DB Lectro NT75-1CS16DC9V0.413.5 Low coil consumption. / switching capacity up to 16a. Datasheet

NT75-1 & NT75-2
E9930952E01
R2033977.02
on Pending
Patent No. 98324524X 98324532.1
28.5×12.5×15 (29×12.7×15.7)
Features
Small size, light weight.
Low coil consumption.
Switching capacity up to 16A.
PC board mounting.
Suitable for household electrical appliance, automation system,
telecommunication facilities and remote control facilities.
electrical equipment, instrument,
meter
Ordering Information
NT75-1
C S 12
1
2
3
DC12V 0.72 3.5
4
5
6
7
4 Contact rating:1A,1C:12A/250VAC 30VDC;
1A,1C(0.72W):16A/250VAC 30VDC;
2A,2C(0.41W):8A/250VAC 30VDC
5 Coil rated Voltage(V):DC:5,6,9,12,24,48
6 Coil power consumption:0.25:0.25W;0.41:0.41W;0.72:0.72W
7 Pole-distance:3.5:3.5mm;5.0:5.0mm
1 Part number:NT75-1、NT75-2
2 Contact arrangement:NT75-1:A:1A;C:1C
NT75-2:2A:2A;2C:2C
3 Enclosure:S: Sealed type;Z: Dust cover
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
1ASPSTNO
1CSPDT(B-M)2ADPSTNO
2CDPDT(B-M)
AgCdO
AgSnO2In2O3
Max. Switching Power
480W
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
life
Mechanical
60VDC 380VAC
አ50m
105
107
1A,1C;12A/250VAC,30VDC;
2A,2C:8A/250VAC,30VDC
4000VA
1A,1C(0.72W):16A/250VAC, 30VDC
2C:2150W
21250VA
Max. Switching Current:16A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
tem 3.31 of IEC255-7
Coil Parameter
Coil
voltage
VDC
Dash
numbers
Rated
005-250
006-250
009-250
012-250
024-250
048-250
060-250
005-410
006-410
009-410
012-410
024-410
048-410
060-410
110-410
005-720
006-720
009-720
012-720
024-720
048-720
5
6
9
12
24
48
60
5
6
9
12
24
48
60
110
5
6
9
12
24
48
Max.
6.5
7.8
11.7
15.6
31.2
62.4
78
6.5
7.8
11.7
15.6
31.2
62.4
78
143
6.5
7.8
11.7
15.6
31.2
62.4
Coil
resistance
±10%
100
144
324
576
2304
9216
12857
61
88
198
351
1405
5620
7500/15%
25200/15%
34.7
50
112.5
200
800
3200
Pickup
voltage
VDC(max)
(70%of rated
voltage )
release voltage
VDC(min)
(10% of rated
voltage)
3.5
4.2
6.3
8.4
16.8
33.6
42
3.5
4.2
6.3
8.4
16.8
33.6
42
77
3.5
4.2
6.3
8.4
16.8
33.6
0.5
0.6
0.9
1.2
2.4
4.8
6.0
0.5
0.6
0.9
1.2
2.4
4.8
6.0
11.0
0.5
0.6
0.9
1.2
2.4
4.8
Coil power
consumption
W
Operate
Time
ms
Release
Time
Ms
0.25
10
5
0.41
10
5
0.72
10
5
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
85
www.dblectro.com
NT75-1 & NT75-2
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
500M
min (at 500VDC)
Item 7 of IEC255-5
50Hz 1000V
50Hz 4000V
Item 6
Item 6
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
100m/s2
11ms
10~55Hz double amplitude
10N
2352 30.5s
-40~70
85% (at 40)
11g
12g(NT75-2)
1.5mm
of IEC255-5
of IEC255-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.
Safety approvals
Safety approval
Load
TüV
16A/250VAC 30VDC
Dimensions (Unit: mm)
L:3.5mm or 5.0mm
Mounting (Bottom views)
Dimensions
mm
>àçÇá
0.4
0.5
1.0
1.3
1.5
3.5
5.0
7.5
12.5
15
20
28.5
0.016
0.020
0.039
0.051
0.059
0.138
0.197
0.295
0.492
0.591
0.787
1.122
Wiring diagram
(Bottom views)
NOTES 1).Dimensions are in millimeter.
2).Inch equivalents are given for general information only.
Reference Data
www.dblectro.com
Similar pages