Astrodyne LFM100 100w ultraminiature open frame switching power supply Datasheet

LFM100
1 0 0 W U l t r a m i n i a ture Open Frame Switching Power Supplies
series
Universal 85-265VAC Input
High Efficiency
Regulated Outputs
3000V Isolation
Single Outputs
UL60950 & EN60950 Approved
3”W x 5”L x 1.24”H
3”W x 5”L x 1.34”H (5V Output)
Model Number
Output Voltage
0.156” SPACED CONNECTORS
LFM100-5
5 VDC
LFM100-9
9 VDC
LFM100-12
12 VDC
LFM100-15
15VDC
LFM100-18
18VDC
LFM100-24
24VDC
LFM100-48
48VDC
Output Amps(max)
20A
11.2A
8.4A
6.7A
5.6A
4.2A
2.1A
Order On-Line!
WWW.ASTRODYNE.COM
astrodyne.com
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181
LFM100
1 0 0 W U l t r a m i n i a ture Open Frame Switching Power Supplies
INPUT SPECIFICATIONS
MECHANICAL SPECIFICATIONS
0.22 [5.70]
85-265 VAC (See Note 2)
47-63 Hz
25A@100V, 50A@200V Input *
3.5mA max.
ACL
ACN
OUTPUT SPECIFICATIONS
5 Volt Output
V+
See Selection Chart
+/- 1%
+/- 0.5%
+/- 1%
+/-0.05%/°C
1% (See Note 1)
Continuous
Auto Recovery
20 mS, typ @ 115VAC
V-
0.06 [1.60]
1
2
3
4
5
6
7
8
0.22 [5.70]
0.08 [2.00]max
2.55 [64.80]
1.34 [34.00]max
3.00[76.20]
ACL
ACN
0.22 [5.70]
GENERAL SPECIFICATIONS
V+
3000VAC
85%, typ.
UL60950, EN60950
V-
Input-Out Isolation
Efficiency
Safety
1
2
3
4
5
6
7
8
0.06 [1.60]
5.00[127.00]
4.55 [115.60]
-
Voltage and Current
Load Regulation (10%-FL)
Line Regulation (LL-HL, FL)
Voltage Accuracy
Temperature Coefficient
Ripple/Noise
Short Circuit Protection
Over Voltage Protection
Hold Up Time
5.00[127.00]
4.55 [115.60]
-
Input Voltage Range
Frequency Range
Inrush Current, typ:
Leakage Current
series
0.22 [5.70]
0.08 [2.00]max
PHYSICAL SPECIFICATIONS
1.24 [32.00]max
Size
5VDC Output
3” x 5” x 1.34” +/-0.04” Tol.
All Others
3” x 5” x 1.24” +/-0.04” Tol.
Construction
Open Frame
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Cooling
Storage Temperature
0 to +40°C
Free Air Convection
-20 to +85°C *
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
2.55 [64.80]
3.00[76.20]
Pin #
Output Pin Functions
1, 2, 3, 4
5, 6, 7, 8
+ Output
- Output
Notes:
1) LFM5/9/12: Add a 0.1uF ceramic capacitor and a 220uF E.L.capacitor to
output for Ripple & Noise (R & N) measuring @ 20MHz BW.
All Others: Add a 0.1uF ceramic capacitor and a 10uF E.L.capacitor to
output for Ripple & Noise (R & N) measuring @ 20MHz BW.
2) Connections: AC Input - Molex 5277 or Equivalent
DC Output - Molex 5273 or Equivalent
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082
Fax: 508-823-8181