ETC2 OM3908SC Dual positive and negative fixed voltage regulators approved to desc drawing Datasheet

OM3901SC OM3903SC OM3905SC OM3907SC OM3909SC
OM3902SC OM3904SC OM3906SC OM3908SC
DUAL POSITIVE AND NEGATIVE FIXED VOLTAGE
REGULATORS APPROVED TO DESC DRAWING
Dual 5V, 12V and 15V, 1.5 Amp Fixed
Voltage Regulators In Single Hermetic
MO-078AA Package
FEATURES
•
•
•
•
•
•
•
Positive And Negative Regulators In One Package
Isolated Hermetic Package, JEDEC MO-078AA
Output Voltages 5V, 12V and 15V
Output Voltages Set Internally To ±1.0%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Similar to Industry Standards 7800 & 7900 Series
DESCRIPTION
This series of products offers a positive and a negative fixed voltage regulator in one
hermetically sealed, 5 pin package whose outline is similar to the industry standard
TO-247 package. With heat sinking, they can regulate over 1.5 Amp of output current
per device. Standard voltages are + or - 5V, 12V and 15V. Output voltages are
internally trimmed to ±1.0% of nominal voltage. These devices are ideally suited for
Military applications where small size and high reliability are required.
To order, use the following Omnirel part numbers to determine the required output
voltage of each regulator within one package.
PART NUMBER DESIGNATOR
Standard
Military Drawing Number
5962-8949002 XX
5962-8949003 XX
5962-8949004 XX
5962-8949005 XX
5962-8949006 XX
5962-8949007 XX
5962-8949008 XX
5962-8949009 XX
5962-8949001 XX
4 11 R0
Omnirel
Part Number
OM3901SC
OM3902SC
OM3903SC
OM3904SC
OM3905SC
OM3906SC
OM3907SC
OM3908SC
OM3909SC
3.3 - 107
Output Voltages
Positive Negative
+5V
-5V
+5V
-12V
+5V
-15V
+12V
-5V
+12V
-12V
+12V
-15V
+15V
-5V
+15V
-12V
+15V
-15V
3.3
OM3901SC - OM3909SC
INDIVIDUAL POSITIVE REGULATORS
ELECTRICAL CHARACTERISTICS +5 Volt
VIN = 10V, Io = 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
4.92
5.08
V
4.85
5.15
V
5
mV
VIN = 7.5V to 20V
Line Regulation
VRLINE
•
VIN = 7.5V to 20V
•
(Note 1)
VIN = 8.0V to 12V
•
Load Regulation
VRLOAD
IO = 5mA to 1.5 Amp
•
(Note 1)
IO = 250mA to 750 mA
•
Standby Current Drain
ISCD
Standby Current Drain
DISCD
Change With Line
(Line)
Standby Current Drain
DISCD
Change With Load
(Load)
mV
10
mV
12
mV
25
mV
6
mV
15
mV
6
mA
•
•
6.5
mA
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
Dropout Voltage
VDO
TA = 25°C, DVOUT = 100mV, IO = 1.0A
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = 35V
1.5
•
(Note 2)
DVIN
mV
4
VIN = 7.5V to 20V
Peak Output Current
Ripple Rejection
12
2.5
V
3.3
A
1.2
A
2.8
f =120 Hz, DVIN = 10V
66
•
DVOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
DVOUT
TA = 25°C, t = 1000 hrs.
75
(Note 3)
Dt
Output Noise Voltage
60
dB
(Note 3)
µV/V
RMS
ELECTRICAL CHARACTERISTICS +12 Volt
mV
VIN = 19V, Io = 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
11.88
12.12
V
11.64
12.36
V
18
mV
VIN = 14.5V to 27V
Line Regulation
VRLINE
•
VIN = 14.5V to 27V
•
(Note 1)
VIN = 16V to 22V
•
Load Regulation
VRLOAD
IO = 5mA to 1.5 Amp
•
(Note 1)
IO = 250mA to 750 mA
•
3.3
A
dB
Standby Current Drain
ISCD
Standby Current Drain
DISCD
Change With Line
(Line)
Standby Current Drain
DISCD
Change With Load
(Load)
mV
30
mV
32
mV
60
mV
20
mV
40
mV
6.0
mA
•
•
6.5
mA
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
•
Dropout Voltage
VDO
DVOUT = 100mV, IO = 1.0A
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = 35V
1.5
•
(Note 2)
DVIN
mV
9
VIN = 15V to 30V
Peak Output Current
Ripple Rejection
50
f =120 Hz, DVIN = 10V
2.5
V
3.3
A
1.2
A
2.8
61
•
DVOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
DVOUT
TA = 25°C, t = 1000 hrs.
120
(Note 3)
Dt
Output Noise Voltage
A
dB
54
dB
(Note 3)
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
3.3 - 108
OM3901SC - OM3909SC
ELECTRICAL CHARACTERISTICS +15 Volt
VIN = 23V, Io = 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
14.8
15.2
V
14.6
15.4
V
20
mV
50
mV
VIN = 18.5V to 30V
Line Regulation
VRLINE
•
VIN = 17.5V to 30V
•
(Note 1)
VIN = 20V to 26V
Load Regulation
VRLOAD
(Note 1)
15
mV
•
25
mV
35
mV
•
75
mV
21
mV
•
45
mV
IO = 5mA to 1.5 Amp
IO = 5mA to 1.0 Amp
IO = 250mA to 750 mA
Standby Current Drain
ISCD
Standby Current Drain
DISCD
Change With Line
(Line)
Standby Current Drain
DISCD
Change With Load
(Load)
6.0
mA
6.5
mA
VIN = 18.5V to 30V
•
•
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
Dropout Voltage
VDO
TA = 25°C, DVOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = 35V
•
(Note 2)
Ripple Rejection
1.5
DVIN
2.5
V
3.3
A
1.2
A
2.8
f =120 Hz, DVIN = 10V
54
•
DVOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
DVOUT
TA = 25°C, t = 1000 hrs.
150
(Note 3)
Dt
Output Noise Voltage
A
dB
52
dB
(Note 3)
µV/V
RMS
ELECTRICAL CHARACTERISTICS -5 Volt
mV
VIN = -10V, Io = 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
-4.95
-5.05
V
-4.85
-5.15
V
12
mV
25
mV
VIN = -7.5V to -20V
Line Regulation
VRLINE
•
VIN = -7.5V to -20V
•
(Note 1)
VIN = -8.0V to -12V
Load Regulation
VRLOAD
5
mV
•
12
mV
20
mV
•
25
mV
15
mV
•
30
mV
IO = 5mA to 1.5 Amp
(Note 1)
IO = 250mA to 750 mA
Standby Current Drain
ISCD
Standby Current Drain
DISCD
Change With Line
(Line)
Standby Current Drain
DISCD
Change With Load
(Load)
2.5
mA
3.0
mA
VIN = -7.0V to -20V
•
•
0.4
mA
IO = 5mA to 1000mA
•
0.4
mA
•
Dropout Voltage
VDO
DVOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = -35V
DVIN
f =120 Hz, DVIN = -10V
•
(Note 2)
Ripple Rejection
1.5
2.5
V
3.3
A
1.2
A
2.8
63
•
DVOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
DVOUT
TA = 25°C, t = 1000 hrs.
75
(Note 3)
Dt
Output Noise Voltage
A
dB
60
dB
(Note 3)
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN =+35V, positive regulator; .VIN = -35V, negative regulator.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
3.3 - 109
3.3
OM3901SC - OM3909SC
ELECTRICAL CHARACTERISTICS -12 Volt
VIN = -19V, Io = 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
-11.88
-12.12
V
-11.64
-12.36
V
20
mV
50
mV
VIN = -14.5V to -27V
Line Regulation
VRLINE
•
VIN = -14.5V to -27V
•
(Note 1)
VIN = -16V to -22V
Load Regulation
VRLOAD
10
mV
•
30
mV
32
mV
•
60
mV
16
mV
•
30
mV
IO = 5mA to 1.5 Amp
(Note 1)
IO = 250mA to 750 mA
Standby Current Drain
ISCD
Standby Current Drain
DISCD
Change With Line
(Line)
Standby Current Drain
DISCD
Change With Load
(Load)
3.5
mA
4.0
mA
VIN = -14.5V to -27V
•
•
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
•
1.8
V
Dropout Voltage
VDO
DVOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C, IO = 5mA to 1A
Short Circuit Current
IDS
VIN = -35V
DVIN
f =120 Hz, DVIN = -10V
•
(Note 2)
Ripple Rejection
1.5
3.3
A
1.2
A
2.8
56
•
DVOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
DVOUT
TA = 25°C, t = 1000 hrs.
120
(Note 3)
Dt
Output Noise Voltage
53
dB
(Note 3)
µV/V
RMS
ELECTRICAL CHARACTERISTICS -15 Volt
mV
VIN = -23V, Io = 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
-14.85
-15.15
V
-14.55
-15.45
V
25
mV
50
mV
VIN = -17.5V to -30V
Line Regulation
VRLINE
•
VIN = -17.5V to -30V
•
(Note 1)
VIN = -20V to -26V
Load Regulation
VRLOAD
15
mV
•
25
mV
35
mV
•
75
mV
21
mV
•
45
mV
IO = 5mA to 1.5 Amp
(Note 1)
IO = 250mA to 750 mA
Standby Current Drain
3.3
A
dB
ISCD
Standby Current Drain
DISCD
Change With Line
(Line)
Standby Current Drain
DISCD
Change With Load
(Load)
6.0
mA
6.5
mA
VIN = -17.5V to -30V
•
•
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
•
Dropout Voltage
VDO
DVOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = -35V
•
(Note 2)
Ripple Rejection
1.5
DVIN
f =120 Hz, DVIN = -10V
2.5
V
3.3
A
1.2
A
2.8
53
•
DVOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
DVOUT
TA = 25°C, t = 1000 hrs.
150
(Note 3)
Dt
Output Noise Voltage
A
dB
50
dB
(Note 3)
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
3.3 - 110