MPS30 30W S i n g l e Ou t p ut f or M edi c al Ty pe series Universal AC input Low leakage current ≤ 0.3mA Protections: Short circuit / Overload / Over voltage / Over temperature Fixed switching frequency at 100KHz Low cost High reliability Model Number Output Volts Output Amps Ripple & NoiseEfficiency SINGLE OUTPUT MPS30-5 MPS30-12 MPS30-15 MPS30-24 MPS30-27 MPS30-48 5 Volts(DC) 12 Volts(DC) 15 Volts(DC) 24 Volts(DC) 27 Volts(DC) 48 Volts(DC) 5 Amps 2.5 Amps 2 Amps 1.2 Amps 1.1 Amps 0.6 Amps 80mV pk-pk 120mV pk-pk 150mV pk-pk 240mV pk-pk 240mV pk-pk 240mV pk-pk WWW.ASTRODYNETDI.COM 72% 75% 76% 77% 78% 78% OVP 5.5~6.75Volts(DC) 13.2~16.2Volts(DC) 16.5~20.25Volts(DC) 26.4~32.4Volts(DC) 29.7~36.45Volts(DC) 52.8~64.8Volts(DC) Min Load 0~5Amps 0~2.5Amps 0~2Amps 0~1.2Amps 0~1.1Amps 0~0.6Amps ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 MPS30 30W S i n g l e Ou t p ut f or M edi c al Ty pe INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: (cold start) Input Current Leakage current 90-264VAC / 120-370 Volts(DC) 47-63 Hz 30Amps @ 230VAC Input 0.8Amps max @ 115VAC 0.5Amps max @ 230VAC < 0.3mA / 230 VAC OUTPUT SPECIFICATIONS Voltage and Current Line Regulation Load Regulation Voltage Tolerance (Note 2) Ripple/Noise (Note 1) Hold Up Time @ FL Setup, Rise Time @ FL Over Temperature Protection Over Voltage Protection Over Current Protection See Selection Chart ±1.0%: 5~12Volts(DC) ± 5%: 15~48Volts(DC) ±2.0%: 5Volts(DC) 1%: 12~48Volts(DC) ±3% See Selection Chart 70mS @ 230VAC 12mS @ 115VAC 500mS, 30mS/230VAC 500mS. 30mS/115VAC Tj 135°C typ. (U1) detect on main conrol IC, auto recover See Selection Chart Hiccup mode, auto recover Above 105% rated output power Hiccup mode, auto recover GENERAL SPECIFICATIONS Safety Insulation Resistance EMI Harmonic Current Efficiency UL2601-1 TUV EN60601-1 IEC60601-1 approved ≥ 100MΩ Compliance to EN55011 (CISPR11) Class B Compliance to EN61000-3-2,-3 See Selection Chart series Isolation 4000VAC Input - Output 1500VAC Input - Ground Short Output - Ground EMS Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, medical level, criteria A ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity Temperature Coefficient MTBF Vibration -10°C to +60°C (See Derate Curve) -20°C to +85°C, 10~95% RH 20 to +90% RH non cond 0.03% / °C (0-50°C) 547KHrs min, MIL-HDBK-217F(25°C) 10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes PHYSICAL SPECIFICATIONS Size Millimeters 101.6 x 65.8 x 23.5 Inches 4” x 2.59” x 0.93” Weight 5.64 oz (160g) NOTE 1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. 2. Tolerance: includes set up tolerance, line regulation and load regulation. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 30W S i n g l e Ou t p ut f or M edi c al Ty pe WWW.ASTRODYNETDI.COM MPS30 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 30W S i n g l e Ou t p ut f or M edi c al Ty pe WWW.ASTRODYNETDI.COM MPS30 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458