MPD A231R Compact, regulated, 2w single & dual output dc/dc converter Datasheet

A200R Series
Compact, Regulated, 2W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
Parameter
● 2W Output Power
Input Voltage Range
● Compact DIP Case
● 500 VDC Isolation
● Tight Line/Load Regulation Input Filter
Reverse Polarity Input Current
● Single & Dual Outputs
Short Circuit Input Power
● 20 Standard Models
Output
● 1.0 MH MTBF
Parameter
● Industry Standard Pin-Out Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
5 VDC Input
4.5
12 VDC Input 10.8
24 VDC Input 21.6
48 VDC Input 43.2
π (Pi) Filter
Conditions
Min.
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 10% to 100%
Typ.
5.0
12.0
24.0
48.0
Typ.
±2.0
±1.0
±0.2
±0.2
40
Over Line, Load & Temp.
Max.
5.5
13.2
26.4
52.8
Units
0.5
2,000
A
mW
Max.
±4.0
±3.0
±0.3
±0.5
50
75
5
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
μSec
%
%/ºC
120
VDC
±0.01
50
±6.0
±0.02
Typ.
Max.
100
80
150
Min.
Typ.
-25
-25
-40
Free Air Convection
RH, Non-condensing
Max.
+71
+90
+125
Units
ºC
ºC
ºC
95
%
50% Load Step Change
Continuous
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
500
1,000
40
Units
VDC
MΩ
pF
kHz
Environmental
Parameter
Operating Temperature Range
MicroPower Direct
232 Tosca Drive
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Storage Temperature Range
Cooling
Humidity
Conditions
Physical
Case Size
Case Material
Weight
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.42 Oz (12g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
Typ.
800
Max.
Units
kHours
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
7.5
15.0
30.0
55.0
260
3,000
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec.
All Models
VDC
ºC
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
Voltage (VDC)
Nominal
Range
5
5
5
5
5
12
12
12
12
12
24
24
24
24
24
48
48
48
48
48
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
43.2 - 52.8
43.2 - 52.8
43.2 - 52.8
43.2 - 52.8
43.2 - 52.8
Input
Current (mA)
Output
Fuse Rating
Reflected
Efficiency
Slow-Blow
Current
Ripple Voltage Current
(%, Typ)
(mA)
(VDC) (mA, Max) (mA, Min)
Full-Load No-Load Current
(mA, Typ)
A201R
A202R
A203R
A204R
A205R
A211R
A212R
A213R
A214R
A215R
A221R
A222R
A223R
A224R
A225R
A231R
A232R
A233R
A234R
A235R
Notes:
800
730
690
740
740
330
295
265
280
280
163
135
135
135
135
83
70
70
80
80
80
80
80
80
80
40
40
40
40
40
20
20
20
20
20
10
10
10
10
10
80
80
80
80
80
30
30
30
30
30
15
15
15
15
15
10
10
10
10
10
5.0
12.0
15.0
±12.0
±15.0
5.0
12.0
15.0
±12.0
±15.0
5.0
12.0
15.0
±12.0
±15.0
5.0
12.0
15.0
±12.0
±15.0
1. When measuring output ripple, it is recommended that an external 0.33 μF ceramic
capacitor be placed from the +Vout pin to the -Vout pin for single output units and from
each output to common for dual output units. For noise sensitive applications, the use
of 1.5 μF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a load step change of
50% to 100%.
3. Operation at no-load will not damage these units. However, they may not meet all
specifications.
4. Dual output units may be connected to provide a 24 VDC or 30 VDC output. To do this,
connect the load across the positive (+Vout) and negative (-Vout) outputs and float the
output common.
5. The converter should be connected to a low ac-impedance source. An input source with
a highly inductive impedance may affect the stability of the converter. In applications
where the converter output loading is high and input power is supplied over long lines,
it may be necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz) capacitor be
mounted close to the converter. For 5V input units a 2.2 μF is recommended, for 12V
input units, a 1.0 μF; and for 24V & 48V units a 0.47 μF.
6. It is recommended that a fuse be used on the input of a power supply for protection.
See the table above for the correct rating.
400
165
133
±83
±66
400
165
133
±83
±66
400
165
133
±83
±66
400
165
133
±83
±66
0.0
0.0
0.0
±0.0
±0.0
0.0
0.0
0.0
±0.0
±0.0
0.0
0.0
0.0
±0.0
±0.0
0.0
0.0
0.0
±0.0
±0.0
50
54
57
53
51
50
56
62
59
59
51
61
61
61
61
50
59
59
51
51
1,500
1,500
1,500
1,500
1,500
700
700
700
700
700
350
350
350
350
350
135
135
135
135
135
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
1, 24
+Vin
+Vin
2, 23
NC
-Vout
3, 22
NC
Common
10, 15
-Vout
Common
11, 14
+Vout
+Vout
12, 13
-Vin
-Vin
NC: No Connection
Capacitive Load
Single Output
Dual Output
470 μF Max
±220 μF Max
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Leads are tin plated for improved solderability.
MicroPower Direct
www.micropowerdirect.com
232 Tosca Drive Stoughton, MA 02072
■
TEL: (781) 344-8226
■
FAX: (781) 344-8481
■
E-Mail: [email protected]
Similar pages