Constant voltage LED Drivers For outdoor use LEA-18V Series, 18Watt FEATURES: Constant voltage output Input voltage: 90-132VAC Short circuit, over voltage, and over temperature protections IP67 rated Class , no FG Pass LPS (Limited Power Source) Test Application for LED lighting and electronic screen 100% burn-in test High reliability 2 years warranty Cooling by free air convection Ⅱ Model Input voltage (Vac) LEA18-V12 LEA18-V24 90-132 LEA18-V36 Output voltage (Vdc) Output current (mA) Output power (W) Min. Max. 12 0 1500 18 24 0 750 18 36 0 500 18 ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input voltage Vin --- 90 -- 132 Vac Input frequency Fline --- 47 -- 63 Hz Input current Iin Full load, Vin =115Vac -- 0.5 -- A Inrush current Iinrush Cold start, Vin =115Vac -- 40 -- A η Full load -- 82 -- % Ileakage Vin =115Vac -- 0.25 -- mA Efficiency Leakage current www.pairuigroup.com Page: 1 / 4 Date: 01/25/2014 Constant voltage LED Drivers For outdoor use LEA-18V Series, 18Watt ELECTRICAL Output Parameters Test Conditions / Comment Min. Typ. Max. Units LEA18-V12 0 -- 1500 mA LEA18-V24 0 -- 750 mA LEA18-V36 0 -- 500 mA LEA18-V12 -- 12 -- V LEA18-V24 -- 24 -- V LEA18-V36 -- 36 -- V -- --- -- ±3 -- % Line regulation Iout-line --- -- ±1.0 -- % Load regulation Iout-load --- -- ±2.0 -- % Turn-on delay time Ton_delay Vin =115Vac, full load -- 1500 -- ms Ton_rise Vin =115Vac, full load -- 30 -- ms Hold-on time -- Vin =115Vac, full load -- 20 -- ms Ripple -- --- -- -- 200 mVp-p Output current Output voltage Output voltage accuracy Rise time Symbols Iout Vout Protection Over current Typical:>105%.Hiccup mode, it will auto-recovery after fault conditions remove Over voltage Typical:110-150%; Protection: turn off output voltage, Diode clamp type Over temperature Hiccup mode, it will auto-recovery after temperature become normal Environment Storage Ambient operating temperature Temperature coefficient www.pairuigroup.com Tstorage Ta -- Humidity: 5% RH to 95% RH Startup at rated voltage (Please refer to derating curve) --- Page: 2 / 4 -40 -- +80 ℃ -30 -- +70 ℃ -- 300 -- ppm Date: 01/25/2014 Constant voltage LED Drivers For outdoor use LEA-18V Series, 18Watt ELECTRICAL Environment Parameters Operating relative humidity MTBF Symbols Test Conditions / Comment Min. Typ. Max. Units Ha Non condensing 10 -- 95 % -- 1200.5 -- kHrs TMTBF Full load, 115Vac input, ℃ 25 ambient temperature Dimension(LxWxH) 140x30x22mm Weight 175g Safety / EMC Safety standards UL1310 Class 2, TUV EN60950-1, EN61347-2-13,IP67 Withstand voltage I/P-O/P:3KVAC Insulation resistance I/P-O/P: EMC emission Design to EN55022(CISPR22)Class B, EN61000-3-2 Class A, EN61000-3-3 EMC immunity Design to EN61000-4-2,3,4,5,6,8,11, EN55024 >100M Ohms/500VDC/25℃/70%RH ℃ Notes: 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and Vin = 115Vac, rated load; 2. Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor; 3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes. MECHANICAL Unit: mm www.pairuigroup.com Page: 3 / 4 Date: 01/25/2014 Constant voltage LED Drivers For outdoor use LEA-18V Series, 18Watt MECHANICAL RECOMMEND INSTALLATION BLOCK DIAGRAM DERATING CURVE STATIC CHARACTERISTIC CURVE 100 90 80 Load ) % 70 ( 60 50 40 30 90 100 110 120 132 140 Input voltage ( Vac ) at 60Hz www.pairuigroup.com Page: 4 / 4 Date: 01/25/2014