XTAL AXHV6006 Vco - voltage controlled oscillator in to-8 package Datasheet

Issue: 01
Date: 2005-12-08
Specification
AXHV6006
Oscillator type :
VCO – Voltage Controlled Oscillator in TO-8 package
Parameter
min.
typ.
max.
Unit
Condition
9900
11700 MHz
@ 25°C
Frequency tuning range
Frequency adjustment range
EFC voltage VC
0
20
V
40
140
MHz/V
Tuning sensitivity (∆f / ∆VC)
EFC slope
positive
RF output
Signal waveform
SINUS
Amplitude
+6
+11
dBm
RL = 50 Ω
Harmonics
-15
dBc
-85
dBc/Hz @ 100 kHz
Phase Noise
Supply voltage VS
4.75
5
5.25
V
Current consumption (steady state)
100
mA
-40
+85
°C
Operating temperature range
-45
+90
°C
Operable temperature range
-55
+95
°C
Storage temperature range
12.7 Ø x 5.5
mm
“TO-8”
Enclosure (see drawing) DiameterxH
5
gram
Weight
bulk
IEC 60286-3
Packing
1500
V
HBM, IEC 61000-4-2
ESD Sensitivity
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Ordering Code:
Model (Specification)
AXHV6006
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Frequency Range [MHz]
9900-11700
AXHV6006
page 1(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Pin connections
Enclosure drawing
Pin #
1
2
3
4
Symbol
RF OUT
VS
VC
GND
Function
RF Output
Supply Voltage (Bias)
Control Voltage (EFC)
Ground
bottom view
Typical Performance
HV6006
f/GHz
12
11,5
11
10,5
10
9,5
0
5
10
15
20
Vtune/V
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXHV6006
page 2(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Sensivity(MHz/V)
HV6006
200
150
100
50
0
0
5
10
15
20
Vtune/V
HV6006
Pout/dBm
15
10
5
0
0
5
10
15
20
Vtune/V
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXHV6006
page 3(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXHV6006
page 4(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Similar pages