Sensors C/CT Series High Current AC, Snap-on Type Overview Applications The C/CT-1216 clamp-on current sensor can be used to measure currents in live wires. Typical applications include EMS current measurement, high performance distributions boards, power conditioners, power monitoring systems, inverters and industrial machineries. Benefits • • • • Compact and slim design Flat temperature characteristics Flame retardant RoHS compliant Ordering Information C/CT- 12 16 Series Rated Current (A) Diameter (mm) C/CT 12 = 120 16 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com One world. One KEMET SE0204_C_CT • 8/20/2015 1 • Compact, slim. Current transformation ratio • High performance from its unique design Output protection characteristics V • Flat temperature • Flame retardant Insulation resistance MΩ Operating temperature range 3000 7.5 V ≧ 100 ℃ Sensors – C/CT Series High Current AC, Snap-on Type Applications Strage temperature range ℃ • xEMS current measurement • High performance distribution boards Dimensions in mm • Shape Industrial machineries and Dimensions - 20℃~ +80℃ Output Characteristics (シロ) k K DC500V - 20 ~ +60 100000 SC L 120 50Hz/60Hz 0.1 ~ 120 50Hz/60Hz 1000+/ - 20 28.5 43 Io=50A 3000 7.5 V Load resistance(Ω) Comments 16 ≧ 100 f=50Hz 140 36.7 DC500V 10000 φ16 RL=60 Ω 23 1000 (クロ) l Output voltage [mV] Specifications - 20 ~ +60 100 60 1000 10 100 10 (mm) - 20℃~ +80℃ 1 0.001 Output Characteristics Output Characteristics 0.01 0.1 1 10 100 1000 Primary current [A] NEC TOKIN Sensors Vol.14 100000 17 Load resistance(Ω) 1000 10000 100 Output voltage [mV] 60production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data. ●All specifications in this catalog and ●Please request for a specification sheet for detailed product data prior to the purchase. 10 1000 in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog. ●Before using the product 2015.3.31 0000SENVOL14E1503H1 100 10 1 0.001 0.01 0.1 1 10 100 1000 Primary current [A] NEC TOKIN Sensors Vol.14 17 Environmental Compliance ge without notice. Prior to the purchase, please contact NEC TOKIN for updated product data. . ecautions listed in the printed version catalog. All C/CT sensors are RoHS compliant. 2015.3.31 0000SENVOL14E1503H1 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com SE0204_C_CT • 8/20/2015 2 Sensors – C/CT Series High Current AC, Snap-on Type Temperature Charateristics Operating Temperature Range (°C) Storage Temperature Range (°C) -20 to 60 -20 to 80 Table 1 – Ratings & Part Number Reference 1 2 Part Number Rated Current1 (A) Applicable Current1 (A) Output Voltage2 (mV) Current Transformation Ratio Output Protection (V) Insulation Resistance C/CT-1216 120 0.1 – 120 1,000+/-20 3,000 7.5 500 VDC to 100 MΩ 50Hz/60Hz Measurement conditions from output voltage: f = 50 Hz, R = 60 Ω, lo = 50 A Precautions Before Using High Alternating Current Sensors, Snap-on Type • Do NOT drop or apply any other mechanical stress. • Preliminary study is required when heating by current conduction. • Do NOT use the High Alternating Current Sensors, Snap-on Type, opened between secondary output terminals. Heat build-up in the magnetic core may occur, resulting in damages to the parts by melting of the coil. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com SE0204_C_CT • 8/20/2015 3 Sensors – C/CT Series High Current AC, Snap-on Type KEMET Corporation World Headquarters Europe Asia Southern Europe Sasso Marconi, Italy Tel: 39-051-939111 Northeast Asia Hong Kong Tel: 852-2305-1168 Mailing Address: P.O. Box 5928 Greenville, SC 29606 Skopje, Macedonia Tel: 389-2-55-14-623 Shenzhen, China Tel: 86-755-2518-1306 www.kemet.com Tel: 864-963-6300 Fax: 864-963-6521 Central Europe Landsberg, Germany Tel: 49-8191-3350800 Corporate Offices Fort Lauderdale, FL Tel: 954-766-2800 Kamen, Germany Tel: 49-2307-438110 North America Northern Europe Wyboston, United Kingdom Tel: 44-1480-273082 Taipei, Taiwan Tel: 886-2-27528585 Espoo, Finland Tel: 358-9-5406-5000 Southeast Asia Singapore Tel: 65-6701-8033 2835 KEMET Way Simpsonville, SC 29681 Northeast Wilmington, MA Tel: 978-658-1663 Southeast Lake Mary, FL Tel: 407-855-8886 Central Novi, MI Tel: 248-994-1030 Beijing, China Tel: 86-10-5877-1075 Shanghai, China Tel: 86-21-6447-0707 Seoul, South Korea Tel: 82-2-6294-0550 Penang, Malaysia Tel: 60-4-6430200 Bangalore, India Tel: 91-806-53-76817 Irving, TX Tel: 972-915-6041 West Milpitas, CA Tel: 408-433-9950 Mexico Guadalajara, Jalisco Tel: 52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com SE0204_C_CT • 8/20/2015 4 Sensors – C/CT Series High Current AC, Snap-on Type Disclaimer This product has been made available through a Private Label Agreement and a Development and Cross-Licensing Agreement between KEMET and NEC TOKIN to expand market and product offerings for both companies and their respective customers. For more information, please visit http://www.kemet.com/nectokin. All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com SE0204_C_CT • 8/20/2015 5