MPD MPM-03S-03MM 3w output power Datasheet

MPM-03MM Series
Miniature 1 x 1 Inch
3W, Single Output
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 3W Output Power
• Miniature 1 x 1 Inch Case
• Universal 85-264 VAC Input
• EN 60950 Approved
• Six Standard Models
• Meets EN 55022 B
• Meets IEC Safety Class II
• >1.20 MHour MTBF
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Voltage Range
Input Frequency
Input Current
Inrush Current, See Note 1
No Load Power Consumption
Min.
Typ.
85
120
47
See Model Selection Guide
115 VAC
230 VAC
See Note 2
Max.
264
370
63
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
Max.
Units
±2.0
±1.0
±1.0
70
%
%
%
m V P-P
mS
%/°C
%VOUT
%VOUT
15.0
25.0
150
Units
VAC
VDC
Hz
A Pk
mW
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Overshoot
Short Circuit Protection, See Note 4
Overload Protection
VIN = Min to Max
IOUT = 0% to 100%
115 VAC
8.0
See Note 3
125
±0.05
190
5.0
Continuous (Auto-Recovery)
See Note 5 135
150
%W
General
Parameter
Isolation Voltage
Isolation Resistance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFM
Voltage Dips
Interruptions
Conditions
Input to Output, 60S
500 VDC
Min.
3,000
100
Typ.
Max.
65
Standard
EN 55014, EN 55024
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 61000-4-11
MicroPower Direct
Environmental
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Physical
Case Size
Case Material
Weight
Criteria
A
A
A
A
A
A
A
B
Units
VAC
M
kHz
Level
Class B
Class B
±8 kV Air
10V/m
±2 kV
±1 kV
10 Vrms
30A/m
30% 10 mS
95% 5,000 mS
Conditions
Min.
Typ.
Max.
-25
+25
+70
-40
+85
Free Air Convection (See Derating Curve on Page 2)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
See Mechanical Diagram (Page 2)
Non-Conductive Black Plastic (UL94-V0)
0.59 Oz (17.4g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign 1.20
EN 60950
IEC 60536 Class II
www.micropowerdirect.com
Max.
Units
MHours
www.micropowerdirect.com
Model Selection Guide
Model
Number
MPM-03S-03MM
MPM-03S-05MM
MPM-03S-09MM
MPM-03S-12MM
MPM-03S-15MM
MPM-03S-24MM
Input
Current
(mA Typ)
Output
Current (mA)
Voltage
115 VAC
(VDC)
Max.
Min.
Peak
62
61
57
56
56
56
3.3
5.0
9.0
12.0
15.0
24.0
900
600
333
250
200
125
0.0
0.0
0.0
0.0
0.0
0.0
1,170
780
430
320
260
160
Notes:
1. Inrush current is given for a cold start at 25°C.
2. No load power consumption meets the standby power consumption limits in
the European ERP Directive 2009/125/EC.
3. Over voltage protection is provided by a zener diode clamp.
4. Output short circuit protection is provided by a “hiccup mode” circuit. The
unit recovers automatically when the fault condition is removed.
5. Output overload protection is provided by a fold back current limiting circuit
with auto-recovery. A long-term overload could damage the unit.
6. Operation at no-load will not damage these units. However, they may not meet
all specifications.
7. Peak load is specified as lasting <30s with a maximum duty cycle of 10%
The average power should not exceed the maximum power rating.
8. It is recommended that an external slow blow fuse also be used on the input
for protection. See the table above for the correct rating.
Fuse
Efficiency Capacitive
Rating
Load
(%, Typ)
(µF Max) Slow-Blow
(mA)
70
72
77
78
78
78
1,200
820
470
330
270
180
Other outputs may be available
Contact the factory for details at:
[email protected]
1,000
1,000
1,000
1,000
1,000
1,000
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Function
1
2
3
4
5
AC-Neutral
AC-Line
No Connection
-VOUT
+VOUT
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]