DRTR5V0U4LP16 4 CHANNEL LOW CAPACITANCE TVS DIODE ARRAY Product Summary Features ADVANCED INFORMATION VBR (min) 6V IPP (max) 6A CT (typ) 1.0pF Description This new generation TVS is designed to protect sensitive electronics from the damage due to ESD. The combination of small size and high ESD surge capability makes it ideal for use in portable applications such as cellular phones, digital cameras, and MP3 players. Mechanical Data Applications Cellular Handsets Portable Electronics Computers and Peripheral Provides ESD Protection per IEC 61000-4-2 Standard: Air ±30kV, Contact ±30kV 4 Channels of ESD Protection Low Channel Input Capacitance Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2) Halogen and Antimony Free. “Green” Device (Note 3) Case: U-DFN1616-6 Case Material: Molded Plastic, “Green” Molding Compound. UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020 Terminals: NiPdAu over Copper Leadframe. Solderable per MIL-STD-202, Method 208 e4 Weight: 0.002 grams (Approximate) U-DFN1616-6 Bottom View Top View Device Schematic Ordering Information (Note 4) Product DRTR5V0U4LP16-7 Notes: Compliance Standard Marking SN Reel Size (inches) 7 Tape Width (mm) 8 Quantity per Reel 3,000/Tape & Reel 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. 2. See http://www.diodes.com for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green" and Lead-free. 3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. 4. For packaging details, go to our website at http://www.diodes.com. Marking Information SN Date Code Key Year Code Month Code 2014 B Jan 1 YM 2015 C Feb 2 DRTR5V0U4LP16 Document number: DS37969 Rev. 1 - 2 Mar 3 SN = Product Type Marking Code YM = Date Code Marking Y = Year (ex: B = 2014) M = Month (ex: 9 = September) 2016 D Apr 4 May 5 2017 E Jun 6 1 of 4 www.diodes.com 2018 F Jul 7 Aug 8 2019 G Sep 9 Oct O 2020 H Nov N Dec D November 2015 © Diodes Incorporated DRTR5V0U4LP16 Maximum Ratings (@TA = +25°C, unless otherwise specified.) Characteristic Peak Pulse Current ESD Protection – Contact Discharge VESD_Contact VESD_Air Value 6 ±30 Unit A kV Conditions 8/20µs (Note 7) Standard IEC 61000-4-2 ±30 kV Standard IEC 61000-4-2 Thermal Characteristics Characteristic Power Dissipation (Note 5) Thermal Resistance, Junction to Ambient TA = +25°C Operating and Storage Temperature Range Symbol PD RθJA TJ, TSTG Value 300 417 -55 to +150 Unit mW °C/W °C Electrical Characteristics (@TA = +25°C, unless otherwise specified.) Characteristic Reverse Standoff Voltage Channel Leakage Current (Note 6) Reverse breakdown voltage Clamping Voltage, Positive Transients (Note 7) Channel Input Capacitance (Note 8) Dynamic Resistance Notes: Symbol VRWM IR VBR VC Min — — 6.0 — Typ — — — 10 Max 5.5 100 — 12 Unit V nA V V CT — 1.0 1.5 pF RDYN — 0.9 — Ω Test Conditions VR = 5V, Any I/O to GND IR = 1mA, from pin 5 to pin 2 IPP = 1A, tp = 8/20μs VR = 0V, f = 1MHz, Any I/O to GND IPP = 1A, tp = 8/20μs 5. Device mounted on FR-4 PCB pad layout (2oz copper) as shown on Diodes, Inc. suggested pad layout AP02001, which can be found on our website at http://www.diodes.com. 6. Short duration pulse test used to minimize self-heating effect. 7. Clamping voltage value is based on an 8x20µs peak pulse current (Ipp) waveform. 8. Measured from any I/O to GND. 9. For information on the impact of Diodes' USB 2.0 compatible ESD protectors on signal integrity including eye diagram plots, please refer to AN77 at the following URL: http://www.diodes.com/destools/appnote_dnote.html. 400 100 Note 5 PEAK PULSE DERATING % OF PEAK POWER OR CURRENT 350 PD, POWER DISSIPATION (mW) ADVANCED INFORMATION ESD Protection – Air Discharge Symbol IPP 300 250 200 150 100 75 50 25 50 0 0 0 25 50 75 100 125 150 TA, AMBIENT TEMPERATURE (°C) Figure 1 Power Derating Curve DRTR5V0U4LP16 Document number: DS37969 Rev. 1 - 2 175 2 of 4 www.diodes.com 0 25 50 75 100 125 150 175 200 TA, AMBIENT TEMPERATURE (°C) Figure 2 Pulse Derating Curve November 2015 © Diodes Incorporated Peak Value Ipp Half Value Ipp/2 50 8x20 Waveform as defined by R.E.A. 20 0 60 40 IF, INSTANTANEOUS FORWARD CURRENT (mA) IPP, PEAK PULSE CURRENT (%Ipp) 100 0 t, TIME (s) Figure 3 Pulse Waveform 1,000 100 TA = 150°C 10 TA = 125°C 1 TA = 85°C 0.1 TA = 25°C TA = -55°C 0.01 0.001 0.2 0.4 0.6 0.8 1.0 1.2 VF, INSTANTANEOUS FORWARD VOLTAGE (V) Figure 4 Typical Forward Characteristics 2.0 100 1.8 TA = 150°C 10 TA = 125°C TA = 85°C 1 TA = 25°C TA = -55°C CT, TOTAL CAPACITANCE (pF) IR, INSTANTANEOUS REVERSE CURRENT (nA) ADVANCED INFORMATION DRTR5V0U4LP16 f = 1MHz 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.1 0.0 0 1 2 3 4 5 VR, INSTANTANEOUS REVERSE VOLTAGE (V) Figure 5 Typical Reverse Characteristics 0 1 2 3 4 5 VR, REVERSE VOLTAGE (V) Figure 6 Typical Total Capacitance vs. Reverse Voltage Package Outline Dimensions Please see AP02002 at http://www.diodes.com/datasheets/ap02002.pdf for the latest version. A U-DFN1616-6 Dim Min Max Typ A 0.545 0.605 0.575 A1 0 0.05 0.02 A3 0.13 b 0.20 0.30 0.25 D 1.55 1.675 1.60 D2 1.10 1.30 1.20 E 1.55 1.675 1.60 e 0.50 E2 0.30 0.50 0.40 L 0.275 0.375 0.325 All Dimensions in mm A3 A1 D e E E2 L b D2 DRTR5V0U4LP16 Document number: DS37969 Rev. 1 - 2 3 of 4 www.diodes.com November 2015 © Diodes Incorporated DRTR5V0U4LP16 Suggested Pad Layout Please see AP02001 at http://www.diodes.com/datasheets/ap02001.pdf for the latest version. Y C Dimensions Z G X1 X2 Y C ADVANCED INFORMATION X2 G X1 Value (in mm) 1.3 0.175 0.50 0.525 0.30 0.50 Z IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDING TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2015, Diodes Incorporated www.diodes.com DRTR5V0U4LP16 Document number: DS37969 Rev. 1 - 2 4 of 4 www.diodes.com November 2015 © Diodes Incorporated