OPEN FRAME & ENCLOSED ACE Series 3 0 0 - 9 0 0 W AT T S - A C / D C M O D U L A R O U T P U T FEATURES • • • • Flexible modular system architecture provides various output configurations. Harmonic attenuator (Complies with IEC61000-3-2). Universal input (85-264Vac). Remote on/off controls, alarm. ENVIRONMENTAL INPUT Voltage 85-264VAC or 120-350VDC. Frequency 47-63Hz. Leakage current 0.5mA (ACIN100V), 0.95mA (ACIN230V) Inrush current Cold start, 15A/30A @ 115VAC Cold start, 30A/30A @ 230VAC. Isolation In/Out 3kVac. In/Gnd 2kVac. Out/Gnd 500Vac. OUTPUT Output voltage See table. Voltage adjustment See table. Output current See table. Output power (110/230Vin) See table for individual modules. ACE300F: 250W/300W ACE450F: 400W/450W ACE650F: 600W/650W ACE900F: 800W (1KW peak) / 900W (1KW peak). Number of slots 76 ACE300F: 4 ACE450F: 5 ACE650F: 5 ACE900F: 6 Ripple & noise See table. Line regulation See table. Load regulation See table. Over voltage protection 115% - 140% of rated voltage. Over current protection Over 105% min. of rated current. Startup time 500ms max. Holdup time 20ms typical. Efficiency 78%-80% typical. Operating temperature -20°C to 70°C (Refer to derating curve) Consult Powerbox office. Humidity 20 – 75% RH Non-Condensing Vibration 19.6m/s2 (2G) 10Hz-55Hz 3 minutes x, y and z axes 60 minutes Impact 196.1m/s2 (20G), 11ms once along x, y and z axes STANDARDS Safety standards EN60950-1, EN50178, UL60950-1 and C-UL IEC60950 and DEN-AN (AC input only) CE Marking Complies with LVD and EMC Directives C Tick AS/NZS CISPR11 Group 1, Class A Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B Complies with EN61000-4-2,EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8 and EN61000-4-11 EMI standards EMC standards Input Harmonics Complies with IEC61000-3-2. MECHANICAL Dimensions Weight ACE300F: 103x63.5x254mm (WxHxD). ACE450F: 127x63.5x254mm (WxHxD). ACE650F: 127x63.5x279mm (WxHxD). ACE900F: 177.5x63.5x256mm (WxHxD). ACE300F: 1.7kg max. ACE450F: 2.2kg max. ACE650F: 2.4kg max. ACE900F: 3.0kg max. Doc. No. PBC9 Rev.D 10-8-12 ACE Series 150W SUITABLE SINGLE OUTPUT ITEM CODE A B C D E F G 50W SUITABLE SINGLE OUTPUT H J K L M N P R Number of slots used 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Voltage 2 3.3 5 7.5 12 15 18 24 34 48 3.3 5 12 15 24 Minimum current 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Current1(A) 26 26 26 18 13 10 8.5 6.5 4.5 3.2 10 10 5 4 2.5 Current2(A) — — — — — — — — — — — — — — — Peak current(A)*1 — — — — 14 12 10 8 5.5 4 — — — — — Line regulation(mV)max 20 20 20 36 48 60 72 96 120 192 20 20 48 60 96 Load regulation1(mV)max*5 40 40 40 100 100 120 120 150 180 300 40 40 100 120 150 Load regulation2(mV)max*6 — — — — — — — — — — — — — — — 0 to +50°C*2 80 80 80 120 120 120 120 120 120 150 80 80 120 120 120 Ripple (mVp-p)max -20 to 0°C*2 140 140 140 160 160 160 160 160 160 300 140 140 160 160 160 0 to +50°C*2 120 120 120 150 150 150 150 150 150 350 120 120 150 150 150 Ripple Noise (mVp-p)max -20 to 0°C*2 160 160 160 180 180 180 180 180 180 400 160 160 180 180 180 Temp Coeff. (mV)max 0 to +50°C 50 50 50 90 120 150 180 240 300 480 50 50 120 150 240 Drift (mV)max*6 20 20 20 36 48 60 72 96 120 192 20 20 48 60 96 2.00- 3.25- 4.99- 7.20- 11.5- 14.4- 17.3- 23.0- 33.0- 46.0- 3.25- 4.99- 11.5- 14.4- 23.0Output voltage setting(V) 2.20 3.45 5.30 7.80 12.5 15.6 18.7 25.0 35.0 50.0 3.45 5.30 12.5 15.6 25.0 Output voltage adjustment 1.60- 2.60- 4.00- 6.00- 9.00- 13.2- 16.5- 19.2- 27.2- 38.4- 2.60- 4.00- 9.00- 13.2- 19.2range(V)*4 2.60 3.60 5.50 8.20 13.2 16.5 19.2 26.4 37.4 52.8 3.60 5.50 13.2 16.5 26.4 Overcurrent protection(A) Works over 105% min of rated current or 101% min of peak current. Automatic recovery 3.00- 4.004.00- Works at 115%-140% of Overvoltage protection(V) Works at 115%-140% of rated voltage 4.80 5.25 5.25 rated voltage Function Remote sensing, remote ON/OFF, alarm(LV) Remote ON/OFF, alarm(LV) 300W SUITABLE SINGLE OUTPUT ITEM CODE 2A 2B 75W DUAL OUTPUT Y*7 W*7 Z*7 9*7 1 ±5 0 3 7 5 20 250 500 80 140 120 160 50 20 4.995.30 4.996.00 1 ±12 0 3.2 4.2 4 48 600 750 120 160 150 180 120 48 11.512.5 9.6013.2 1 ±15 0 2.5 3.5 — 60 600 750 120 160 150 180 150 60 14.515.6 13.216.5 1 ±24 0 1.6 2.5 — 60 600 750 120 160 150 180 150 60 23.025.0 19.226.4 6.90- 13.8- 17.2- 27.68.40 16.8 21.0 33.6 100W SUITABLE DUAL OUTPUT 150W DUAL OUTPUT * 2D 2E 2F 2G 2H 2J 2K S T U W Z I Number of slots used 2 2 2 Voltage 2 3.3 5 Minimum current 0 0 0 Current1(A) 60 60 60 Current2(A) — — — Peak current(A)*1 — — — Line regulation(mV)max 20 20 20 Load regulation1(mV)max*5 40 40 40 Load regulation2(mV)max*6 — — — 0 to +50°C*2 80 80 80 Ripple (mVp-p)max -20 to 0°C*2 140 140 140 0 to +50°C*2 120 120 120 Ripple Noise (mVp-p)max -20 to 0°C*2 160 160 160 Temp Coeff. (mV)max 0 to +50°C 50 50 50 Drift (mV)max*6 20 20 20 2 7.5 0 40 — — 36 100 — 120 160 150 180 90 36 2 12 0 25 — 34 48 100 — 120 160 150 180 120 48 2 15 0 20 — 27 60 120 — 120 160 150 180 150 60 2 18 0 17 — 23 72 120 — 120 160 150 180 180 72 2 24 0 14 — 20 96 150 — 120 160 150 180 240 96 2 34 0 10 — 14 120 180 — 120 160 150 180 300 120 2 48 0 7 — 10 192 300 — 150 300 350 400 480 192 1 V1; 5 V1; 5 0 0 10 5 — — — — 20 20 40 40 — — 80 80 140 140 120 120 160 160 50 50 20 20 1 V1; 5 V1; 12 0 0 10 4.2 — — — — 20 48 40 100 — — 80 120 140 160 120 150 160 180 50 120 20 48 1 V1; 5 V1; 24 0 0 10 2.1 — — — — 20 96 40 150 — — 80 120 140 160 120 150 160 160 50 240 20 96 1 ±12 0 6.4 8 10 48 600 750 140 200 230 350 120 48 1 ±15 0 5.5 7 8 60 600 750 140 200 230 350 150 60 1 7.207.80 6.008.20 11.512.5 9.0013.2 14.415.6 13.216.5 17.318.7 16.519.2 23.025.0 19.226.4 33.035.0 27.237.4 46.050.0 38.452.8 4.99- 4.99- 4.99- 11.5- 4.99- 23.0- 11.514.4-15.6 5.30 5.30 5.30 12.5 5.30 25.0 12.5 4.99- 3.00- 4.99- 7.50- 4.99- 15.0- 9.6013.2-16.5 5.50 5.50 5.50 13.2 5.50 26.4 13.2 Output voltage setting(V) Output voltage adjustment range(V)*4 Overcurrent protection(A) Overvoltage protection(V) Function 2.002.20 1.602.60 3.253.45 2.603.60 4.995.30 4.005.50 Input module 2C OPEN FRAME & ENCLOSED 3 0 0 - 9 0 0 W AT T S - A C / D C M O D U L A R O U T P U T Works over 105% min of rated current or 101% min of peak current. Automatic recovery 3.00- 4.004.80 5.25 Works at 115%-140% of rated voltage Remote sensing, remote ON/OFF, alarm(LV) *1 Operating condition of peak current : Peak current is less than 10sec., duty is less than 35% and average current is less than Remote ON/OFF Same as W, Z — *8 Ratings of V2 can draw up to 50% of rated current at the time of 0A in load of V1.(Only module S,T,U. refer to instruction manual 4.2 for details.) rated current. (rated current2 at Module W, Z, 9, Q and V) *2 Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN : RM101). Ripple and Ripple Noise is measured by using measuring board with capacitor of 22mF within 150mm from output terminal. *3 Drift is changed in DC output for an eight hour period after half-hour warm-up at 25C, with the input voltage held constant at * Each output of module Y-Z, 9, Q and V is a ground common type (not isolated),each output ofmodule S,T and U is isolated. = For ACE300F,450F and 650F , input and output terminals can be set at the same side if Input module (code:I) is installed instead of the most left module. * Modules which can correspond to medical electrical equipment (UL2601-1, EN60601-1) are all modules except module S, T the rated input/output. *4 When the output voltage of module A is used less than 2.0V, keep minimum output current 2.6A. and U. Refer to instruction manual 7. for details. *5 It is a value from 0 to rated output current1. The current on non-measurement side is fixed. *6 It is a value from 0 to rated output current2. The current on non-measurement side is fixed. *7 The sum of +power and -power must be less than output power(Y:50W, W:76.8W, Z:75W, 9:76.8W, Q:153.6W, V:165W). Doc. No. PBC9 Rev.D 10-8-12 Powering Progress – www.powerbox.com.au 77 OPEN FRAME & ENCLOSED ACE Series 3 0 0 - 9 0 0 W AT T S - A C / D C M O D U L A R O U T P U T TECHNICAL ILLUSTRATIONS OUTPUTSIDE VIEW OUTPUT MODULE SIDE VIEW AND CONNECTOR PIN ASSIGN 78 Doc. No. PBC9 Rev.D 10-8-12 ACE Series TECHNICAL ILLUSTRATIONS ACE300F OPEN FRAME & ENCLOSED 3 0 0 - 9 0 0 W AT T S - A C / D C M O D U L A R O U T P U T ACE450F Doc. No. PBC9 Rev.D 10-8-12 Powering Progress – www.powerbox.com.au 79 OPEN FRAME & ENCLOSED ACE Series 3 0 0 - 9 0 0 W AT T S M O D U L A R O U T P U T A C / D C G E N E R A L ACE650F ACE900F 80 Doc. No. PBC9 Rev.D 10-8-12