XP Power ECP20US05 Pcb mount Datasheet

AC-DC
20 Watts
xppower.com
ECP20 Series
•
Low Profile, 0.73”
•
Class II Construction
•
PCB Mounting
•
Single Outputs from 3.3 to 48 V
•
Dual Outputs from 12 to 24 V
•
<0.3 W No Load Input Power
•
Peak Load Capability
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
General
•
•
•
•
•
•
85-264 VAC
47-63 Hz
0.5 A max at 115 VAC
40 A max at 230 VAC
Conforms to EN61000-3-2, Class A
<0.3 W
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
Ripple & Noise
•
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
See table
±1% at 60% load
No minimum load required
1.3 s max
15 ms typical
10 ms min at full load & 115 VAC
±0.5% max
±1.0% max
4% max deviation, recovering to less than
1% within 500us for 50% step load
change at 1 A/µs
3.3 & 5 V versions: 50 mV, 1% for others
measured with 20 MHz BW
110-140% of nominal output voltage
150-180% of full load current
Trip and restart (Hiccup mode)
0.02%/°C max
Output
Efficiency
Isolation
Switching Frequency
• See tables
• 3000 VAC Input to Output
• 65 kHz typical
Environmental
Operating Temperature • 0 °C to +70 °C, derate from 100% load at
50 °C to 50% load at 70 °C
Cooling
• Natural convection
Operating Humidity
• 5% to 95% RH, non condensing
Storage Temperature
• -40 °C to +85 °C
Shock
• 30g, half sine, 6 axis
Vibration
• 5-50 Hz, 2g 15 mins/sweep, 30 mins for
each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
•
•
•
•
Radiated Immunity
EFT / Burst
Surge
Conducted Immunity
Dips & Interruptions
•
•
•
•
•
Safety Approvals
•
EN55022, level B conducted & radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2, ±4 kV indirect contact,
Perf Criteria A
EN61000-4-3, 3 V/m, Perf Criteria A
EN61000-4-4, level 2 Perf Criteria A
EN61000-4-5, level 2 Perf Criteria A
EN61000-4-6, 3 V Perf Criteria A
EN61000-4-11, 70% UT 10ms, 40% UT
100ms, <5% UT 5000ms,
Perf Criteria A, B, B
EN60950, cUL60950, IEC60950-1
Output
Power
Output 1
Voltage
Current
Output 2
Peak
Voltage
(1)
Current
Peak
(1)
Efficiency
Model
Number(2)
13.2 W
3.3 VDC
4.0 A
5.20 A
75%
ECP20US03
20 W
5.0 VDC
4.0 A
5.20 A
80%
ECP20US05
20 W
9.0 VDC
2.23 A
2.90 A
82%
ECP20US09
20 W
12.0 VDC
1.67 A
2.17 A
84%
ECP20US12
20 W
15.0 VDC
1.34 A
1.74 A
84%
ECP20US15
20 W
24.0 VDC
0.84 A
1.09 A
85%
ECP20US24
20 W
30.0 VDC
0.67 A
0.87 A
86%
ECP20US30
20 W
48.0 VDC
0.42 A
0.55 A
87%
ECP20US48
20 W
+12.0 VDC
0.84 A
1.09 A
-12.0 VDC
0.84 A
1.09 A
83%
ECP20UD12
20 W
+15.0 VDC
0.67 A
0.87 A
-15.0 VDC
0.67 A
0.97 A
84%
ECP20UD15
20 W
+24.0 VDC
0.42 A
0.55 A
-24.0 VDC
0.42 A
0.55 A
84%
ECP20UD24
Notes
1. Peak load lasting <30 s with a maxiumum duty cycle of 10%, average output power not to exceed nominal.
Mechanical Details
4
0.45
(11.50)
0.157 (4.0)
5
0.492
(12.50)
1
0.79 (20)
1.57 (40)
0.45
(11.50)
3
2
0.1 (2.5)
2.44 (62)
0.55 (14)
2.64 (67)
ø 0.080 (ø2.00)
0.15 (3.80)
ø 0.040 (ø1.00)
Pin
ECP20US
1
Line
Line
2
Neutral
Neutral
3
Output -VE
Output -VE
4
Not Connected
Common
5
Output +VE
Output +VE
0.10 (2.60)
0.12 (3)
0.06 (1.60)
ECP20UD
Notes
1. All measurements are in inches (mm).
2. Weight: 40g approx.
27-Nov-08
AC-DC
ECP20
Models and Ratings
Similar pages