Kemet C/CT-1216 C/ct series high current ac, snap-on type Datasheet

Sensors
C/CT Series High Current AC, Snap-on Type
Overview
Applications
The C/CT-1216 clamp-on current sensor can be used to
measure currents in live wires.
Typical applications include EMS current measurement, high
performance distributions boards, power conditioners, power
monitoring systems, inverters and industrial machineries.
Benefits
•
•
•
•
Compact and slim design
Flat temperature characteristics
Flame retardant
RoHS compliant
Ordering Information
C/CT-
12
16
Series
Rated Current (A)
Diameter (mm)
C/CT
12 = 120
16
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
One world. One KEMET
SE0204_C_CT • 8/20/2015
1
• Compact, slim.
Current transformation ratio
• High
performance from its unique design
Output
protection characteristics
V
• Flat
temperature
• Flame
retardant
Insulation resistance
MΩ
Operating temperature range
3000
7.5 V
≧ 100
℃
Sensors – C/CT Series High Current AC, Snap-on Type
Applications
Strage temperature range
℃
• xEMS current measurement
• High performance distribution boards
Dimensions
in mm
• Shape
Industrial
machineries
and
Dimensions
- 20℃~ +80℃
Output Characteristics
(シロ)
k
K
DC500V
- 20 ~ +60
100000
SC
L
120
50Hz/60Hz
0.1 ~ 120
50Hz/60Hz
1000+/ - 20
28.5
43
Io=50A
3000
7.5 V
Load resistance(Ω)
Comments
16
≧ 100
f=50Hz
140
36.7
DC500V
10000
φ16
RL=60 Ω
23
1000
(クロ)
l
Output voltage [mV]
Specifications
- 20 ~ +60
100
60
1000
10
100
10
(mm)
- 20℃~ +80℃
1
0.001
Output
Characteristics
Output
Characteristics
0.01
0.1
1
10
100
1000
Primary current [A]
NEC TOKIN Sensors Vol.14
100000
17
Load resistance(Ω)
1000
10000
100
Output voltage [mV]
60production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
●All specifications in this catalog and
●Please request for a specification sheet
for detailed product data prior to the purchase.
10
1000 in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
●Before using the product
2015.3.31 0000SENVOL14E1503H1
100
10
1
0.001
0.01
0.1
1
10
100
1000
Primary current [A]
NEC TOKIN Sensors Vol.14
17
Environmental Compliance
ge without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
.
ecautions listed in the printed version catalog.
All C/CT sensors are RoHS compliant.
2015.3.31 0000SENVOL14E1503H1
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
SE0204_C_CT • 8/20/2015
2
Sensors – C/CT Series High Current AC, Snap-on Type
Temperature Charateristics
Operating Temperature
Range (°C)
Storage Temperature Range
(°C)
-20 to 60
-20 to 80
Table 1 – Ratings & Part Number Reference
1
2
Part Number
Rated
Current1
(A)
Applicable
Current1
(A)
Output
Voltage2
(mV)
Current
Transformation Ratio
Output
Protection
(V)
Insulation
Resistance
C/CT-1216
120
0.1 – 120
1,000+/-20
3,000
7.5
500 VDC to 100 MΩ
50Hz/60Hz
Measurement conditions from output voltage: f = 50 Hz, R = 60 Ω, lo = 50 A
Precautions
Before Using High Alternating Current Sensors, Snap-on Type
• Do NOT drop or apply any other mechanical stress.
• Preliminary study is required when heating by current conduction.
• Do NOT use the High Alternating Current Sensors, Snap-on Type, opened between secondary output terminals. Heat build-up in the
magnetic core may occur, resulting in damages to the parts by melting of the coil.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
SE0204_C_CT • 8/20/2015
3
Sensors – C/CT Series High Current AC, Snap-on Type
KEMET Corporation
World Headquarters
Europe
Asia
Southern Europe
Sasso Marconi, Italy
Tel: 39-051-939111
Northeast Asia
Hong Kong
Tel: 852-2305-1168
Mailing Address:
P.O. Box 5928
Greenville, SC 29606
Skopje, Macedonia
Tel: 389-2-55-14-623
Shenzhen, China
Tel: 86-755-2518-1306
www.kemet.com
Tel: 864-963-6300
Fax: 864-963-6521
Central Europe
Landsberg, Germany
Tel: 49-8191-3350800
Corporate Offices
Fort Lauderdale, FL
Tel: 954-766-2800
Kamen, Germany
Tel: 49-2307-438110
North America
Northern Europe
Wyboston, United Kingdom
Tel: 44-1480-273082
Taipei, Taiwan
Tel: 886-2-27528585
Espoo, Finland
Tel: 358-9-5406-5000
Southeast Asia
Singapore
Tel: 65-6701-8033
2835 KEMET Way
Simpsonville, SC 29681
Northeast
Wilmington, MA
Tel: 978-658-1663
Southeast
Lake Mary, FL
Tel: 407-855-8886
Central
Novi, MI
Tel: 248-994-1030
Beijing, China
Tel: 86-10-5877-1075
Shanghai, China
Tel: 86-21-6447-0707
Seoul, South Korea
Tel: 82-2-6294-0550
Penang, Malaysia
Tel: 60-4-6430200
Bangalore, India
Tel: 91-806-53-76817
Irving, TX
Tel: 972-915-6041
West
Milpitas, CA
Tel: 408-433-9950
Mexico
Guadalajara, Jalisco
Tel: 52-33-3123-2141
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
SE0204_C_CT • 8/20/2015
4
Sensors – C/CT Series High Current AC, Snap-on Type
Disclaimer
This product has been made available through a Private Label Agreement and a Development and Cross-Licensing Agreement between KEMET and NEC TOKIN to expand market
and product offerings for both companies and their respective customers. For more information, please visit http://www.kemet.com/nectokin.
All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and
verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are
not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use. The Information is intended for use only
by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still
occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not
be required.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
SE0204_C_CT • 8/20/2015
5
Similar pages