Astrodyne MPS30-48 30w single output for medical type Datasheet

MPS30
30W S i n g l e Ou t p ut f or M edi c al Ty pe
series
Universal AC input
Low leakage current ≤ 0.3mA
Protections: Short circuit / Overload / Over voltage / Over
temperature
Fixed switching frequency at 100KHz
Low cost
High reliability
Model Number
Output Volts
Output Amps
Ripple & NoiseEfficiency
SINGLE OUTPUT
MPS30-5
MPS30-12
MPS30-15
MPS30-24
MPS30-27
MPS30-48
5 Volts(DC)
12 Volts(DC)
15 Volts(DC)
24 Volts(DC)
27 Volts(DC)
48 Volts(DC)
5 Amps
2.5 Amps
2 Amps
1.2 Amps
1.1 Amps
0.6 Amps
80mV pk-pk
120mV pk-pk
150mV pk-pk
240mV pk-pk
240mV pk-pk
240mV pk-pk
WWW.ASTRODYNETDI.COM
72%
75%
76%
77%
78%
78%
OVP
5.5~6.75Volts(DC)
13.2~16.2Volts(DC)
16.5~20.25Volts(DC)
26.4~32.4Volts(DC)
29.7~36.45Volts(DC)
52.8~64.8Volts(DC)
Min Load
0~5Amps
0~2.5Amps
0~2Amps
0~1.2Amps
0~1.1Amps
0~0.6Amps
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
MPS30
30W S i n g l e Ou t p ut f or M edi c al Ty pe
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ: (cold start)
Input Current
Leakage current
90-264VAC / 120-370 Volts(DC)
47-63 Hz
30Amps @ 230VAC Input
0.8Amps max @ 115VAC
0.5Amps max @ 230VAC
< 0.3mA / 230 VAC
OUTPUT SPECIFICATIONS
Voltage and Current
Line Regulation
Load Regulation
Voltage Tolerance (Note 2)
Ripple/Noise (Note 1)
Hold Up Time @ FL
Setup, Rise Time @ FL
Over Temperature Protection
Over Voltage Protection
Over Current Protection
See Selection Chart
±1.0%: 5~12Volts(DC)
± 5%: 15~48Volts(DC)
±2.0%: 5Volts(DC)
1%: 12~48Volts(DC)
±3%
See Selection Chart
70mS @ 230VAC
12mS @ 115VAC
500mS, 30mS/230VAC
500mS. 30mS/115VAC
Tj 135°C typ. (U1) detect on main conrol IC, auto recover
See Selection Chart
Hiccup mode, auto recover
Above 105% rated output power
Hiccup mode, auto recover
GENERAL SPECIFICATIONS
Safety
Insulation Resistance
EMI
Harmonic Current
Efficiency
UL2601-1
TUV EN60601-1
IEC60601-1 approved
≥ 100MΩ
Compliance to EN55011 (CISPR11) Class B
Compliance to EN61000-3-2,-3
See Selection Chart
series
Isolation
4000VAC Input - Output
1500VAC Input - Ground
Short Output - Ground
EMS
Compliance to
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2,
medical level, criteria A
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-10°C to +60°C (See Derate Curve)
-20°C to +85°C, 10~95% RH
20 to +90% RH non cond 0.03% / °C (0-50°C)
547KHrs min, MIL-HDBK-217F(25°C)
10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Millimeters
101.6 x 65.8 x 23.5
Inches
4” x 2.59” x 0.93”
Weight
5.64 oz (160g)
NOTE
1. Ripple and Noise are measured at 20MHz of bandwidth by using a
12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor.
2. Tolerance: includes set up tolerance, line regulation and load regulation.
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
30W S i n g l e Ou t p ut f or M edi c al Ty pe
WWW.ASTRODYNETDI.COM
MPS30
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
30W S i n g l e Ou t p ut f or M edi c al Ty pe
WWW.ASTRODYNETDI.COM
MPS30
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458