MASW-008330 V GaAs SP3T 2.5 V Switch DC - 3.0 GHz Rev. V1 Features Functional Schematic Low Voltage Operation: 2.5V Low Insertion Loss: 0.3 dB at 1 GHz 0.5 micron GaAs PHEMT Process Lead-Free 2 mm 8-Lead PDFN Package 100% Matte Tin Plating over Copper Halogen-Free ―Green‖ Mold Compound 260°C Reflow Compatible RoHS* Compliant version of MASWSS0028 100 pF Description M/A-COM’s MASW-008330 is a GaAs PHEMT MMIC single pole three throw (SP3T) switch in a lead-free 2 mm 8-lead PDFN package. The MASW008330 is ideally suited for applications where low control voltage, low insertion loss, high isolation, small size and low cost are required. RFC RF3 GND V3 V1 V2 RF1 RF2 100 pF 100 pF 100 pF Pin Configuration Pin No. Function Description Typical applications are for filter and antenna switching in handset systems that connect separate receive functions to a common antenna, as well as other related handset and general purpose applications. This part can be used in all systems operating up to 3 GHz requiring low control voltage. 1 RFC RF In/Out 2 GND RF Ground 3 V1 Control 1 4 RF1 RF In/Out 5 RF2 RF In/Out The MASW-008330 is fabricated using a 0.5 micron gate length GaAs PHEMT process. The process features full passivation for performance and reliability. 6 V2 Control 2 Ordering Information1 7 V3 Control 3 8 RF3 RF In/Out Absolute Maximum Ratings 3,4 Part Number Package Parameter Absolute Maximum MASW-008330-TR3000 3000 piece reel +32 dBm MASW-008330-TR3000 3000 piece reel Max Input Power (0.5 - 3 GHz, 2.5V Control) Sample Test Board (Includes 5 samples) Voltage ±8.5 volts MASW-008330-001SMB Operating Temperature -40°C to +85°C Storage Temperature -65°C to +150°C 1. Reference Application Note M513 for reel size information. 2 Truth Table V1 V2 V3 RFC RF1 RFC RF2 RFC RF3 0 1 0 On Off Off 1 0 0 Off On Off 0 0 1 Off Off On 3. Exceeding any one or combination of these limits may cause permanent damage to this device. 4. M/A-COM does not recommend sustained operation near these survivability limits. 2. 0 = 0 V ± 0.2 V, 1 = +2.5 V to +5 V. * Restrictions on Hazardous Substances, European Union Directive 2002/95/EC. 1 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASW-008330 GaAs SP3T 2.5 V Switch DC - 3.0 GHz Rev. V1 Electrical Specifications: TA = 25°C, VC = 0 V / 2.5 V, Z0 = 50 Ω 5 Parameter Test Conditions Units Min. Typ. Max. Insertion Loss 6 DC - 1 GHz 1 - 2 GHz 2 - 3 GHz dB dB dB — — — 0.3 0.5 0.75 0.4 0.6 1.0 Isolation DC - 1 GHz 1 - 2 GHz 2 - 3 GHz dB dB dB 19 13 10 24 18 14 — — — Return Loss DC - 2.5 GHz 2.5 - 3 GHz dB dB — — 25 20 — — IP3 Two Tone, +0 dBm/tone, 1 MHz Spacing, > 50 MHz dBm — 50 — P1dB — dBm — 21 — Trise, Tfall 10% to 90% RF, 90% to 10% RF nS — 13 — Ton, Toff 50% control to 90% RF and 50% control to 10% RF nS — 15 — Transients In Band mV — 30 — Control Current |VC| = 2.5V µA — 1 10 5. External DC blocking capacitors are required on all RF ports. 6. Insertion loss can be optimized by varying the DC blocking capacitor value, e.g. 100 pF for 100 - 500 MHz, 39 pF for 0.5 - 3 GHz. Lead Free 2 mm 8-lead PDFN † † Reference Application Note M538 for lead-free solder reflow recommendations. Meets JEDEC moisture sensitivity level 1 requirements. 2 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASW-008330 GaAs SP3T 2.5 V Switch DC - 3.0 GHz Rev. V1 Typical Performance Curves vs. Frequency and Temperature Isolation Insertion Loss 30 1.0 25 0.8 Insertion Loss +25C Insertion Loss +85C Insertion Loss -40C 20 0.6 15 0.4 10 Isolation +85C Isolation +25C Isolation -40C 5 0 0.5 1.0 0.2 1.5 2.0 2.5 3.0 0.0 0.5 1.0 Frequency (GHz) 1.5 2.0 2.5 3.0 Frequency (GHz) Return Loss Qualification Qualified to M/A-COM specification REL-201, Process Flow –2. 45 Return Loss +85C Return Loss +25C Return Loss -40C 40 35 Handling Procedures 30 Please observe the following precautions to avoid damage: 25 Static Sensitivity 20 15 0.5 1.0 1.5 2.0 Frequency (GHz) 2.5 3.0 Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity. Proper ESD control techniques should be used when handling these devices. 3 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MASW-008330 GaAs SP3T 2.5 V Switch DC - 3.0 GHz Rev. V1 M/A-COM Technology Solutions Inc. All rights reserved. Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM") products. These materials are provided by MACOM as a service to its customers and may be used for informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM assumes no responsibility for errors or omissions in these materials. MACOM may make changes to specifications and product descriptions at any time, without notice. MACOM makes no commitment to update the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise, to any intellectual property rights is granted by this document. THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS, WHICH MAY RESULT FROM THE USE OF THESE MATERIALS. 4 MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM customers using or selling MACOM products for use in such applications do so at their own risk and agree to fully indemnify MACOM for any damages resulting from such improper use or sale. M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support