MORNSUN B0309XT-2W 2w, fixed input voltage , isolated unregulated single output Datasheet

DC/DC Converter
B_(X)T-2W series
2W, Fixed input voltage , isolated & unregulated single
output
FEATURES
l Miniature SMD package
l Isolation voltage: 1K VDC
l Operating temperature range: -40℃~+85℃
l Good temperature characteristic
l Internal surface mounted design
l No External Component Required
l International standard pin-out
Patent Protection RoHS
B_(X)T-2W series is specially designed for applications where an isolated voltage is required in a distributed power supply system. It is suitable
for:
1.Where the voltage of the input power supply is stable (voltage variation: ±10%Vin);
2.Where isolation is necessary between input and output (isolation voltage ≤ 1000VDC);
3.Where do not has high requirement of line regulation , load regulation and the ripple & noise of the output voltage;
Such as: pure digital circuits, low frequency analog circuits, and IGBT power device driving circuits.
Selection Guide
Input Voltage (VDC)
Part No.
B0303XT-2W
B0309XT-2W
Output
Max. Capacitive
Load
@ Full Load
(µF)
Output Voltage
(Range)
(VDC)
Output Current
(mA)(Max./Min.)
3.3
(2.97-3.63)
3.3
400/40
70/74
9
222/23
79/83
3.3
400/40
67/71
B0503T-2W
B0505(X)T-2W
Efficiency
(%,Min./Typ.)
Nominal
5
400/40
76/80
9
222/23
75/79
12
167/17
75/79
B0515(X)T-2W
15
133/14
76/80
B1205(X)T-2W
5
400/40
74/78
12
167/17
76/80
15
133/14
77/81
24
84/8
83/87
15
133/14
81/85
B2405(X)T-2W
5
400/40
74/78
B2412(X)T-2W
12
167/17
76/80
15
133/14
77/81
24
84/9
76/80
B0509T-2W
B0512T-2W
B1212(X)T-2W
B1215(X)T-2W
5
(4.5-5.5)
12
(10.8-13.2)
B1224T-2W
B1515T-2W
B2415T-2W
15
(13.5-16.5)
24
(21.6-26.4)
B2424T-2W
220
Input Specifications
Item
Input Current (full load / no-load)
Surge Voltage (1sec. max.)
Operating Conditions
Min.
Typ.
Max.
3.3V input
--
730/60
--
5V input
--
507/55
--
12V input
--
214/30
--
15V input
--
157/20
--
24V input
--
107/15
--
3.3V input
-0.7
--
5
5V input
-0.7
--
9
12V input
-0.7
--
18
2014.05.22-B/1
Unit
mA
VDC
Page 1 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
B_(X)T-2W series
Surge Voltage (1sec. max.)
15V input
-0.7
--
21
24V input
-0.7
--
30
Input Filter
VDC
Capacitor filter
Output Specifications
Item
Operating Conditions
Min.
Output Voltage Accuracy
Typ.
Max.
Unit
See tolerance envelope graph (Fig. 1)
Line Regulation
Input voltage change: ±1%
Load Regulation
10%-100% load
--
--
±1.2
3.3VDC output
--
12
20
5VDC output
--
12.8
15
9VDC output
--
8.3
15
12VDC output
--
6.8
15
15VDC output
--
6.3
15
24VDC output
--
6.3
15
--
%
Ripple & Noise*
20MHz bandwidth
--
100
200
mVp-p
Temperature Drift Coefficient
100% load
--
--
±0.03
%/℃
--
--
1
s
Output Short Circuit Protection**
Note: 1. * Ripple and noise tested with “parallel cable” method, please see DC-DC Converter Application Notes for specific operation methods.
2. **Supply voltage must be discontinued at the end of short circuit duration.
General Specifications
Item
Operating Conditions
Min.
Isolation Voltage
Input-output, with the test time of 1 minute and the leak
current lower than 1mA
1000
Isolation Resistance
Input-output, isolation voltage 500VDC
Typ.
Max.
--
--
VDC
MΩ
1000
--
--
B2424(X)T-2W
--
100
--
Other models
--
30
--
-40
--
85
-55
--
125
--
25
--
--
--
300
Isolation Capacitance
Input-output, 100KHz/0.1V
Operating Temperature
Derating if the temperature ≥85℃ (see Fig. 2)
Storage Temperature
Casing Temperature Rise
Ta=25℃
Pin Welding Resistance Temperature
Welding spot is 1.5mm away from the casing, 10 seconds
Unit
pF
℃
Peak temp.≤245℃, maximum duration
time≤60s at 217℃.
For actual application, please refer to
IPC/JEDEC J-STD-020D.1.
--95
%
Reflow Soldering Temperature
Storage Humidity
Non-condensing
Switching Frequency
100% load, nominal input voltage
MTBF
MIL-HDFK-217F@25℃
--
500
3500
--
---
KHz
K hours
Physical Specifications
Casing Material
Black flame-retardant heat-proof epoxy resin (UL94-V0)
Package Dimensions
12.70*11.20*6.25 mm
Weight
1.4g(Typ.)
Cooling Method
Free air convection
EMC Specifications
EMI
Conducted disturbance
CISPR22/EN55022
CLASS A (see Fig. 5 for recommended circuit)
EMS
Electrostatic discharge
IEC/EN61000-4-2
Contact
±6KV
perf. Criteria B
2014.05.22-B/1
Page 2 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
B_(X)T-2W series
Product Characteristic Curve
Output Pow er Per centage(%)
Tolerance Envelope Graph
+10%
Ty p ic
+5%
Rated
Output Vo ltage
al Lo a
d Cu rv
+2.5%
e
O utput Vo ltage
Ac curac y(%)
-2.5%
-7.5%
50
70
100
Tem pe ratu re De rating Graph
120
100
80
60
Safe Operating Area
40
20
0
-40
Output Curre nt Percentage(%)
0
40
85 105 120
Ambi ent Temperature(℃ )
( Nominal Input Voltage)
Fig. 2
Fig. 1
100
Efficiency Vs Input Voltage (Full Load)
Efficiency Vs Output Load(Vin=5V)
100
95
90
B0505(X)T-2W
80
85
B0505(X)T-2W
80
75
70
65
60
Efficiency(%)
Efficiency(%)
90
70
60
50
40
30
20
55
10
0
5.5
5.4
5.3
5.2
5.1
5.0
4.9
4.8
4.7
4.6
50
10
20
Efficiency Vs Input Voltage (Full Load)
40
50
60
70
80
90
100
Efficiency Vs Output Load(Vin=24V)
100
100
95
90
90
B2405(X)T-2W
80
85
B2405(X)T-2W
80
75
70
65
60
Efficiency(%)
Efficiency(%)
30
Output Current Percentage(%)
Input Voltage (V)
70
60
50
40
30
0
26.5
26.0
25.5
25.0
24.5
24.0
23.5
23.0
10
22.5
20
50
22.0
55
10
20
30
40
50
60
70
80
90
100
Output Current Percentage(%)
Input Voltage (V)
Design Reference
1. Typical application
If it is required to further reduce input and output ripple, a filter capacitor can be connected to the input and output terminals, see Fig.3.
Moreover, choosing suitable filter capacitor is very important, start-up problems may be caused by too large capacitance. To ensured the
modules running well, the recommended capacitive load values as shown in Table 1.
The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat
protection that is connected to the input or output end in series (see Fig. 4).
+Vo
Vin
Cin
DC
DC
Vin
Cout
+Vo
DC DC
GND
GND
REG
REG
0V
0V
Fig.4
Fig.3
Recommended capacitive load value table (Table 1)
Vin(VDC)
Cin(µF)
Vo (VDC)
Cout(µF)
3.3
4.7
3.3
10
5
4.7
5
10
12
2.2
9
2.2
15
1
12
2.2
24
0.47
15
1
--
--
24
0.47
It is not recommended to connect any external capacitor when output power is less than 0.5W.
2014.05.22-B/1
Page 3 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
B_(X)T-2W series
2. EMC typical recommended circuit
Vin
Vin
C1
GND
DC/DC
GND
Input voltage (VDC)
+Vo
LOAD
C2
EMI
C1
3.3/5/12/15
24
2.2µF /50V
4.7µF /50V
C2
Refer to the Cout in Fig.3
0V
Fig. 5
3. Output load requirements
To ensure the module work efficiently and reliably, during the operation, the min. output load should be no less than 10% of the full load. If the
actual output power is low, please connect a resister to the output terminal in parallel, with a recommenced resistance which is 10% of the
rated power, and derating is required during operation.
4. For more information please find the application notes on www.mornsun-power.com
Dimensions and Recommended Layout
Notes:
1.
Packing Information please refer to 'Product Packing Information'. Packing bag number: 58200021;
2.
If the product is operated under the min. required load, the product performance cannot be guaranteed to comply with all
performance indexes in this datasheet;
3.
The max. capacitive load should be tested within the input voltage range and under full load conditions;
4.
Unless otherwise specified, data in this data sheet should be tested under the conditions of Ta=25°C, humidity<75% when inputting
nominal voltage and outputting rated load;
5.
All index testing methods in this datasheet are based on our Company’s corporate standards;
6.
The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products
will exceed the above-mentioned requirements, and please directly contact our technicians for specific information;
7.
We can provide product customization service;
8.
Specifications of this product are subject to changes without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2014.05.22-B/1
Page 4 of 4
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Similar pages