XP Power CLC125US24 125 watts clc sery Datasheet

ACDC
125 Watts
CLC Series
xppower.com
•
125 W Forcedcooled Rating
•
Low Profile 1.25”
•
Industry Standard 2” x 4” & 3” x 5” Package Sizes
•
12 V Fan Supply
•
Optional ORing Diode
•
<0.5 W No Load Input Power
•
3 Year Warranty
Specification
Input
General
• 85-264 VAC (120-370 VDC),
Derate output power linearly to 90% from
90 VAC to 85 VAC
Input Frequency
• 47-63 Hz
Input Current
• 2.3 A typical at 115 VAC, full load
1.1 A typical at 230 VAC, full load
Inrush Current
• 40 A max at 230 VAC, cold start 25 °C
Power Factor
• EN61000-3-2, class A
No Load Input Power • <0.5 W
Earth Leakage Current • 80/160 µA typical 115/230 VAC 50 Hz
300 µA at 264 VAC/60 Hz max.
Input Protection
• Internal T5 A/250 V fuse in line
Input Voltage
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
•
•
•
•
•
•
•
•
•
•
•
•
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient
•
•
•
•
•
12-48 VDC (see tables)
±10%
±1%
No minimum load required
1 s typical
50 ms
16 ms min at 230 VAC
±0.2% after 20 min warm up
±0.5% max
±1%
5% typical
4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
1% pk-pk V1, 20 MHz bandwidth
115-140% Vnom, recycle input to reset
110-150%
Continuous trip and restart (hiccup mode)
0.05%/˚C
Efficiency
Isolation
Switching Frequency
MTBF
• 88% typical
• 3000 VAC Input to Output, 1500 VAC
Input to Ground, 500 VDC Output to
Ground
• 65 KHz typical
• 1,245 KHrs to Telecordia SR-332
at 25 °C, GB
Environmental
Operating Temperature • 0 ˚C to +70 ˚C derate linearly from +50 ˚C
at 2.5%/˚C to 50% load at +70 ˚C.
Cooling
• Forced cooled, 10 CFM
Operating Humidity
• 95% RH, non-condensing
Storage Temperature • -40 ˚C to +85 ˚C
Operating Altitude
• 3000 m
Shock
• 30 g pk, half sine, 6 axes
Vibration
• 2 g rms, 5 Hz to 500 kHz, 3 axes
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level as below
Emissions
• EN55022 level B conducted
EN55022 level A radiated
Harmonic Currents
• EN61000-3-2, class A
Voltage Flicker
• EN61000-3-3
Radiated Immunity
• EN61000-4-3, level 3 Perf Criteria A
EFT/Burst
• EN61000-4-4, level 3 Perf Criteria A
Surge
• EN61000-4-5, installation class 3
Perf Criteria A
Conducted Immunity
• EN61000-4-6, level 3 Perf Criteria A
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals
• IEC60950-1 CB report, CSA 22.2
No. 60950-1, UL60950-1, TUV EN60950-1
Equipment Protection • Class I
Class
Output Power
Output Voltage V1
Output Current
Fan Supply V2
55 W
12.0 VDC
10.4 A
12 V / 0.5 A
CLC125US12
55 W
24.0 VDC
5.2 A
12 V / 0.5 A
CLC125US24
125 W
55 W
48.0 VDC
2.6 A
12 V / 0.5 A
CLC125US48
125 W
55 W
12.0 VDC
10.4 A
12 V / 0.5 A
CLC125US12-3x5(1)
125 W
55 W
24.0 VDC
5.2 A
12 V / 0.5 A
CLC125US24-3x5(1)
125 W
55 W
48.0 VDC
2.6 A
12 V / 0.5 A
CLC125US48-3x5(1)
125 W
55 W
12.0 VDC
10.4 A
12 V / 0.5 A
CLC125US12D-3x5(1)
125 W
55 W
24.0 VDC
5.2 A
12 V / 0.5 A
CLC125US24D-3x5(1)
125 W
55 W
48.0 VDC
2.6 A
12 V / 0.5 A
CLC125US48D-3x5(1)
10 CFM
Convection
125 W
125 W
Model Number
Notes
1. The 3 x 5 models share the same specification as the other models except the PCB size is increased to 3” x 5” from 2” x 4”. The ‘D’ models have an integral output
ORing diode.
Mechanical Details
CLC125
4.00 (101.6)
1.25 (31.8)
J1 mates with Molex housing
p/n 09-50-1031, and Molex
series 5194 crimp terminals
3.750 (95.25)
0.125 (3.18)
Voltage Adj.
Output Connector J2
Molex PN 09-65-2048
Pin 1
+V1
Pin 2
+V1
Pin 3
RTN
Pin 2
RTN
1.750 (44.45)
2.00 (50.8)
J1
J2
1.29
(32.7)
1.00 (25.4)
J2 mates with Molex housing
p/n 09-50-1041 and Molex
series 5194 crimp terminals
Fan Supply Connector J3
Molex PN 22-04-1021
Pin 1
Fan+
Pin 2
Fan-
0.45
J3 (11.4)
0.125 (3.18)
0.20 (5.1)
0.29 (7.3)
0.20 (5.1)
0.25 Faston
Ground Tab
0.14 (3.5)
SMD Component Height
4 X ø.156 (3.96) Mounting Holes
ø.312 (7.92) Clearance top and bottom
CLC125 3x5 & CLC125 D 3x5
5.00 (127.0)
0.225 (5.72)
4.55 (115.57)
3.0 (76.2)
1.20
(30.5)
Voltage Adj.
0.20 (5.10)
J2
1.79
(45.4)
J3
0.95
(24.1)
0.225 (5.72)
0.25 Faston
Ground Tab
4 X ø.156 (3.96) Mounting Holes
ø.312 (7.92) Clearance top and bottom
J3 mates with Molex housing
p/n 22-01-1024 and Molex
series 5103 crimp terminals
Input Connector J1
Molex PN 09-65-2038
Pin 1
Line
Pin 2
Neutral
J1 mates with Molex housing
p/n 09-50-1031, and Molex
series 5194 crimp terminals
Output Connector J2
Molex PN 09-65-2048
Pin 1
+V1
Pin 2
+V1
Pin 3
RTN
Pin 2
RTN
2.55 (64.77)
1.52 (38.6)
Input Connector J1
Molex PN 09-65-2038
Pin 1
Line
Pin 2
Neutral
0.20 (5.1)
0.13 (3.2)
0.14 (3.5)
SMD Component Height
J2 mates with Molex housing
p/n 09-50-1041 and Molex
series 5194 crimp terminals
Fan Supply Connector J3
Molex PN 22-04-1021
Pin 1
Fan+
Pin 2
FanJ3 mates with Molex housing
p/n 22-01-1024 and Molex
series 5103 crimp terminals
Notes
1. All dimensions in inches (mm).
2. Weight 0.386 lbs (175 g)
3. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
21-Jan-11