Total Power HPU60-D150K Accommodate universal ac source Datasheet

TOTAL POWER INT'L
UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC
19" COMPATIBLE EUROCARD 60 WATTS MULTIPLE OUTPUT
SWITCHING MODE POWER SUPPLIES HPU60 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
MEET IEC1000-3-2 HARMONIC CORRECTION
MEET UNIVERSAL SAFETY STANDARDS
19” COMPATIBLE EUROCARD FORMAT
EMI MEET EN 55022 & FCC CLASS B
CE MARKING COMPLIANCE
3U X 8HP X 160MM FOR VMEbus STANDARD
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: DIN 41612 at rear.
Input Frequency: 47-63Hz.
Inrush Current: Typ. ≤30.6A @ 230Vac.
Input Current: 0.73A @ 115Vac, 0.37A @ 230Vac.
Dielectric Withstand: Meet IEC950.
EMI/RFI: Meet EN 55022 & FCC B.
Power Indicator: Green LED.
Power Failure Signal: Installed.
Remote On/Off: Installed.
Power Factor Correction: Meet Harmonic Correction
IEC1000-3-2 .PF typ. 0.97-0.98.
Hold-up Time: 41mS @ 115Vac & 230Vac.
Earth Leakage: Less than 0.40mA @ 230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: DIN 41612 at rear.
Line Regulation: Typ. 0.5%.
Load Regulation: Main VO1 typ. ±1.0%.
Aux.VO2 typ. ±2.0% (Mag. Amp.)
typ. ±3.0%.(P.R.).
Aux.VO3 typ. ±3.0%(P.R.).
Noise & Ripple: Typ. 1% peak to peak.
OVP: Built-in at main VO1.
Adjustability: Available at VO1 & VO2.
Overload Protection (OLP): Fully protected against
output overload and short circuit.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 73%.
Switching Frequency: Fixed frequency 83K Hz.
Circuit Topology: Fixed frequency forward circuit.
Transient Response: Output voltage returns in less than
3mS following a 25% load change.
Safety Standard: IEC950 /UL1950 Class I.
Power Density: 1.52 Watts / Cubic Inch.
Operating Temperature: 0 to +50°C.
Storage Temperature: -25 to +85°C.
Temperature Coefficient: Typ. 0.03% /°C.
Cooling: Forced air flow is recommended for full load
>+40°C operation.
Construction format: 3U x 8HP(TE) x 160mm.
VMEbus standard Eurocard format.
Note: All measurements are at nominal input, full load, and +25°C unless otherwise specified.
OUTPUT VOLTAGE/CURRENT RATINGS CHART
DUAL OUTPUT
SINGLE OUTPUT
MAIN VO1 @#
Typ.
Volt.
18.0A
2.5V
15.0A
3.3V
12.0A
5.0V
10.0A
6.0V
5.0A
12.0V
4.0A
15.0V
3.0A
19.0V
2.5A
24.0V
1.3A
48.0V
MODEL NO.
HPU60-S025180
HPU60-S033150
HPU60-S050120
HPU60-S060100
HPU60-S120050
HPU60-S150040
HPU60-S190030
HPU60-S240025
HPU60-S480013
03/14/2002
AUX. VO2 ▲◇
Typ.
Volt.
6.0A
5.0V
3.0A
12.0V
3.0A
12.0V
2.5A
12.0V
2.5A
15.0V
2.0A
15.0V
1.5A
24.0V
1.4A
24.0V
MAIN VO1 @#
Typ.
Volt.
6.0A
3.0V
6.0A
3.0V
5.0A
5.0V
2.5A
12.0V
5.0A
5.0V
2.0A
15.0V
5.0A
5.0V
1.4A
24.0V
MODEL NO.
HPU60-D030E
HPU60-D030I
HPU60-D050I
HPU60-D120I
HPU60-D050K
HPU60-D150K
HPU60-D050M
HPU60-D240M
TRIPLE OUTPUT
MAIN VO1 @◇
Typ.
Volt.
MODEL NO.
HPU60-T050IE
(HPU60-30)
HPU60-T050KK
(HPU60-31)
HPU60-T050II
(HPU60-32)
HPU60-T030EI
HPU60-T030KK
HPU60-T030II
AUX. VO2 @▲◇ or●
Typ.
Volt.
AUX. VO3 ●◇
Typ.
Volt.
5.0A
5.0V
2.5A
12.0V
1.0A
5.0V
5.0A
5.0V
2.0A
15.0V
0.5A
15.0V
5.0A
5.0V
2.5A
12.0V
0.5A
12.0V
6.0A
6.0A
6.0A
3.0V
3.0V
3.0V
5.0A
2.0A
2.5A
5.0V
15.0V
12.0V
1.0A
0.5A
0.5A
12.0V
15.0V
12.0V
Symbol: "★" OVP built-in. "@" Adjustable. "▲" Magnetic Amplifier" "●" Installed with Post Regulator.
"◇" Floating(or isolated)output. "#" Remote sensing.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 720.0g (25.4Oz.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
AC INPUT
ASSIGNMENT
CNTR & Pin#
SINGLE OUTPUT
AC- AC- AC+VO1 +S -VO1 -S
L
N
G
28
30
32
4,6
Mating connector: DIN 41612-H15 Female
8
DUAL OUTPUT
NC
16,18,
12,14 10
24,26
+VO1 -VO1 +VO2 -VO2
4
6
8
10
Status/
Control
Log. P.
+VO1 -VO1 +VO2 -VO2 +VO3 -VO3 NC
Inh. Fail
TRIPLE OUTPUT
NC
12,14,16
18,24,26
4,6
8,10
12
14
16
18
24,26
20
22
Similar pages