AC/DC Converter LH05 Series 5W, AC-DC converter FEATURES Universal input range:85~264VAC, 100~370VDC Regulated output, low ripple and noise Over-current, short circuit and over- voltage protection Plastic case, meets UL94V-0 Meet UL60950,EN60950 standards 3 years product warranty PCB mounting, Chassis mounting, DIN-Rail mounting E235235 RoHS LH05 series -----a compact size power converter offered by Mornsun. It features universal input voltage, taking both DC and AC input voltage, low power consumption, high efficiency, high reliability, safer isolation. It offers good EMC performance, which meet IEC/EN61000-4, CISPR22/EN55022, UL60950 and EN60950 standards, and it’s widely used in industrial, office and civil applications. For harsh EMC environment, the application circuit in the datasheet is strongly recommended. Selection Guide Certification Part No.* Output Power (Vo1/Io1) (Vo2/Io2) 3.3V/1250mA -- 5V/1000mA -- LH05-10B09 9V/550mA LH05-10B12 12V/420mA LH05-10B15 15V/330mA LH05-10B03 4W LH05-10B05 UL/CE Efficiency (230VAC, %/Typ.) Max. Capacitive Load(µF) Vo1 Vo2 70 8100 -- 75 6800 -- -- 77 1200 -- -- 79 1000 -- -- 80 680 -- LH05-10B24 24V/230mA -- 82 270 -- LH05-10A05 +5V/500mA -5V/500mA 75 1480 1480 LH05-10A12 +12V/210mA -12V/210mA 79 130 130 LH05-10A15 +15V/160mA -15V/160mA 79 110 110 LH05-10A24 -- Nominal Output Voltage and Current +24V/100mA -24V/100mA 80 16 16 LH05-10C0505-01 5W 5V/800mA ±5V/100mA 70 2400 370 LH05-10C0512-01 5V/600mA ±12V/100mA 73 1600 170 LH05-10C0515-01 5V/600mA ±15V/80mA 74 1760 80 LH05-10C0524-01 5V/600mA ±24V/50mA 75 1170 50 LH05-10D0505-01 5V/900mA 5V/100mA 71 3360 370 LH05-10D0512-01 5V/750mA 12V/100mA 73 2400 170 LH05-10D0515-01 5V/700mA 15V/100mA 73 2160 170 LH05-10D0524-01 5V/600mA 24V/100mA 75 3000 100 Note: *About LH05-10AXX,we use Vo2 as sampling feedback;and all others use Vo1 as sampling feedback. Input Specifications Item Input Voltage Range Input frequency Operating Conditions Min. Typ. Max. Unit AC input 85 -- 264 VAC DC input 100 -- 370 VDC 47 -- 63 Hz 2015.08.24-B/3 Page 1 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LH05 Series Input current Inrush current 115VAC -- 230VAC 115VAC 230VAC -- 0.125 -- -- 0.08 -- 10 -- -- 20 -- A Leakage current 0.3mA RMS typ./230VAC/50Hz Recommended External Input Fuse(Special package series include fuse) 1A/250V, slow fusing Hot Plug Unavailable Output Specifications Item Operating Conditions Output Voltage Accuracy Main circuit Line Regulation Full load 10%-100% load Load Regulation Min. Typ. Max. -- ±2 -- Main circuit -- ±0.5 -- Auxiliary circuit -- ±1.5 -- Single output -- ±1 -- Dual output(balanced load) -- ±2 -- Main circuit -- ±3 -- Auxiliary circuit -- ±5 -- Isolated and separated twin output (balanced load) Main circuit -- ±3 -- Auxiliary circuit -- ±5 -- 50 150 mV ±0.02 -- %/°C 20MHz bandwidth (peak-peak value) -- Temperature Coefficient Main circuit -- Short Circuit Protection Continuous, self-recovery ≥110%Io self-recovery Over-current Protection Main circuit 3.3 / 5VDC Output ≤7.5VDC 9VDC Output ≤13VDC 12 /15VDC Output ≤20VDC 24VDC Output Min. Load Hold-up Time % Isolated triple output (balanced load) Ripple & Noise* Over-voltage Protection Unit ≤30VDC Single output models 0 -- -- Dual output models (balanced load) 10 -- -- Isolated and separated twin output (balanced load) 10 -- -- Isolated triple output (balanced load) 10 -- -- 115VAC input -- 15 -- 230VAC input -- 80 -- % ms Note: * Ripple and noise are measured by “parallel cable” method, please see AC-DC Converter Application Notes for specific operation. General Specifications Item Operating Conditions Min. Test time: 1min 3000 -- -- Operating Temperature -25 -- +70 Storage Temperature -25 -- +105 -- -- 95 Isolation Voltage Input-output Storage Humidity Welding Temperature Switching Frequency Power Derating Typ. Max. Unit VAC %RH Wave-soldering 260±5℃; time:5~10s Manual-welding 360±10℃; time:3~5s LH05-10A24 -- 65 -- Others -- -- 140 -25℃~-10℃ 2.0 -- -- 55℃~+70℃ 4.0 -- -- Safety Standard IEC60950/EN60950/UL60950 Safety Certification EN60950/UL60950 2015.08.24-B/3 °C kHz %/°C Page 2 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LH05 Series Safety Class CLASS I MTBF MIL-HDBK-217F@25°C > 300,000 h Physical Specifications Casing Material Black flame-retardant and heat-resistant plastic (UL94-V0) Dimension Weight Horizontal package 48.50*36.00*20.50 mm A2 chassis mounting 96.10*54.00*29.00 mm A3 chassis mounting 99.00*54.00*29.00 mm A4 Din-Rail mounting 96.10*54.00*33.60 mm Horizontal package/A2 chassis mounting /A3 chassis mounting/A4 Din-Rail mounting 55g/100g/100g/140g(Typ.) Cooling method Free air convection EMC Specifications EMI EMS CE CISPR22/EN55022, CLASS B RE CISPR22/EN55022, CLASS B ESD IEC/EN61000-4-2 ±6KV/±8KV Perf. Criteria B RS IEC/EN61000-4-3 10V/m perf. Criteria A IEC/EN61000-4-4 ±2KV perf. Criteria B IEC/EN61000-4-4 ±4KV (See Fig. 5 for recommended circuit) perf. Criteria B IEC/EN61000-4-5 ±1KV/±2KV perf. Criteria B IEC/EN61000-4-5 ±2KV/4KV (See Fig. 5 for recommended circuit) perf. Criteria B CS IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A PFM Immunities of voltage dip, drop and short interruption IEC/EN61000-4-8 10A/m perf. Criteria A EFT Surge EMS IEC/EN61000-4-11 0%-70% perf. Criteria B Temperature Derating Curve 100 70 Inpu t voltage: 85~264VAC 100~370VDC 40 20 Output Power Percent age(%) Output Power Perc entage(%) Product Characteristic Curve Input Voltage Derating Curve 100 80 75 60 40 Ambient temperatu re: 25℃ 20 264 VAC 240 370 VDC 340 Inpu t Voltage Note: ①When input 85~100VAC/240~264VAC/100~120VDC/340~370VDC, it need to be voltage derated on basis of temperature derating; ②This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE. -25 -10 55 70 Ambient Temperatu re(℃ ) 85 100 100 120 2015.08.24-B/3 Page 3 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LH05 Series Design Reference 1. Typical application circuit F US E A C(L) N TC A C(L) +Vo C1 C2 A C(L) L OA D A C(N) A C(N ) F US E TV S AC DC MO V NTC +Vo A C(L) MO V A C(N ) - Vo - Vo F USE NTC + A C(L) M OV A C(N ) ACDC A C(N) C1 C 2 TV S1 RL NTC C3 C 4 TV S 2 RL RL C1 C 2 TV S1 RL C3 C 4 TV S2 RL C5 C 6 TV S3 RL - ACDC A C(N) AC(N) + Vo2 + Vo1 AC(L) MO V +Vo2 C om C3 C 4 TV S2 -Vo2 RL Fig. 3: LH05-10Dxx (Isolate Twin Output) series typical application circuit Model LH05-10B03 LH05-10B05 LH05-10B09 LH05-10B12 LH05-10B15 LH05-10B24 LH05-10A05 LH05-10A12 LH05-10A15 LH05-10A24 LH05-10C0505-01 LH05-10C0512-01 LH05-10C0515-01 LH05-10C0524-01 LH05-10D0505-01 LH05-10D0512-01 LH05-10D0515-01 LH05-10D0524-01 F USE AC(L) Vo1 - - C 2 TV S 1 Fig. 2: LH05-10Axx (Dual Output) series typical application circuit Fig. 1: Typical application circuit A C(L) C1 AC DC A C(N) C om C2(µF) 330 330 120 120 68 68 120 68 47 10 220 120 120 120 220 220 120 120 C4(µF) Fig. 4: LH05-10Cxx (Triple Output) series typical application circuit C6(µF) 120 68 47 10 22 22 22 22 22 22 22 22 TVS1 SMBJ7.0A SMBJ7.0A SMBJ12A SMBJ20A SMBJ20A SMBJ30A SMBJ7.0A SMBJ20A SMBJ20A SMBJ30A SMBJ7.0A SMBJ7.0A SMBJ7.0A SMBJ7.0A SMBJ7.0A SMBJ7.0A SMBJ7.0A SMBJ7.0A 22 22 22 22 TVS2 TVS3 SMBJ7.0A SMBJ20A SMBJ20A SMBJ30A SMBJ7.0A SMBJ20A SMBJ20A SMBJ30A SMBJ7.0A SMBJ20A SMBJ20A SMBJ30A SMBJ7.0A SMBJ20A SMBJ20A SMBJ30A Note: Note: Output filtering capacitors C2, C4, C6 are electrolytic capacitors, it is recommended to use high frequency and low impedance electrolytic capacitor. For capacitance and current of capacitor please refer to manufacture’s datasheet. Capacitor withstand voltage derating should be 80% or above. C1,C3, C5 are ceramic capacitors, which is used to filter high-frequency noise. TVS is a recommended component to protect post-circuits if converter fails. External input NTC is recommended to use 5D-9. External input FUSE model is recommended to use 1A/250V slow fusing,External input MOV model is recommended to use S14K300. 2. EMC solution-recommended circuit Can u se M OR NSUN ' s FC-LX1 D FUSE LDM LCM AC( L) AC( L) +Vo C1 CY1 TVS1 RL + ACDC MOV1 CX CY2 AC( N) C2 -Vo AC( N) Fig 5: EMC Recommended circuit with higher requirements 2015.08.24-B/3 Page 4 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LH05 Series Element model Recommended value MOV1 S14K300 CY1 , CY2 1000pF/400VAC CX 0.1μF/275VAC LCM 10mH, recommended to use MORNSUN’s FL2D-Z5-103 LDM 4.7μH/2A FC-LX1D 2KV/4KV EMC filter FUSE 2A/250V slow fusing, necessary 3. For more information about Mornsun EMC Filter products, please visit www.mornsun-power.com to download the Selection Guide of EMC Filter Dimensions and Recommended Layout 2015.08.24-B/3 Page 5 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LH05 Series LHXXA2 Dimensions LHXXA3 Dimensions 2015.08.24-B/3 Page 6 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LH05 Series LHXXA4 Dimensions Note: 1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com. Packing bag number of Horizontal package : 58220007 (LH05), the Packing bag number of A2/A3/A4 package:58220010; 2. If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all parameters in the datasheet; 3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25 ℃, humidity<75% with nominal 4. 5. 6. 7. input voltage and rated output load; All index testing methods in this datasheet are based on our Company’s corporate standards; The performance parameters of the product models listed in this manual are as above, but some parameters of non-standard model products may exceed the requirements mentioned above. Please contact our technicians directly for specific information; We can provide product customization service; Specifications are subject to change without prior notice. Mornsun Guangzhou Science & Technology Co., Ltd. Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China Tel: 86-20-38601850-8801 Fax: 86-20-38601272 E-mail: [email protected] 2015.08.24-B/3 Page 7 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation