Lineage Power CAR1612FPY0-1A 1600 watt 12v front end power supply Datasheet

CAR1612FP Series
1600 Watt +12V Front End Power Supply
by Lineage Power
Features:
∎ Compact 1U Profile
∎ High Efficiency design optimized for mid to light load applications
∎ Constant Current Characteristic
∎ N+1 Redundancy with Hot Plug Capability
∎ High Power Density (20W/in3)
∎ 3.3VSB, Active Load Sharing, I²C and PMBus standard Interface
∎ Remote On/Off and Remote Sense functions
PLATINUM
FEATURES
High Power Density 20W/in3
Load Sharing & Fault Tolerant
Automatic Fan Speed Control
System Scalability up to 6.4kW
Universal Input & International
Certifications
BENEFITS
More system space for application circuits and hardware
Excellent reliability in N+1 operation
Reduces audible noise and increases reliability
Allows flexibility with minimum investment
Reduces logistical costs
SPECIFICATIONS
Input Voltage Range
Input Current Maximum
Inrush Current
Input Protection
Power Factor
Efficiency
Output Power
Output Voltage Range
Output Current
Standby Bias Voltage
Voltage Regulation
Output Ripple & Noise
Transient Response
Hold-Up Time
Remote On/Off
Current Limit Protection
Short Circuit Protection
Over Voltage Protection
Operating Temperature
Over Temperature Protection
EMI
LED Indicators
Analog Status & Control
1600 Watt +12V Front End Power Supply
85-264 VAC, 47-63 Hz, derate to 1200W for <180VAC Input
10.5A @ 180VAC / 14.3A @ 100VAC, Full Load (max)
40A max. cold start (per ETS 300 132-1 and Bellcore specifications)
20 Amp / 250 VAC
0.99 typical at full load, complies with IEC555, EN60555-2, EN61000-3-2
Up to 94.5% at 50% Load and 230VAC Operation
1600W at High Line Operation (180-264 VAC), 1200W at Low Line Operation (85-132 VAC)
10.8~13.2 VDC with remote programming
134A @ 12Vout / 230VAC Operation, 100A @ 12Vout / 110VAC Operation
3.3VSB@1A (optional 5Vsb)
±2% of Vnom for any combination of line, load and temperature
1% (pk-pk) @ 20MHz with 0.1µF ceramic and 10µF Tantalum caps at the output
5% max deviation Recovery time 300μs @ 50% load step and di/dt < 1A/μs
12ms at 1600W (typical) @ 220Vac (Early Warning: 2ms)
ON if >3V or open; OFF if <1V (max. sink 1mA) Open collector type
Adjustable via I²C interface or PMBus, Constant current characteristic & power limited to 1600W or 1200W (<180VAC input)
Self protected with auto recovery
Trip level >+14.8Vdc ± 1V, Reset condition by recycling the AC input or applying Remote ON/OFF
-10°C to +70°C. power derating above 50°C at 2.5%/°C
Non-Latching, thermal shutdown point is set for 125°C and recovery point is 110°C
FCC-B & EN55022-B with specified filter or at rack level, GR-1089-CORE
AC OK (Green) / DC OK (Green) / Thermal Alarm (Orange) / Fault (Red), “All on one LED” Tri-color LED
Voltage Programming (V Prog), Load sharing (I Share), Remote On/Off, Current Monitor (I Monitor), AC OK, DC OK,
Temperature Warning, Fault, PS Present, Module Enable,
I2C Option and PMBus Option, see detailed specification for details
NEBS GR-63-CORE Level 3
12.45 x 4.00 x 1.61” / 316.23 x 101.6 x 41.91mm
4.28 lb. / 1.94 kg.
IEC/UL/CSA/EN60950-1, CE Mark (LVD), TUV
5VSB Output, Bezel
Digital Status & Control
Shock & Vibration
Dimensions
Weight
Safety Approvals
Options
KEY MARKET SEGMENTS & APPLICATIONS
∎ Distributed Power
∎ Blade Servers
∎ Mid-End Servers
∎ Network Equipment
∎ Network Attached Storage
∎ Storage Area Networks
www.LineagePower.com
Lineage Power
Lineage Power
Lineage Power (China)
3000 Skyline Dr.
Mesquite, TX 75149
2841 Dow Avenue
Tustin, CA 92780 USA
1353 Chenqiao Road, Shanghai Sengpu Industrial Park
Shanghai, 201401 China
P: 021 6710 8910
rev 100603
P: (972) 284-2000
F: (972) 284-2000
P: (714) 544-6665
F: (714) 838-4742
CAR1612FP Series
1600 Watt +12V Front End Power Supply
by Lineage Power
OUTLINE DRAWING
All Dimensions in Inches (mm)
Tolerance: .XX = ± .02 in (.50 mm)
.XXX = ± .010 in (.254 mm)
EFFICIENCY CURVE:
CONNECTOR DRAWING:
94.5%
95%
94.5%
94.0%
93.4%
92.4%
93%
92.5%
D1 D2 D3 D4 D5 D6
Efficiency %
91%
89%
P1
88.5%
P2
P3
P4
P5
P6
P7
P8
87%
C1 C2 C3 C4 C5 C6
B1 B2 B3 B4 B5 B6
A1 A2 A3 A4 A5 A6
85%
83%
81%
FCI Berg Pt # 51732-021 or equivalent
Suggested mating connector part # 51762-10802400ABLF (Right Angle Mounting)
79%
10%
20%
40%
50%
60%
80%
100%
% of Load @ 230Vac
PART NUMBER DEFINITION GUIDE:
CAR 16 12 F P x xx -1A
Series
16=1600W
Output Current
12=12V
Output Voltage
F=Front End
Type
P=Positive
Polarity
Example:
Rev.
Blank=Non-compliant
YO=5 of 6 Compliant
ZO=6 of 6 Compliant
RoHS
B=Bezel Option
Blank=None
Options
CAR1612FPBZ0-1A
1600W/12V Front End, Bezel, 6 of 6 RoHS
PIN OUT INFORMATION
A1
VSB 3.3V
B4
PS Present
D1
V Prog
P4
Vout Return
A2
VSB 3.3V Return
B5
SDA
D2
OVP Test Point
P5
Vout
A3
Signal RTN
B6
SCL
D3
Remote On/Off
P6
Vout
A4
Write Protect
C1
I Share
D4
DC OK
P7
Vout
P8
Vout
A5
Remote Sense (+)
C2
Not Connected
D5
AC OK
A6
Remote Sense (-)
C3
Temp Warning
D6
Interrupt
B1
Fault
C4
I2C Address (A0)
P1
Vout Return
B2
I Monitor
C5
I2C Address (A1)
P2
Vout Return
B3
Enable (Short Pin)
C6
I2C Address (A2)
P3
Vout Return
www.LineagePower.com
Lineage Power
Lineage Power
Lineage Power (China)
3000 Skyline Dr.
Mesquite, TX 75149
2841 Dow Avenue
Tustin, CA 92780 USA
1353 Chenqiao Road, Shanghai Sengpu Industrial Park
Shanghai, 201401 China
P: 021 6710 8910
rev 100603
P: (972) 284-2000
F: (972) 284-2000
P: (714) 544-6665
F: (714) 838-4742
Similar pages