IXYS LBA127S Dual single-pole, combination optomos relay Datasheet

LBA127
Dual Single-Pole, Combination
OptoMOS® Relay
INTEGRATED CIRCUITS DIVISION
Parameter
Blocking Voltage
Load Current
On-Resistance (max)
Ratings
250
200
10
Units
VP
mArms / mADC

Features
• 3750Vrms Input/Output Isolation
• Low Drive Power Requirements
(TTL/CMOS Compatible)
• High Reliability
• Arc-Free With No Snubbing Circuits
• FCC Compatible
• VDE Compatible
• No EMI/RFI Generation
• Small 8-Pin Package
• Machine Insertable, Wave Solderable
• Surface Mount, Tape & Reel Version Available
Description
LBA127 is a combination device comprising one
normally open (1-Form-A) and one normally
closed (1-Form-B) solid state relay. Both relays are
independent, 250V, 200mA, 10 devices designed to
provide an ideal solution where a complementary relay
pair (1-Form-A / 1-Form-B) is required.
Approvals
• UL Recognized Component: File E76270
• CSA Certified Component: Certificate 1175739
• EN/IEC 60950-1 Certified Component:
TUV Certificate B 09 07 49410 004
Ordering Information
Applications
• Telecommunications
• Telecom Switching
• Tip/Ring Circuits
• Modem Switching (Laptop, Notebook, Pocket Size)
• Hook Switch
• Dial Pulsing
• Ground Start
• Ringing Injection
• Instrumentation
• Multiplexers
• Data Acquisition
• Electronic Switching
• I/O Subsystems
• Meters (Watt-Hour, Water, Gas)
• Medical Equipment-Patient/Equipment Isolation
• Security
• Aerospace
• Industrial Controls
Part #
LBA127
LBA127P
LBA127PTR
LBA127S
LBA127STR
Description
8-Pin DIP (50/Tube)
8-Pin Flatpack (50/Tube)
8-Pin Flatpack (1000/Reel)
8-Pin Surface Mount (50/Tube)
8-Pin Surface Mount (1000/Reel)
Pin Configuration
+ Control - Normally Closed
– Control - Normally Closed
+ Control - Normally Open
– Control - Normally Open
1
8
2
7
3
6
4
5
Switching Characteristics of
Normally Open
(Form A) Devices
Switching Characteristics of
Normally Closed
(Form B) Devices
IF
IF
ILOAD
90%
ILOAD
ton
DS-LBA127-R12
Normally Open Pole
Form-B
Form-A
Pb
Normally Closed Pole
90%
10%
10%
toff
toff
ton
e3
www.ixysic.com
1
INTEGRATED CIRCUITS DIVISION
LBA127
Absolute Maximum Ratings @ 25°C
Parameter
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
1
2
Ratings
250
5
50
1
150
800
3750
-40 to +85
-40 to +125
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Units
VP
V
mA
A
mW
mW
Vrms
°C
°C
Derate linearly 1.33 mW / °C
Derate linearly 6.67 mW / °C
Electrical Characteristics @ 25°C
Parameter
Output Characteristics
Load Current
Continuous 1
Peak
On-Resistance 2
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Input Characteristics
Input Control Current to Activate
Input Control Current to Deactivate
Input Voltage Drop
Reverse Input Current
Common Characteristics
Input to Output Capacitance
2
Conditions
Symbol
Min
Typ
Max
Units
t = 10ms
IL=200mA
VL=250VP
IL
ILPK
RON
ILEAK
-
6.8
-
200
±400
10
1
mArms / mADC
mAP

VL=50V, f=1MHz
ton
toff
COUT
-
110
5
5
-
IL=200mA
IF=5mA
VR=5V
IF
IF
VF
IR
0.4
0.9
-
0.7
1.2
-
5
1.4
10
mA
mA
V
A
-
CI/O
-
3
-
pF
IF=5mA, VL=10V
1
If both poles operate simultaneously, then the load current must be derated so as not to exceed the package power dissipation value.
2
Measurement taken within 1 second of on-time.
www.ixysic.com
A
ms
pF
R12
INTEGRATED CIRCUITS DIVISION
LBA127
Form-A/Form-B PERFORMANCE DATA @25ºC (Unless Otherwise Noted)*
25
25
20
15
10
5
20
15
10
5
20
15
10
0
0
1.18
1.20
1.22
1.24
5
0
0.35
1.26
0.40
0.45
0.50
0.55
0.60
332
334
336
338
340
342
LED Forward Voltage Drop (V)
LED Current (mA)
Blocking Voltage (VP)
Typical LED Forward Voltage Drop
vs. Temperature
Typical IF for Switch Operation
vs. Temperature
(IL=100mADC)
Typical Blocking Voltage
vs. Temperature
(Form-A: IF=0mA, Form-B: IF=5mA)
0.65
1.6
IF=50mA
IF=20mA
IF=10mA
1.5
1.4
1.3
1.2
IF=5mA
0.60
0.55
0.50
1.1
0.45
1.0
-40
0.40
-40
0
20
40
60
Temperature (ºC)
Load Current (mA)
250
80
100
-20
0
20
40
60
Temperature (ºC)
Load Current vs. Load Temperature
(Form-A: IF=5mA, Form-B: IF=0mA)
100
340
335
330
325
320
315
-40
-20
0
20
40
60
80
100
Temperature (ºC)
Energy Rating Curve
1.0
200
150
100
50
0.8
0.6
0.4
0.2
0
-40
80
345
1.2
Load Current (A)
-20
355
350
LED Current (mA)
LED Forward Voltage Drop (V)
25
Device Count (N)
Device Count (N)
Device Count (N)
30
Typical Blocking Voltage Distribution
(Form-A: IF=0mA, Form-B: IF=5mA)
(N=50)
Typical IF for Switch Operation
(N=50, IL=200mADC)
Blocking Voltage (VP)
35
Typical LED Forward Voltage Drop
(N=50, IF=5mA)
-20
0
20
40
60
Temperature (ºC)
80
100
0
10Ps 100Ps 1ms 10ms 100ms
1s
10s
100s
Time
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
R12
www.ixysic.com
3
INTEGRATED CIRCUITS DIVISION
LBA127
Form-A RELAY PERFORMANCE DATA @25ºC (Unless Otherwise Noted)*
Form-A
Typical Turn-On Time
(N=50, IF=5mA, IL=200mADC)
25
15
10
5
0
20
15
10
5
0.33
0.36
0.39
0.42
0.45
0.12
0.13
Turn-On Time (ms)
Form-A
Typical Turn-On Time
vs. Temperature
(IF=5mA, IL=100mADC)
1.2
0.14
0.15
0.16
Turn-Off Time (ms)
0.4
0.2
-40
-20
0
20
40
60
Temperature (ºC)
80
100
Form-A
Typical Turn-On Time
vs. LED Forward Current
(IL=100mADC)
1.00
5
6.75
6.80
6.85
6.90
6.95
Form-A
Typical On-Resistance vs. Temperature
(IF=5mA, IL=100mADC)
8.5
8.0
0.16
0.14
0.12
0.10
7.5
7.0
6.5
6.0
5.5
0.08
-40
0
10
On-Resistance (:)
On-Resistance (:)
Turn-Off Time (ms)
0.6
15
6.70
0.18
0.8
20
0.17
Form-A
Typical Turn-Off Time
vs. Temperature
(IF=5mA, IL=100mADC)
0.20
1.0
Form-A
Typical On-Resistance Distribution
(N=50, IF=5mA, IL=200mADC)
0
0
0.30
Turn-On Time (ms)
25
Device Count (N)
20
Device Count (N)
Device Count (N)
25
Form-A
Typical Turn-Off Time
(N=50, IF=5mA, IL=200mADC)
-20
0
20
40
60
Temperature (ºC)
80
5.0
-40
100
Form-A
Typical Turn-Off Time
vs. LED Forward Current
(IL=100mADC)
0.165
0.20
-20
0
20
40
60
Temperature (ºC)
80
100
Form-A
Typical Load Current vs. Load Voltage
(IF=5mA)
0.50
0.25
Load Current (A)
Turn-Off Time (ms)
Turn-On Time (ms)
0.15
0.75
0.160
0.155
0.10
0.05
0.00
-0.05
-0.10
-0.15
0.150
0
0
10
20
30
40
LED Forward Current (mA)
50
0
10
20
30
40
LED Forward Current (mA)
50
-0.20
-1.5
-1.0
-0.5
0.0
0.5
Load Voltage (V)
1.0
1.5
Form-A
Typical Leakage vs.Temperature
(Measured Across Pins 5 & 6)
(VL=250V)
0.025
Leakage (PA)
0.020
0.015
0.010
0.005
0.000
-40
-20
0
20
40
60
Temperature (ºC)
80
100
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
4
www.ixysic.com
R12
INTEGRATED CIRCUITS DIVISION
LBA127
Form-B RELAY PERFORMANCE DATA @25ºC (Unless Otherwise Noted)*
Form-B
Typical Turn-On Time
(N=50, IF=5mA, IL=200mADC)
25
15
10
5
20
15
10
5
15
10
5
0.05
0.20
0.07
0.09
0.11
0
0.75
0.13
1.25
1.75
2.25
2.75
3.25
4.05
4.95
5.25
5.55
On-Resistance (:)
Form-B
Typical Turn-On Time
vs. Temperature
(IF=5mA, IL=100mADC)
Form-B
Typical Turn-Off Time
vs. Temperature
(IL=100mADC)
Form-B
Typical On-Resistance vs. Temperature
(IF=0mA, IL=100mADC)
3.5
Turn-Off Time (ms)
3.0
0.10
0.05
2.5
9
IF=5mA
8
IF=10mA
7
IF=20mA
2.0
1.5
1.0
0.5
-20
78.5
4.65
Turn-Off Time (ms)
0.15
0
-40
4.35
Turn-On Time (ms)
On-Resistance (:)
0.03
Form-B
Typical On-Resistance Distribution
(N=50, IF=0mA, IL=200mADC)
20
0
0
Turn-On Time (ms)
25
Device Count (N)
20
Device Count (N)
Device Count (N)
25
Form-B
Typical Turn-Off Time
(N=50, IF=5mA, IL=200mADC)
0
20
40
60
80
5
4
3
2
1
0
-40
100
6
-20
0
20
40
80
60
0
-40
100
-20
0
20
40
60
80
100
Temperature (ºC)
Temperature (ºC)
Temperature (ºC)
Form-B
Typical Turn-On Time
vs. LED Forward Current
(IL=100mADC)
Form-B
Typical Turn-Off Time
vs. LED Forward Current
(IL=100mADC)
Form-B
Typical Load Current vs. Load Voltage
(IF=0mA)
2.5
200
77.5
77.0
76.5
2.0
Load Current (mA)
Turn-Off Time (ms)
Turn-On Time (Ps)
150
78.0
1.5
1.0
0.5
100
50
0
-50
-100
-150
0
76.0
0
5
10
15
20
25
30
35
40
45
-200
0
50
5
10
15
20
25
30
35
40
45
50
LED Forward Current (mA)
LED Forward Current (mA)
0.06
-1 -0.8 -0.6 -0.4 -0.2
0
0.2 0.4 0.6 0.8
1
Load Voltage (V)
Form-B
Typical Leakage vs. Temperature
Measured Across Pins 7&8
(IF=5mA)
Leakage (PA)
0.05
0.04
0.03
0.02
0.01
0
-40
-20
0
20
40
60
Temperature (ºC)
80
100
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
R12
www.ixysic.com
5
INTEGRATED CIRCUITS DIVISION
LBA127
Manufacturing Information
Moisture Sensitivity
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated
Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to
the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product
evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper
operation of our devices when handled according to the limitations and information in that standard as well as to any
limitations set forth in the information or standards referenced below.
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced
product performance, reduction of operable life, and/or reduction of overall reliability.
This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according
to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.
Device
Moisture Sensitivity Level (MSL) Rating
LBA127 / LBA127S / LBA127P
MSL 1
ESD Sensitivity
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.
Reflow Profile
This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020
must be observed.
Device
Maximum Temperature x Time
LBA127 / LBA127S
250ºC for 30 seconds
LBA127P
260ºC for 30 seconds
Board Wash
IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to
remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as
an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary
if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used.
Cleaning methods that employ ultrasonic energy should not be used.
Pb
6
e3
www.ixysic.com
R12
INTEGRATED CIRCUITS DIVISION
LBA127
MECHANICAL DIMENSIONS
LBA127
2.540 ± 0.127
(0.100 ± 0.005)
9.652 ± 0.381
(0.380 ± 0.015)
8-0.800 DIA.
(8-0.031 DIA.)
2.540 ± 0.127
(0.100 ± 0.005)
9.144 ± 0.508
(0.360 ± 0.020)
6.350 ± 0.127
(0.250 ± 0.005)
Pin 1
PCB Hole Pattern
7.620 ± 0.254
(0.300 ± 0.010)
6.350 ± 0.127
(0.250 ± 0.005)
3.302 ± 0.051
(0.130 ± 0.002)
0.457 ± 0.076
(0.018 ± 0.003)
7.620 ± 0.127
(0.300 ± 0.005)
7.239 TYP.
(0.285)
4.064 TYP
(0.160)
7.620 ± 0.127
(0.300 ± 0.005)
0.254 ± 0.0127
(0.010 ± 0.0005)
Dimensions
mm
(inches)
0.813 ± 0.102
(0.032 ± 0.004)
LBA127S
9.652 ± 0.381
(0.380 ± 0.015)
2.540 ± 0.127
(0.100 ± 0.005)
6.350 ± 0.127
(0.250 ± 0.005)
Pin 1
0.635 ± 0.127
(0.025 ± 0.005)
3.302 ± 0.051
(0.130 ± 0.002)
9.525 ± 0.254
(0.375 ± 0.010)
0.457 ± 0.076
(0.018 ± 0.003)
PCB Land Pattern
2.54
(0.10)
8.90
(0.3503)
1.65
(0.0649)
7.620 ± 0.254
(0.300 ± 0.010)
0.254 ± 0.0127
(0.010 ± 0.0005)
0.65
(0.0255)
4.445 ± 0.127
(0.175 ± 0.005)
Dimensions
mm
(inches)
0.813 ± 0.102
(0.032 ± 0.004)
LBA127P
2.540 ± 0.127
(0.100 ± 0.005)
6.350 ± 0.127
(0.250 ± 0.005)
0 MIN / 0.102 MAX
(0 MIN / 0.004 MAX)
9.398 ± 0.127
(0.370 ± 0.005)
Pin 1
9.652 ± 0.381
(0.380 ± 0.015)
7.620 ± 0.254
(0.300 ± 0.010)
2.286 MAX.
(0.090 MAX.)
2.54
(0.10)
0.635 ± 0.127
(0.025 ± 0.005)
0.203 ± 0.013
(0.008 ± 0.0005)
8.70
(0.3425)
1.55
(0.0610)
0.65
(0.0255)
2.159 ± 0.025
(0.085 ± 0.001)
0.457 ± 0.076
(0.018 ± 0.003)
0.864 ± 0.120
(0.034 ± 0.004)
R12
PCB Land Pattern
Dimensions
mm
(inches)
www.ixysic.com
7
INTEGRATED CIRCUITS DIVISION
LBA127
MECHANICAL DIMENSIONS
LBA127STR Tape & Reel
330.2 DIA.
(13.00 DIA.)
Top Cover
Tape Thickness
0.102 MAX.
(0.004 MAX.)
W=16.00
(0.63)
Bo=10.30
(0.406)
K0 =4.90
(0.193)
Ao=10.30
(0.406)
P=12.00
(0.472)
K1 =4.20
(0.165)
Embossed Carrier
Embossment
User Direction of Feed
Dimensions
mm
(inches)
NOTES:
1. Dimensions carry tolerances of EIA Standard 481-2
2. Tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2
LBA127PTR Tape & Reel
2.00
(0.079)
330.2 DIA.
(13.00 DIA.)
Top Cover
Tape Thickness
0.102 MAX.
(0.004 MAX.)
Embossment
W = 16.00
(0.63)
7.50
(0.295)
Bo = 10.30
(0.406)
K0 = 2.70
(0.106)
K1 = 2.00
(0.079)
Embossed Carrier
4.00
(0.157)
P = 12.00
(0.472)
User Direction of Feed
Ao = 10.30
(0.406)
Dimensions
mm
(inches)
NOTES:
1. All dimensions carry tolerances of EIA Standard 481-2
2. The tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2
For additional information please visit our website at: www.ixysic.com
IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make
changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated
Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to
its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other
applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe
property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice.
8
Specification: DS-LBA127-R12
©Copyright 2012, IXYS Integrated Circuits Division
OptoMOS® is a registered trademark of IXYS Integrated Circuits Division
All rights reserved. Printed in USA.
12/22/2012
Similar pages