Rhombus F-120 High frequency data line filter (4 lines - two coils) Datasheet

PARAMETER
F-120
UNITS
28
µH
Leakage Inductance
0.2 Max.
µH
Interwinding Capacitance
12 Max.
pF
0.20 +15%
Ω
High Frequency
Data Line Filter
500 Min.
VRMS
(4 Lines - Two Coils)
12
MHz
10k Min.
MΩ
250
mW
1
Inductance Min.
1
1
DC Resistance
Isolation (HI-POT)
SRF (Ref.)
Insulation Resistance
Power Rating
1
Tested at 100KHz and 100 mVRMS
Turns ratio 1:1 + 1%
Schematic Diagram
(Coil #1 Pins 1-16 & 3-14)
(Coil #2 Pins 5-12 & 7-10)
Physical Dimensions in inches (mm)
10/17/96
Rhombus
Industries Inc.
Transformers & Magnetic Products
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com