Sensortechnics CTU8002GD4 Oem pressure transmitters for industrial media Datasheet

CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
FEATURES
· 0...-1 to 0...100 bar,
0...-15 to 0...1500 psi
gage1 or absolute10
· For many industrial gases and liquids
· 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V or
4...20 mA output
· Field interchangeable
· For industrial use
MEDIA COMPATIBILITY
Wetted materials:
stainless steel 1.4404 (316L), ceramic AL2O3, NBR9
Housing:
stainless steel,protection class IP 64 (according to
DIN EN 60529) respectively NEMA 4X1
ELECTRICAL CONNECTION
SPECIFICATIONS11,12
Maximum ratings
0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V output
Supply voltage (reverse polarity protection)
12...30 V
CTx8...0
9...30 V
CTx8...1, ...6, ...7
9...30 V
CTx8...42
Maximum load current (source)
CTx8...0, ...1, ...6, ...7
Temperature limits
Storage
Operating8
Compensated
sensor
1 mA
-55 to 100°C
-40 to 100°C
0 to 70°C
Vibration (5 to 500 Hz)
Mechanical shock
3
December 2008 / 508
10 gRMS
50 g
2 x rated pressure
12 (9) to 30 V
1
Vout
2
-Vs
4
case
3
V
GND
4...20 mA output
+Vs
0 - 98 %RH
Humidity limits
Proof pressure
+Vs
sensor
1
N/C
2
-Vs
4
case
3
9 to 30 V
V
RL
GND
1/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
COMMON PERFORMANCE CHARACTERISTICS
Characteristics
Operating pressure
Min.
CTE8001...
CTE8N01...
CTE8P01...
CTE8002...
CTE8005...
CTE8010...
CTE8016...
CTE8020...
CTE8025...
CTE8035...
CTE8050...
CTE8070...
CTE8100...
CTU8015...
CTU8N15...
CTU8P15...
CTU8030...
CTU8100...
CTU8200...
CTU8300...
CTU8500...
CTU8700...
CTU81K0...
CTU81K5...
Typ.
0
-1
-1
0
0
0
0
0
0
0
0
0
0
0
-15
-15
0
0
0
0
0
0
0
0
1
+1
0
2
5
10
16
20
25
35
50
70
100
15
+15
0
30
100
200
300
500
700
1000
1500
Thermal effectss
(0 to 70°C)4
Offset
Span
0.02
0.02
Thermal effects
(-40 to 0°C, 70 to 100°C)
Offset
Span
0.03
0.03
Non-linearity, hysteresis (BSL) and repeatability5
±0.1
Long term stability6
±0.3
Output noise (0 < f < 1 kHz)
±0.04
Response time (10 to 90 %)
1
Power supply rejection
December 2008 / 508
Max.
Offset
CTx8...4
all others
0.05
0.002
Span
CTx8...4
all others
0.08
0.002
0.05
0.05
Unit
bar
p si
%FSO/°C
±0.3
%FSO
5
ms
%FSO/V
2/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
INDIVIDUAL PERFORMANCE CHARACTERISTICS
0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset
CT...8N...
Min.
Typ.
Max.
4.9
5
5.1
0.03
0.1
all others
7
Full scale span
CT...8N...
4.9
5
5.1
all others
9.9
10
10.1
Unit
V
25
Ω
3
5
mA
Min.
Typ.
Max.
Unit
CT...8N...
2.45
2.5
2.55
all others
0.45
0.5
0.55
CT...8N...
1.95
2
2.05
all others
3.95
4
4.05
Output impedance
Current consumption (no load)
0.5...4.5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset
Full scale span7
25
Ω
3
5
mA
Typ.
Max.
Unit
Output impedance
Current consumption (no load)
V
0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset
Min.
CT...8N...
2.45
all others
Full scale span7
2.5
2.55
0.03
0.08
CT...8N...
2.45
2.5
2.55
all others
4.95
5.0
5.05
25
Ω
3
5
mA
Unit
Output impedance
Current consumption (no load)
V
1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset
7
Full scale span
Min.
Typ.
Max.
CT...8N...
3.45
3.5
3.55
all others
0.95
1
1.05
CT...8N...
2.45
2.5
2.55
all others
4.95
5.0
5.05
25
Ω
3
5
mA
Unit
Output impedance
Current consumption (no load)
V
4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Zero pressure offset
7
Full scale span
Power consumption (IL = 20 mA)
December 2008 / 508
Min.
Typ.
Max.
CT...8N...
11.9
12.0
12.1
all others
3.9
4.0
4.1
CT...8N...
7.9
8.0
8.1
all others
15.9
16.0
16.1
250
mA
mW
3/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
Specification notes:
1. IP 64 protection is given when the connector is locked. For proper function the gage port is vented to the atmosphere through
the connector/cable assembly. Thus the cable end must have access to the ambient pressure.
2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C.
5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.
6. Long term stability is the change in output after one year or 1 million pressure cycles.
7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure.
8. Tests are in accordance with EN61000-6-2, April 1999.
9. Other material on special request. When using devices with optional nickel plated fittings, consider the media compatibility of
the fittings also.
10. Available for pressure ranges from 1 bar (15 psi) absolute upwards only.
11. CE-labelling is in accordance with 89/336/EEC.
12. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
OUTLINE DRAWING
NOM 72 (2.83)
52 (2.05)
vent hole¹
4
G 1/8"
(BSP)
1
3
M12 x 1
connector
21.8 (0.86)
diam.
6.5
(0.26)
Detail A
2
Detail A
4.0 (0.16)
diam.
Output
Pin
o-ring grove for
o-ring 11.8 x 1.8
(0.456 x 0.071)
(ZA004029)
mass: 72 g
December 2008 / 508
1
2
3
4
0...10 V
0.5...4.5 V
0...5 V, 1...6 V
+VS
Vout
case
-Vs
4...20 mA
+VS
NC
case
-Vs
dimensions in mm (inches)
4/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
RECOMMENDED ACCESSORY (not included in delivery)
ZK000101:
ZP000112-B:
Connector/cable assembly (different cable lenghts available)
Mating Connector (without cable)
NOM 2 m
PIN CONNECTION
(other cable lenghts on request)
36.5
NOM 60
Shield
Pin
Flying lead end
1
Brown
2
Green
3
White and shield
4
Yellow
Vent tube
Note:
For proper function of all gage
devices the vent tube must have
access to the ambient atmosphere.
M12x1
Ø 20
OPTIONAL PRESSURE FITTINGS
(brass, nickel plated)
B
Male
fittings
C
dimensions in mm
LOAD LIMITATION
4...20 mA output version
1400
Ohm
1200
A
D
1000
800
Female
fittings
op
e
ra ratin
ng g
e
600
G
F
400
200
E
H
0
B
8 (0.315)
12 (0.472)
11.5 (0.453)
16 (0.630)
12.5 (0.492)
8.5 (0.335)
12.5 (0.492)
10 (0.394)
14 (0.551)
December 2008 / 508
C
13 (0.512)
5.5 (0.217)
5 (0.197)
7 (0.276)
11 (0.433)
5 (0.197)
7 (0.276)
13 (0.512)
6 (0.236)
9
16 20
25 30 V
supply voltage
Dimensions in mm (inches)
Dimensions in mm (inches)
A
1/8" BSPT
1/4" BSPT
3/8" BSPT
1/2" BSPT
1/8" BSP
1/4" BSP
3/8" BSP
1/8" NPT
1/4" NPT
5
D (Hex.)
14 (9/16")
14 (9/18")
17 (11/16")
22 (7/8")
14 (9/16")
19 (3/4")
22 (7/8")
17 (11/16")
22 (7/8")
E
1/8" BSP
1/4" BSP
3/8" BSP
1/2" BSP
F
5 (0.197)
7 (0.276)
6 (0.236)
18 (0.707)
G
15 (0.591)
20 (0.787)
20 (0.787)
23 (0.906)
H (Hex.)
14 (9/16")
17 (11/16")
22 (7/8")
24 (15/16")
5/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
ELECTROMAGNETIC CAPABILITY8
Test conditions
Criterion Interference
Radiated, radio frequency
EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz
A
<1 %FSO
electromagnetic field immunity (RFI)
80 % AMC (1 kHz)
Electrical fast transient /
EN61000-4-4: Grade 3, ±2 kV
B
<1 %FSO
burst immunity (EFT)
Electrostatic discharge immunity
EN61000-4-2: Grade 4, ±8 kV, contact discharge
B
<1 %FSO
test (ESD)
Immunity to conducted disturbances EN61000-4-6: Grade 3, 0.15 to 80 MHz
A
<1 %FSO
induced by radio-frequency fields
10 V, 80 % AMC (1 kHz)
ORDERING INFORMATION
CTx8
E:
U:
xxx
bar calibration
psi calibration
CTE8000 series
001:
0 to 1 bar
N01: -1 to +1 bar
P01:
0 to -1 bar
002:
0 to 2 bar
005:
0 to 5 bar
010:
0 to 10 bar
016:
0 to 16 bar
020:
0 to 20 bar
025:
0 to 25 bar
035:
0 to 35 bar
050:
0 to 50 bar
070:
0 to 70 bar
100: 0 to 100 bar
CTU8000 series
015:
0 to 15
N15: -15 to +15
P15:
0 to -15
030:
0 to 30
100:
0 to 100
200:
0 to 200
300:
0 to 300
500:
0 to 500
700:
0 to 700
1K0: 0 to 1000
1K5: 0 to 1500
Pressure mode
G: gage pressure 1
A: absolute pressure 10
Note:
psi
psi
psi
psi
psi
psi
psi
psi
psi
psi
psi
x
x
x
Output signal
0:
0...10 V
1:
1...6 V
4:
4...20 mA
6:
0.5...4.5 V
7:
0...5 V
Fitting size
D: 1/8" BSPT
E: 1/4" BSPT
F: 3/8" BSPT
G: 1/2" BSPT
male,
male,
male,
male,
brass,
brass,
brass,
brass,
nickel
nickel
nickel
nickel
plated
plated
plated
plated
K:
L:
M:
N:
1/8"
1/4"
1/8"
1/4"
NPT male, brass
NPT male, brass
NPT male, SS 1.4305 (303)
NPT male, SS 1.4305 (303)
P:
Q:
R:
S:
G
G
G
G
1/8"
1/4"
3/8"
1/2"
(BSP)
(BSP)
(BSP)
(BSP)
male,
male,
male,
male,
U:
V:
W:
X:
G
G
G
G
1/8"
1/4"
3/8"
1/2"
(BSP)
(BSP)
(BSP)
(BSP)
female,
female,
female,
female,
Y:
G 1/8" (BSP) male, SS 1.4404 (316)
no optional fitting
brass,
brass,
brass,
brass,
nickel
nickel
nickel
nickel
brass,
brass,
brass,
brass,
plated
plated
plated
plated
nickel
nickel
nickel
nickel
plated
plated
plated
plated
Other pressure ranges and options are widely available.
Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
December 2008 / 508
6/6
www.sensortechnics.com
Similar pages