ILPA50VW SERIES 50W Water-Proof Constant Voltage LED Driver – – – – – – – 2 Year Warranty Wide Input Voltage 90 to 264VAC, 47 to 63Hz Constant Output Voltage Available for 12VDC and 24VDC Over Voltage, Short Circuit, and Over Temperature Protection High Efficiency (up to 86%) Active Power Factor Correction (PFC) (87% typical) IP67 Waterproof Rating, Metal Housing Comply with UL8750 & EN61347 Safety Regulation (Pending) Approvals: Single Output Max. Part Number Output Voltage Output Current ILPA50VW-050S012SS 12 VDC 3.00 A ILPA50VW-050S024SS 24 VDC 2.10 A Item -050S012SS, -050S024SS use Class 2 output (USR & CNR). Efficiency (220VAC, Full Load) 84% 86% Over Voltage Protection Min / Typ / Max 14V / 16V / 18V 29V / 33V / 36V Max. Output Power 36W 50W Electrical Characteristics Parameter Input Voltage Input Frequency Output Power Range Input Current (Low Line) Input Current (High Line) High Line Inrush Current Power Factor Correction Power Factor Correction Efficiency No-Load Power Consumption Line Regulation Load Regulation Over Voltage Protection Over Current Protection Over Temperature Protection Short Circuit Protection Output Overshoot / Undershoot Start Up Time Ripple & Noise (Peak to Peak) Test Conditions Operating Voltage Min. 90 47 0 Typ. Max. Unit 264 VAC 63 Hz Vin=90 to 264VAC 50 W Io=Full load, Vin=115VAC 0.7 A Io=Full load, Vin=230VAC 0.35 A Io=Full load, 25°C, Cool start, Vin=230VAC 65 A Vin=110VAC 86 87 % Vin=220VAC 84 85 % Io=Full Load, Vin=230VAC 86 % No Load, VIn=230VAC 1 W Io=Full Load 1 % Vin=230VAC 3 % Latch mode. The power unit shall return to normal operation only after the power is turn-on again. (Please refer to output table.) 120 130 170 % Io 110 °C No damage shall occur when any output operating in a short circuit condition. The power supply shall be self-recovery when the fault condition is removed. When power on or off 10 % Io=Full Load, Vin=100VAC 3 S Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 uF ceramic capacitor and a 10 2 % Vo uF electrolytic capacitor. Min. Typ. Conditions Parameter Test Conditions Operating Temperature Humidity: 10% RH to 100% RH Storage Temperature Humidity: 5% RH to 100% RH Operation temperature at 25°C, calculated per MIL-HDBK-217F Life Time at 25°C ambient temperature No output power derating from -35°C to 70°C -35 -40 0.3M 0.08M Max. Unit 60 85 °C °C Hours Hours Approvals and Compliance Parameter EMI EMS Safety UL/c-UL, T-mark, CE Environmental Compliance Waterproof Standards EN55015 EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4.3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-1-1, EN61547 UL8750 Compliant to UL1310 Class 2, UL1012, UL935, CSA-C22.2 No. 0, CSA-C22.2 No. 107.1, CSA-C22.2 No.250.0, EN61347-1,EN61347-2-13 RoHS IP67 Rating Mechanical Parameter Dimension Net Weight Specification 162x34.5x42.5mm (6.38x1.36x1.67 inches) 460g approx.