no effect on the output data.
The first calibration option is an automatic null function. This function
measures the contents of INCL_OUT and then writes the inverse of
this value into the INCL_NULL control register. The accuracy of this
calibration is dependent on the stability of the INCL_OUT measurement; therefore, maximizing the filtering will minimize the errors
associated with noise. Table 9 displays a sequence that executes the
automatic null.
Table 9. Automatic Null Sequence
Wait for 512 samples
Write 0x01 to Address 0x3E
INCL_NULL Register Definition
Address
0x19, 0x18
D15
Step
Write 0x08 to Address 0x38
CALIBRATION REGISTER DEFINITION
Description
Sets averaging count to 256
using the AVG_CNT register
Waits for the lowest noise data
Executes the global autonull
function using the COMMAND
register
Restore previous average count
Increasing the sample rate using the SMPL_TIME control register
will minimize the waiting time if this parameter is critical.
The second option for system-level calibration is manual adjustment.
The INCL_NULL control register can be updated using write commands. Refer to its definition in the INCL_NULL Register Definition
section for details.
The factory calibration can be restored by writing 0x02 to Register
Address 0x3E. This restores INCL_NULL to 0.
Bit
15:14
13:0
Description
Not necessary, force to 0
Data bits
ALARMS
The ADIS16203 contains two independent alarm functions that
are referred to as Alarm 1 and Alarm 2. The Alarm 1 function is
managed by the ALM_MAG1 and ALM_SMPL1 control registers.
The Alarm 2 function is managed by the ALM_MAG2 and
ALM_SMPL2 control registers. Both the Alarm 1 and Alarm 2
functions share the ALM_CTRL register. For simplicity, this
section refers to the Alarm 1 functionality only.
The 16-bit ALM_CTRL register serves several roles in controlling
the Alarm 1 function. First, it is used to enable the overall Alarm 1
function and to select the output data variable that is to be
monitored for the alarm condition. Second, it is used to select
whether the Alarm 1 function is based upon a predefined threshold
(THR) level or a predefined rate-of-change (ROC) slope. Third,
the ALM_CTRL register can be used in setting up one of the
two general-purpose input/output lines (GPIOs) to serve as a
hardware output that indicates when an alarm condition has
occurred. Enabling the I/O alarm function as well as setting its
polarity and controlling its operation are accomplished using
this register. Fourth, this register provides the controls for
setting the comparison data as filtered or unfiltered.
Note that when enabled, the hardware output indicator serves
both the Alarm 1 and Alarm 2 functions and cannot be used to
differentiate between one alarm condition and the other. It is
simply used to indicate that an alarm is active and that the user
should poll the device via the SPI to determine the source of the
alarm condition (see the STATUS Register Definition section).
Because the ALM_CTRL, MSC_CTRL, and GPIO_CTRL
control registers can influence the same GPIO pins, a priority
level has been established to avoid conflicting assignments of
the two GPIO pins. This priority level is defined as MSC_CTRL,
which has precedence over ALM_CTRL, which has precedence
over GPIO_CTRL.
Rev. 0 | Page 15 of 28
ADIS16203
The ALM_MAG1 control register used in controlling the Alarm 1
function has two roles. The first role is to store the value with which
the output data variable is compared against to discern if an alarm
condition exists. The second role is to identify whether the alarm
should be active for excursions above or below the alarm limit. If 1 is
written to Bit 15 of the ALM_MAG1 control register, the alarm is
active for excursions extending above a given limit. If 0 is written to
Bit 15, the alarm is active for excursions dropping below the given
limit. The comparison value contained within the ALM_MAG1
control register is located within the lower 14 bits.
Bits 4 and 5 in the ALM_CTRL register establishes whether
ALM_MAG1 and ALM_MAG2 are compared with filtered or
unfiltered data.
The monitored output register establishes the format of the
14-bit data space in the ALM_MAG1 and ALM_MAG2 registers. For
example, setting the alarm to monitor INCL_OUT sets the data
format to a 14-bit, twos complement number, which carries a bit
weight of 0.025°.
The ALM_MAG1 register contains the threshold level for
Alarm 1. The contents of this register are nonvolatile.
ALM_MAG1 Register Definition
Address
0x21, 0x20
1
2
The versatility built into the alarm function allows the user to adapt
to several applications. For example, in the case of monitoring twos
complement variables, Bit 15 within the ALM_MAG1 control register
can allow for the detection of negative excursions below a fixed level.
In addition, the Alarm 1 and Alarm 2 functions can be set to monitor
the same variable that allows the user to discern if an output variable
remains within a predefined window.
Another potential ROC application is to monitor slowly changing
outputs in the inclination level. With the addition of the alarm hardware functionality, the ADIS16203 can be left to run independently
of the main processor and interrupt the system only when an alarm
condition occurs. Conversely, the alarm condition can be monitored
through the routine polling of any one of the seven data output registers.
Format2
N/A
Access
R/W
Default is valid only until the first register write cycle.
Format is established by source of monitored data
Table 11. ALM_MAG1 Bit Designations
Bit
15
Use caution when monitoring the temperature output register for the
alarm conditions. Here, the negative temperature scale factor results
in the greater than and less than selections requiring reverse logic.
Setting Bit 11 in the ALM_CTRL register establishes the mode of
operation: threshold or rate of change (ROC). When the ROC
function is enabled, the comparison of the output data variable is
against the ALM_MAG1 level averaged over the number of samples
as identified in the ALM_SMPL1 control register. This acts to create
a comparison of (Δ units/Δ time) or the derivative of the output data
variable against a predefined slope.
Default1
0x0000
14
13:0
Description
Greater than Active Alarm Bit.
1: Alarm is active for an output greater than
ALM_MAG1 register setting.
0: Alarm is active for an output less than
ALM_MAG1 register setting.
Not used.
Data Bits. This number can be either twos complement
or straight binary. The format is set by the value being
monitored by this function.
ALM_SMPL1 Register Definition
Address
0x25, 0x24
1
Default1
0x0000
Format
Binary
Access
R/W
Default is valid only until the first register write cycle.
The ALM_SMPL1 register contains the sample period information
for Alarm 1, when it is set for ROC alarm monitoring. The ROC
alarm function averages the change in the output variable over the
specified number of samples and compares this change directly
to the values specified in the ALM_MAG1 register. The contents
of this register are nonvolatile.
Table 12. ALM_SMPL1 Bit Designations
Bit
15:8
7:0
Rev. 0 | Page 16 of 28
Description
Not used
Data bits
ADIS16203
Table 15. ALM_CTRL Bit Designations
ALM_MAG2 Register Definition
Address
0x23, 0x22
1
2
1
Default
0x0000
2
Format
N/A
Bit
15
Access
R/W
Default is valid only until the first register write cycle.
Format is established by source of monitored data.
14:12
000
001
010
011
100
101
110
111
The ALM_MAG2 register contains the threshold level for Alarm 2.
The contents of this register are nonvolatile.
Table 13. ALM_MAG2 Bit Designations
Bit
15
14
13:0
Description
Greater than Active Alarm Bit.
1: Alarm is active for an output greater than
ALM_MAG2 register setting.
0: Alarm is active for an output less than
ALM_MAG2 register setting.
Not used.
Data Bits. This number can be either twos complement
or straight binary. The format is set by the value being
monitored by this function.
11
10:8
000
001
010
011
100
101
110
111
ALM_SMPL2 Register Definition
Address
0x27, 0x26
1
Default1
0x0000
Format
Binary
Access
R/W
Default is valid only until the first register write cycle.
The ALM_SMPL2 register contains the sample period information
for Alarm 2, when it is set for ROC alarm monitoring. The ROC
alarm function averages the change in the output variable over the
specified number of samples and compares this change directly to
the values specified in the ALM_MAG2 register. The contents of this
register are nonvolatile.
7:6
5
4
3
2
Table 14. ALM_SMPL2 Bit Designations
Bit
15:8
7:0
Description
Not used
Data bits
1
ALM_CTRL Register Definition
Address
0x29, 0x28
1
Default1
0x0000
Format
N/A
Value
Access
R/W
0
Default is valid only until the first register write cycle.
The ALM_CTRL register contains the alarm control variables.
Rev. 0 | Page 17 of 28
Description
Rate of Change (ROC) Enable for Alarm 2
1: ROC is active
0: ROC is inactive
Alarm 2 Source Selection
Alarm disable
Alarm source: power supply output
Not used
Not used
Alarm source: auxiliary ADC output
Alarm source: temperature sensor output
Alarm source: INCL_OUT output
Alarm source: INCL_180_OUT output
Rate of Change (ROC) Enable for Alarm 1
1: ROC is active
0: ROC is inactive
Alarm 1 Source Selection
Alarm disable
Alarm source: power supply output
Not used
Not used
Alarm source: auxiliary ADC output
Alarm source: temperature sensor output
Alarm source: INCL_OUT output
Alarm source: INCL_180_OUT output
Not used
ADF2—Alarm Data Filter
1: Use filtered data for comparison
0: Use instantaneous data for comparison
ADF1—Alarm Data Filter
1: Use filtered data for comparison
0: Use instantaneous data for comparison
Not used
Alarm Output Enable
1: Alarm output enabled
0: Alarm output disabled
Alarm Output Polarity
1: Active high
0: Active low
Alarm Output Line Select
1: DIO1
0: DIO0
ADIS16203
Table 16. SMPL_TIME Bit Descriptions
SAMPLE PERIOD CONTROL
The output data variables within the ADIS16203 are sampled and
updated at a rate based upon the SMPL_TIME control register. The
sample period can be precisely controlled over more than a threedecade range using a time base with two settings and a 7-bit binary
count. The use of a time base that varies with a ratio of 1:31 allows
for a more optimum resolution in the sample period than a straight
binary counter. This is reflected in Figure 29, where the frequency is
presented on a logarithmic scale.
Bit
15:8
7
6:0
Note that the sample period given is defined as the cumulative time
required to sample, process, and update all data output variables. The
data output variables are sampled as a group and in unison with one
another. Whatever update rate is selected for one signal, all output
data variables are updated at the same rate whether they are monitored
via the SPI or not.
For a sample period setting of less than 1098.9 μs (SMPL_TIME ≤
0x07), the overall power dissipation in the part rises by approximately 300%.
256
SMPL_TIME VALUE
192
128
FILTERING CONTROL
The ADIS16203 uses two types of filters for the output data. The
INCL_OUT and INCL_180_OUT data outputs use a Bartlett
Window function, and the SUPPLY_OUT, AUX_ADC, and
TEMP_OUT data outputs use a standard moving-averaging
filter. The number of taps set by the AVG_CNT control register
establishes the frequency response. The number of taps can be
derived from the contents of AVG_CNT using the following
equation:
N = 2 AVG _ CNT
64
1
10
100
1k
10k
FREQUENCY (Hz)
06108-026
The following equations characterize the expected behavior of
each filtering approach. Figure 30 and Figure 31 shows the
frequency responses of each filter approach.
0
Averaging:
Figure 29. SMPL_TIME Values vs. Sample Frequency
HA( f ) =
SMPL_TIME Register Definition
Address
0x37, 0x36
1
Description
Not used.
ADC Time Base Control. The MSB and TMBS set the
time base of the acquisition system to 122.1 μs when
SR7 = 0 vs. 3.784 ms when SR7 = 1.
ADC Sample Period Count. The lower seven bits, SP6
to SP0, represent a binary count that results in the
combined sample period of the ADC when added to
one and then multiplied by the time base. (The
combined sample period is the period required to
sample and update all seven data outputs.) The
minimum setting for the lower seven bits, SP6 to SP0,
is 0x01. The overall acquisition time can be varied
from 244.2 μs to 15.51 ms in 122.1 μs increments for
TMBS = 0 and from 7.57 ms to 481 ms in 3.784 ms
increments for TMBS = 1. This equates to the sample
rate varying from 4096 SPS to 64.5 SPS for TMBS = 0
and from 132 SPS to 2.08 SPS for TMBS = 1.
Default1
0x0008
Format
N/A
Access
R/W
Bartlett Window:
H B ( f ) = H A2 ( f )
Default is valid only until the first register write cycle.
The data within this register is nonvolatile, allowing for data
recovery upon reset.
sin(π × N × f × t s )
N × sin(π × f × t s )
The primary difference in the frequency responses offered by
each approach lies in their side lobes, which are 13 dB better in
the Bartlett Windowing approach. The Bartlett Window filtering
has two times the latency of the moving average filter.
Rev. 0 | Page 18 of 28
ADIS16203
20
POWER-DOWN CONTROL
CORE SENSOR
RESPONSE
AVG_CNT = 1
N=2
The ADIS16203 has the ability to power down for user-defined
amounts of time, using the SLP_CNT control register. The
amount of time specified by the SLP_CNT control register is
equal to the binary count of the 8-bit control word multiplied
by 0.5 sec. Therefore, the 255 codes cover an overall shutdown
period of 127.5 seconds. The SLP_CNT register is volatile and is
set to 0 upon both power-up and subsequent wake-ups from the
power-down period. By setting the SLP_CNT control register to
a nonzero state, the ADIS16203 automatically powers down
once the next sample period is completed and the data output
registers are updated.
ATTENUATION (dB)
0
AVG_CNT = 4
N = 16
–20
AVG_CNT = 8
N = 256
–60
10
1
100
1000
10000
FREQUENCY (Hz)
06108-034
–40
Once the ADIS16203 is placed into power-down mode, it can
only return to normal operation by timing out, by a reset command
(using the RST hardware control line), or by cycling the power
applied to the part. Once awake, the data output registers can be
scanned to determine what the state of the output registers were
prior to powering down. Once the data is recovered, the device
can be powered down again by simply writing a nonzero value
to the SLP_CNT control register and starting the process over.
Figure 30. INCL_OUT, INCL_180_OUT Filter Response
20
AVG_CNT = 1
N=2
ATTENUATION (dB)
0
AVG_CNT = 4
N = 16
–20
AVG_CNT = 8
N = 256
–60
10
1
100
1000
10000
FREQUENCY (Hz)
06108-035
–40
Figure 31. SUPPLY_OUT, AUX_ADC, and TEMP_OUT Filter Response,
fS = 4096 SPS
AVG_CNT Register Definition
Address
0x39, 0x38
1
Default1
0x0007
Format
Binary
Access
R/W
SLP_CNT Register Definition
Address
0x3B, 0x3A
Default is valid only until the first register write cycle.
The AVG_CNT register contains information that represents the
number of averages to be applied to the output data. The number of
averages can be calculated by powers of 2. The number of averages
can be set to 1, 2, 4, 8, 16, 32, 64, 128, or 256.
Table 17. AVG_CNT Bit Description
Bit
15:4
3:0
Description
Not used
Data bits (maximum = 1000, or a decimal value of 8)
Once the power-down time is complete, the recovery time for
the ADIS16203 is approximately 2 ms. This recovery time is
implemented within the device to allow for recovery of the
ADC prior to performing the next data conversion. Note that
the ND data bit within the data output control registers is cleared
when the ADIS16203 is powered down. Likewise, the new data
hardware I/O line is placed into an inactive state prior to being
powered down. The DAC is placed into a power-down mode as
well, resulting in the DAC output dropping to 0 V during the
power-down period. All control register settings are retained
while powered down with the exception of the SLP_CNT
control register.
1
Default1
0x0000
Format
Binary
Default is valid only until the first register write cycle.
Table 18. SLP_CNT Bit Descriptions
Bit
15:8
7:0
Rev. 0 | Page 19 of 28
Description
Not used
Data bits
Access
R/W
ADIS16203
STATUS FEEDBACK
COMMAND CONTROL
The status control register within the ADIS16203 is utilized in determining the present state of the device. The ability to monitor the device
becomes necessary when and if the ADIS16203 has registered an alarm
and/or error condition as indicated by the alarm enable (Bit 14) within
the output data registers.
The COMMAND control register is utilized in sending global
commands to the ADIS16203 device. Any one of the global
commands can be implemented by simply writing 1 to its
corresponding bit location. The command control register has
write-only capability and is volatile. Table 20 describes each of
these global commands.
STATUS Register Definition
Address
0x3D, 0x3C
1
Default1
0x0000
Format
N/A
COMMAND Register Definition
Access
Read only
Address
0x3F, 0x3E
Default is valid only until the first register write cycle.
1
The STATUS control register contains the alarm/error flags that
indicate abnormal operating conditions. See Table 19 for each bit’s
definition. Bit 0 and Bit 1 will automatically clear when the power
supply is in the specified range of operation. Setting Bit 4 in the
COMMAND register clears all flags. The flags are set on a continuing
basis as long as the error or alarm conditions persist.
Table 19. STATUS Bit Descriptions
Bit
15:10
9
8
7
6
5
3
2
1
0
Description
Not used
Alarm 2 Status
1: Active
0: Normal mode
Alarm 1 status
1: Active
0: Normal mode
Not used
Invalid Orientation
1: Invalid orientation
0: Normal mode
Self Test Fail
1: Self-test failure
0: Self-test pass
SPI Communications Failure
1: Error condition
0: Normal mode
Control Register Update Failed
1: Error condition
0: Normal mode.
Power Supply Above 3.625 V
1: Error condition
0: Normal mode
Power Supply Below 2.975 V
1: Error condition
0: Normal mode
Default1
0x0000
Format
N/A
Access
Write only
Default is valid only until the first register write cycle.
Table 20. COMMAND Bit Descriptions
Bit
15:8
7
6:5
4
3
2
1
0
Rev. 0 | Page 20 of 28
Description
Not used.
Software Reset Command.
Not used.
Clear Status Register, once per activation
Manual Flash Update Command. This command is
utilized in updating all of the nonvolatile registers to
Flash. Once the command is initiated, the supply
voltage, VDD, must remain within specified limits for
50 ms to ensure proper update of the nonvolatile
registers to Flash.
Auxiliary DAC Latch Command. This command acts to
latch the AUX_DAC control register data into the
auxiliary DAC upon receipt of the command. This allows
for sequential loading of the upper and lower AUX_DAC
data bytes via the SPI without having the auxiliary DAC
transition into unwanted, intermediate states based
upon the individual AUX_DAC data bytes. Once the two
bytes of AUX_DAC are loaded, the DAC latch command
is initiated to move the data into the auxiliary DAC itself.
Factory Reset Command. This command allows the user
to reset the INCL_NULL register to its nominal setting
(0x0000) upon receipt of the command. Data within the
moving average filters is reset. As the manual Flash
command (COMMAND register, Bit 3), this command
stores all of the nonvolatile registers to Flash. Once the
command is initiated, the supply voltage, VDD, must
remain within specified limits for 50 ms to ensure
proper update of the nonvolatile registers to Flash.
Null Command. This command loads the inclination
offset register with a value that zeros out the inclination
and outputs. Useful as a single command to simultaneously zero the inclination outputs. As the manual
Flash command (COMMAND register, Bit 3), this command
stores all of the nonvolatile registers to Flash. Once the
command is initiated, the supply voltage, VDD, must
remain within specified limits for 50 ms to ensure
proper update of the nonvolatile registers to Flash.
ADIS16203
MSC_CTRL Register Definition
MISCELLANEOUS CONTROL REGISTER
The MSC_CTRL control register governs the operation of several
miscellaneous features: using the general purpose I/O for data-ready
(DR) hardware I/O function, reversing the polarity of rotation
(clockwise vs. counter clockwise), and self-test. The control bits for
each of these functions are described in Table 21.
The operation of the data-ready hardware I/O function is very similar to
the alarm hardware I/O function (controlled through the ALM_CTRL
control register). In this case, the MSC_CTRL register can be used in
setting up one of the GPIO pins to serve as the hardware output pin
that indicates when the sampling, conversion, and processing of the
data output variables have been completed. This register provides
the ability to enable the data-ready hardware function and establish
its polarity.
The data-ready hardware I/O pin is reset automatically to an inactive
state part way through the next conversion cycle, resulting in a pulse
train with a duty cycle varying from ~15% to 35%, depending upon
the sample period setting. Upon completion of the next data processing
cycle, the data ready hardware I/O line is set to 1.
Address
0x35, 0x34
1
Default1
0x0000
Format
N/A
Access
R/W
Default is valid only until the first register write cycle.
The 16-bit miscellaneous control register is used in the controlling
of the self-test and data-ready hardware functions. This includes
turning on and off the self-test function, as well as configuring
the data-ready function. For the data-ready function, the written
values are nonvolatile, allowing for data recovery upon reset.
The self-test data is volatile and is set to 0s upon reset. This
register has read/write capability.
Table 21. MSC_CTRL Bit Descriptions
Bit
15:11
10
The MSC_CTRL, ALM_CTRL, and GPIO_CTRL control registers
can influence the same GPIO pins. A priority level has been established
to avoid conflicting assignments of the two GPIO pins. This priority
level is defined as MSC_CTRL and has precedence over ALM_CTRL,
which has precedence over GPIO_CTRL.
9
The self-test operation exercises the base accelerometer’s mechanical
structure and establishes a mechanical diagnostic test. The self-test
offers the ability to have the ADIS16203 run an internal diagnostic
test, which returns a pass/fail condition (see the STATUS register
definition of Bit 5 in Table 19). This feature also provides the ability
to observe the incline angle outputs during the self-test function,
which is nominally 37°, regardless of the incline angle of the device.
Note that a self-test changes the contents of SMPL_TIME to improve
the speed of this test. Upon completion, the ADIS16203 restores the
original contents to SMPL_TIME.
7:3
2
8
1
0
Rev. 0 | Page 21 of 28
Description
Not used
No Self-Test on Power-Up
1: No self-test on power-up or reset
0: Self-test on power-up enabled (typically requires
approximately 13 ms in high performance mode and
approximately 35 ms in low power mode with every
power-up or reset)
Reverse Rotation
1: Reverses rotation of both inclination outputs
0: Normal operation
Self-Test Enable
1: ST enabled (continuous self-test)
0: ST disabled
Not used
Data-Ready Enable
1: DR enabled
0: DR disabled
Data-Ready Polarity
1: Active high
0: Active low
Data-Ready Line Select
1: DIO1
0: DIO0
ADIS16203
PERIPHERALS
AUXILIARY ADC FUNCTION
AUXILIARY DAC FUNCTION
The auxiliary ADC function integrates a standard 12-bit ADC
into the ADIS16203 to digitize other system-level analog signals.
The output of the ADC can be monitored through the AUX_ADC
control register, as defined in Table 6. The ADC consists of a 12-bit
successive approximation converter. The output data is presented in
straight binary format with the full-scale range extending from 0 V
to VREF. A high precision, low drift, factory-calibrated 2.5 V reference
is also provided.
The auxiliary DAC function integrates a standard 12-bit DAC
into the ADIS16203. The DAC output is buffered and fed off-chip
to allow for the control of miscellaneous system-level functions.
Data downloads through the writing of two adjacent data bytes
as defined in its register definition. To prevent the DAC from
transitioning through inadvertent states during data downloads,
a single command is used to simultaneously latch both data bytes
into the DAC after they have been written into the AUX_DAC
control register. This command is implemented by writing 1 to
Bit 2 of the command control register and, once received, results in
the DAC output transitioning to the desired state.
Figure 32 shows the equivalent circuit of the analog input structure
of the ADC. The input capacitor, C1, is typically 4 pF and can be
attributed to parasitic package capacitance. The two diodes provide
ESD protection for the analog input. Care must be taken to ensure
that the analog input signals never exceed the supply rails by more
than 300 mV. This would cause these diodes to become forward-biased
and to start conducting. These diodes can handle 10 mA without
causing irreversible damage to the part. The resistor is a lumped
component that represents the on resistance of the switches. The
value of this resistance is typically 100 Ω. Capacitor C2 represents
the ADC sampling capacitor and is typically 16 pF.
VDD
C1
D
R1 C2
AUX_DAC Register Definition
06108-028
D
The DAC output provides an output range of 0 V to 2.5 V. The
DAC output buffer features a true rail-to-rail output stage. This
means that, unloaded, the output is capable of reaching within
5 mV of ground. Moreover, the DAC’s linearity performance
(when driving a 5 kΩ resistive load to ground) is good through
the full transfer function, except for Code 0 to Code 100. Linearity
degradation near ground is caused by saturation of the output
amplifier. As the output is forced to sink more current, the nonlinear region at the bottom of the transfer function becomes
larger. Larger current demands can significantly limit output
voltage swing.
Address
0x31, 0x30
Figure 32. Equivalent Analog Input Circuit
Conversion Phase: Switch Open
Track Phase: Switch Closed
1
For ac applications, removing high frequency components from the
analog input signal is recommended through the use of an RC lowpass filter on the relevant analog input pins.
In applications where harmonic distortion and signal-to-noise ratio
are critical, the analog input should be driven from a low impedance
source. Large source impedances significantly affect the ac performance
of the ADC. This can necessitate the use of an input buffer amplifier.
When no input amplifier is used to drive the analog input, the source
impedance should be limited to values less than 1 kΩ. The maximum
source impedance depends on the amount of total harmonic distortion
(THD) that can be tolerated.
Default1
0x0000
Format
Binary
Access
R/W
Default is valid only until the first register write cycle.
The AUX_DAC register controls the DAC function of the
ADIS16203. The data bits provide a 12-bit binary format number,
with 0 representing 0 V and 0x0FFFh representing 2.5 V. The
data within this register is volatile and is set to 0s upon reset.
This register has read/write capability.
Table 22. AUX_DAC Bit Descriptions
Bit
15:12
11:0
Rev. 0 | Page 22 of 28
Description
Not used
Data bits
ADIS16203
Table 23. GPIO_CTRL Bit Descriptions
GENERAL-PURPOSE I/O CONTROL
As previously noted, the ADIS16203 provides two general-purpose,
bidirectional I/O pins (GPIOs) that are available to the user for control
of auxiliary circuits within the target application. All I/O pins are 5 V
tolerant, meaning that the GPIOs support an input voltage of 5 V. Each
GPIO pin has an internal pull-up resistor of approximately 100 kΩ
and a drive capability of 1.6 mA. The direction, as well as the logic
level, can be controlled for these GPIO pins through the GPIO_CTRL
control register, as defined in Table 23.
These same GPIO pins are also controllable through the ALM_CTRL
and MSC_CTRL control registers. The priority for these three control
registers in controlling the two GPIO pins is MSC_CTRL has precedence over ALM_CTRL, which has precedence over GPIO_CTRL.
Bit
15:10
9
8
7:2
1
0
GPIO_CTRL Register Definition
Address
0x33, 0x32
1
Default1
0x0000
Format
N/A
Access
R/W
Default is valid only until the first register write cycle.
The data within the general-purpose digital I/O control register is
volatile and is set to 0s upon reset.
Rev. 0 | Page 23 of 28
Description
Not used
General-Purpose I/O Line 0, Data Direction Control
0: Input
1: Output
General-Purpose I/O Line 1, Data Direction Control
0: Input
1: Output
Not used
General-Purpose I/O Line 0 Polarity
0: Low
1: High
General-Purpose I/O Line 1 Polarity
0: Low
1: High
ADIS16203
APPLICATIONS
HARDWARE CONSIDERATIONS
SELF-TEST TIPS
The ADIS16203 can be operated from a single 3.3 V (3.0 V to 3.6 V)
power supply. The ADIS16203 integrates two decoupling capacitors
that are 1 μF and 0.1 μF in value. For the local operation of the
ADIS16203, no additional power supply decoupling capacitance is
required.
When using the ADIS16203’s self-test function to monitor
incline angles around 0°, using the INCL_180_OUT register is
more convenient than using the INCL_OUT register. Because
the measurements in the INCL_OUT register jump from 0 to
359.975, they may trigger false alarms. The same philosophy
can be applied to monitoring conditions around 180°. Because
the INCL_OUT provides continuous measurements through
180° and the INCL_180_OUT abruptly changes from −180° to
+180°, the INCL_OUT register is a more convenient choice.
However, if the system power supply presents a substantial amount
of noise, additional filtering may be required. If additional capacitors
are required, connect the ground terminal of each capacitor directly
to the underlying ground plane. Finally, note that all analog and
digital grounds should be referenced to the same system ground
reference point.
GROUNDING AND BOARD LAYOUT
RECOMMENDATIONS
Maintaining low impedance signal return paths can be very critical
in managing system-level noise effects. For best results, use a single,
continuous ground plane that is tied to each ADIS16203 ground pin
via short trace lengths. In addition to maintaining a low impedance
ground structure, routing the SPI signals away from sensitive analog
circuits, such as the ADC and DACs (if they are in use), can help
mitigate system-level noise risks.
BAND GAP REFERENCE
The ADIS16203 provides an on-chip band gap reference of
2.5 V that is utilized by the on-board ADC and DAC. This
internal reference also appears on the VREF pin. This reference
can be connected to external circuits in the system. An external
buffer would be required because of the low drive capability of
the VREF output.
Rev. 0 | Page 24 of 28
ADIS16203
POWER-ON RESET OPERATION
Table 24.
An internal power-on reset (POR) is implemented internally to
the ADIS16203. For VDD below 2.35 V, the internal POR holds the
ADIS16203 in reset. As VDD rises above 2.35 V, an internal timer
times out for typically 130 ms before the part is released from reset.
The user must ensure that the power supply has reached a stable
3.0 V minimum level by this time. Likewise, on power-down, the
internal POR holds the ADIS16203 in reset until VDD drops below
2.35 V. Figure 33 illustrates the operation of the internal POR in detail.
Profile Feature
Average Ramp Rate (TL to TP)
Preheat
Minimum Temperature
(TSMIN)
Maximum Temperature (TSMAX)
Time (TSMIN to TSMAX) (ts)
2.35V TYP
VDD
06108-029
130ms TYP
POR
TSMAX to TL
Ramp-Up Rate
Time Maintained Above
Liquidous (TL)
Liquidous Temperature (TL)
Time (tL)
Figure 33. Internal Power-On Reset Operation
Peak Temperature (TP)
Once the power sequence is complete, the self-test sequence follows.
This sequence takes approximately 14 ms in high performance mode
and approximately 36 ms in normal mode. The power-up self-test
can be disabled using Bit 10 in the MSC_CTRL register if the start
time is a critical consideration.
Time Within 5°C of Actual
Peak Temperature (tp)
Ramp-Down Rate
Time 25°C to Peak Temperature
Condition
Sn63/Pb37
Pb-Free
3°C/sec max
3°C/sec max
100°C
150°C
150°C
60 sec to
120 sec
200°C
60 sec to
150 sec
3°C/sec
3°C/sec
183°C
60 sec to
150 sec
240°C +
0°C/–5°C
10 sec to
30 sec
6°C/sec max
6 minutes
max
217°C
60 sec to
150 sec
260°C +
0°C/–5°C
20 sec to
40 sec
6°C/sec max
8 minutes
max
SECOND-LEVEL ASSEMBLY
TSMIN
tS
RAMP-DOWN
PREHEAT
t25°C TO PEAK
TIME
06108-030
TEMPERATURE
tL
TSMAX
0.670 BSC
(12 PLCS)
7.873 BSC
(2 PLCS)
1.127 BSC
(16 PLCS)
Figure 35. Example Pad Layout
RAMP-UP
TL
1.178 BSC
(8 PLCS)
0.500 BSC
(16 PLCS)
CRITICAL ZONE
TL TO TP
tP
TP
EXAMPLE PAD LAYOUT
Figure 34. Acceptable Solder Reflow Profiles
Rev. 0 | Page 25 of 28
06108-031
The ADIS16203 can be attached to the second-level assembly board
using SN63 (or equivalent) or lead-free solder. Figure 34 and Table 24
provide acceptable solder reflow profiles for each solder type. Note
that these profiles may not be the optimum profile for the user’s
application. In no case should 260°C be exceeded. It is recommended
that the user develop a reflow profile based upon the specific application.
In general, the lowest peak temperature and shortest dwell time above
the melt temperature of the solder result in less shock and stress to
the product. In addition, evaluating the cooling rate and peak temperature can result in a more reliable assembly.
ADIS16203
OUTLINE DIMENSIONS
1.405
BSC
9.327 MAX
SQ
A1 CORNER
INDEX AREA
16
13
12
1
0.797
BSC
1.00
BSC
4
9
5
8
TOP VIEW
BOTTOM VIEW
0.227 BSC
(4 PLCS)
0.373 BSC
(16 PLCS)
5.00 TYP
030906-A
3.90
MAX
SIDE VIEW
Figure 36. 16-Terminal Land Grid Array [LGA]
(CC-16-2)
Dimensions shown in millimeters
ORDERING GUIDE
Model
ADIS16203CCCZ 1
ADIS16203/PCBZ1
1
Temperature Range
−40°C to +125°C
Package Description
16-Terminal Land Grid Array [LGA]
Evaluation Board
Z = Pb-free part.
Rev. 0 | Page 26 of 28
Package Option
CC-16-2
ADIS16203
NOTES
Rev. 0 | Page 27 of 28
ADIS16203
NOTES
©2006 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D06108-0-8/06(0)
Rev. 0 | Page 28 of 28
Similar pages