Skyworks AS196-307LF Gaas ic high-isolation spdt nonreflective switch with driver lf-6 ghz Datasheet

DATA SHEET
AS196-307, AS196-307LF: GaAs IC High-Isolation SPDT
Nonreflective Switch with Driver LF–6 GHz
Features
Functional Block Diagram
Positive voltage control (0/3 to 0/5 V)
● High isolation (55 dB @ 0.9 GHz and 1.9 GHz)
● LPCC 4 x 4 mm package
● Integrated silicon CMOS driver
● Nonreflective
● Available lead (Pb)-free and RoHS-compliant MSL-1 @ 260 °C
per JEDEC J-STD-020
●
J2
CBL
50
CBL
J1
50
Description
The AS196-307 is a GaAs FET IC SPDT nonreflective switch
packaged in a 16-lead exposed pad plastic package for low-cost,
high-isolation commercial applications. Ideal building block for
base station applications where synthesizer isolation is critical.
Typical applications include GSM, PCS, WCDMA, 2.4 and
5.8 GHz ISM and wireless local loop.
NEW
J3
CBL
Decoder
VDD
VCTL
CBL = 47 pF for operation > 500 MHz.
Skyworks offers lead (Pb)-free, RoHS (Restriction of
Hazardous Substances)-compliant packaging.
Electrical Specifications (0, 5 V) -40 °C to +85 °C
Parameter(1)
Frequency
Min.
Typ.
Max.
Unit
0.9
1.0
1.2
1.6
1.15
1.25
1.40
2.00
dB
dB
dB
dB
Insertion loss
LF–2 GHz
LF–3 GHz
LF–4 GHz
LF–6 GHz
Isolation(2)
LF–2 GHz
LF–3 GHz
LF–4 GHz
LF–6 GHz
VSWR (on state)
LF–2 GHz
LF–6 GHz
1.3:1
1.3:1
1.5:1
1.6:1
VSWR (off state)
0.5–6 GHz
1.35:1
1.7:1
50
43
35
25
55
50
40
30
dB
dB
dB
dB
1. All measurements made in a 50 Ω system, unless otherwise specified.
2. Backside of exposed pad must be connected to RF ground to obtain specified isolation.
BUY
NOW
Innovation to GoTM
Now available for purchase online.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200126 Rev. D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • August 15, 2006
1
DATA SHEET • AS196-307, AS196-307LF
Operating Characteristics (0, 5 V) -40 °C to +85 °C
Parameter
Condition
Switching characteristics(1)
Rise, fall
On, off
Video feedthru
Frequency
Min.
Typ.
10/90% or 90/10% RF
50% CTL to 90/10% Rf
TRISE = 3 ns, BW = 500 MHz
Max.
Unit
30
50
25
ns
ns
mV
Input power for 1 dB compression
VCTL = 0/3 V
VCTL = 0/5 V
0.9–6 GHz
0.9–6 GHz
17
24
21
27
dBm
dBm
Intermodulation intercept point (IP3)
For two-tone input power +8 dBm
VCTL = 0/3 V
VCTL = 0/5 V
0.9–6 GHz
0.9–6 GHz
30
38
38
46
dBm
dBm
Thermal resistance
25
Control voltage
Low (“0”)
High (“1”)
Control current
VCTL = “0” or “1”. VDD = 2.6 to 5 V
Supply voltage
VDD
Supply current
VDD = 3 V
VDD = 5 V
°C/W
0
VDD–0.6
0.5
VDD
V
V
5
2.6
µA
3
5
V
10
20
50
100
µA
µA
1. VDD must be powered on by a minimum of 10 ns prior to VCTL.
Typical Performance Data (0, 5 V)
0
0
-0.25
-10
-0.75
Isolation (dB)
Insertion Loss (dB)
-0.50
J1–J3
-1.00
-1.25
J1–J2
-1.50
-1.75
-20
-30
J1–J2
-40
J1–J3
-50
-2.00
-60
-2.25
-70
-2.50
0
1
2
3
4
5
6
0
1
2
3
4
Frequency (GHz)
Frequency (GHz)
Insertion Loss, 25 °C
VDD = 5 V, VCTL = 0/5 V
Isolation, 25 °C
VDD = 5 V, VCTL = 0/5 V
5
2.0
Output Off
VSWR
1.8
1.6
1.4
1.2
Input On
Output On
1.0
0
1
2
3
4
5
6
Frequency (GHz)
VSWR, 25 °C
VDD = 5 V, VCTL = 0/5 V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
August 15, 2006 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200126 Rev. D
6
DATA SHEET • AS196-307, AS196-307LF
0
0
-0.25
-10
-0.75
Isolation (dB)
Insertion Loss (dB)
-0.50
J1–J3
-1.00
-1.25
J1–J2
-1.50
-1.75
-20
-30
J1–J2
-40
J1–J3
-50
-2.00
-60
-2.25
-70
-2.50
0
1
2
3
4
5
0
6
1
2
3
4
5
Frequency (GHz)
Frequency (GHz)
Insertion Loss, 85 °C
VDD = 5 V, VCTL = 0/5 V
Isolation, 85 °C
VDD = 5 V, VCTL = 0/5 V
2.0
6
0
-0.25
1.8
Insertion Loss (dB)
-0.50
VSWR
Output Off
1.6
Input On
1.4
1.2
-0.75
J1–J3
-1.00
-1.25
J1–J2
-1.50
-1.75
-2.00
Output On
-2.25
1.0
0
1
2
3
4
5
-2.50
6
0
2
3
4
Frequency (GHz)
VSWR, 85 °C
VDD = 5 V, VCTL = 0/5 V
Insertion Loss, -40 °C
VDD = 5 V, V = 0/5 V
0
5
6
2.0
-10
Output Off
1.8
-20
-30
VSWR
Isolation (dB)
1
Frequency (GHz)
J1–J2
-40
1.6
1.4
J1–J3
-50
Input On
1.2
-60
Output On
-70
1.0
0
1
2
3
4
5
6
0
1
2
3
4
Frequency (GHz)
Frequency (GHz)
Isolation, -40 °C
VDD = 5 V, VCTL = 0/5 V
VSWR, -40 °C
VDD = 5 V, VCTL = 0/5 V
5
6
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200126 Rev. D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • August 15, 2006
3
DATA SHEET • AS196-307, AS196-307LF
Compression Point vs.
Voltage and Temperature
IP3 vs. Voltage and Temperature
Control Voltage
(V)
Temperature
(°C)
Input Power
@ 1 dB
Compression
(dBm)
3
-40
20.5
Input Power
@ 0.1 dB
Compression
(dBm)
16.5
3
25
20
15.3
3
85
19
14
5
-40
28.5
23
5
25
28
23
5
85
27.5
23
Frequency: 500 MHz.
Control Voltage
(V)
Temperature
(°C)
IP3 @ 5 dBm
Each T one (dBm)
3
-40
45.5
3
25
45
3
85
34
5
-40
45.5
5
25
45.5
5
85
40.5
Two tone input power: 5 dBm each tone.
Tone frequencies: 900 and 901 MHz.
Truth Table
J1–J2
0
Insertion loss
Isolation
1
Isolation
Insertion loss
Value
-65 °C to +150 °C
Pin Out (Top View)
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION: Although this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce potentials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
GND
-40 °C to +85 °C
Storage temperature
16
15
14
13
12 J2
VCC 1
Connect back
side exposed
paddle to ground
VCTL 2
J1 3
11 GND
10 GND
GND 4
9
5
6
7
8
GND
Operating temperature
GND
-0.2 V, +8 V
N/C
Control voltage
“0” = 0–0.5 V.
“1” = 3.5–5 V.
VDD = 5 V.
N/C
1 W max. > 500 MHz,
0/8 V control
N/C
RF input power
J1–J3
GND
Characteristic
VCTL
GND
Absolute Maximum Ratings
Recommended Solder Reflow Profiles
Refer to the “Recommended Solder Reflow Profile”
Application Note.
Tape and Reel Information
Refer to the “Discrete Devices and IC Switch/Attenuators
Tape and Reel Package Orientation” Application Note.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
August 15, 2006 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200126 Rev. D
DATA SHEET • AS196-307, AS196-307LF
Evaluation PCB
LPCC 4 x 4 (-307)
Top View
PCB Evaluation
Board SP4T
LPCC-16
(4 X 4 mm)
VP
J2
VCTL
1
J3
47 pF
Capacitor
5 Places
Pin 1
Indicator
Bottom View
0.013 (0.325 mm)
Ref.
0.10
-A-
0.026
(0.65 mm)
BSC
0.110
(2.79 mm)
± 0.002
(0.05 mm)
PC Mount
SMA Connector
5 Places
J1
Pin 1
-B-
0.157 (4.00 mm)
± 0.008 (0.20 mm)
Sq.
0.076 (1.95 mm)
BSC
0.076 (1.95 mm)
BSC
0.016
(0.40 mm)
Ref.
0.110 (2.79 mm)
± 0.002 (0.05 mm)
AS196-307
SK39110
REV 2
0.033 (0.85 mm)
± 0.004 (0.10 mm)
0.015 (0.387 mm) Ref.
Thru Path
PCB# SK39110. Material: FR4.
The circuit board used in the final application should employ RF circuit design techniques. RF
signal lines should have 50 Ω impedance. The package bottom ground plane should be
connected directly to PCB ground plane. A sufficient number of via holes should be used to
connect the top and bottom ground planes. The evaluation circuit board shown is available
upon request.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200126 Rev. D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • August 15, 2006
5
DATA SHEET • AS196-307, AS196-307LF
Copyright © 2002, 2003, 2004, 2005, 2006, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided
by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and
Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, “Breakthrough Simplicity” and “Innovation to Go” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Thirdparty brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at
www.skyworksinc.com, are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
August 15, 2006 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200126 Rev. D
Similar pages