XP Power ECE60US36 Ac-dc power supply Datasheet

ECE60 Series
AC-DC Power Supplies
60 Watts
• Ultra Compact Size
• Single Outputs from 3.3 to 48 V
• Encapsulated
• PCB & Chassis Mount Versions
• <0.3 W No Load Input Power
• -40 to +70 °C Operation
• Peak Load Capability
• 3 Year Warranty
Dimensions:
The ECE60 series of compact encapsulated AC-DC power modules are available in both PCB &
chassis mount versions offering exceptional power density of >10W/in3. Output voltages are
available from 3.3 – 48 VDC and these “green power” modules offer high active mode efficiency
and low no load power consumption. They also provide a peak load capability up to 130% of
nominal power for up to 30s and a wide operating temperature range from -40 to +70°C.
ECE60:
3.60 x 1.50 x 1.10” (91.4 x 38.1 x 28.0 mm)
ECE60-S:
4.45 x 1.57 x 1.12” (113.0 x 40.0 x 28.5 mm)
Models & Ratings
Output Power
Output Current
Output Voltage
Nominal
Peak
(1)
Efficiency
(4)
Model Number
33 W
3.3 V
10.00 A
13.00 A
79%
50 W
5.0 V
10.00 A
13.00 A
83%
ECE60US05
60 W
9.0 V
6.67 A
8.67 A
87%
ECE60US09
60 W
12.0 V
5.00 A
6.50 A
87%
ECE60US12
60 W
15.0 V
4.00 A
5.20 A
88%
ECE60US15
60 W
24.0 V
2.50 A
3.25 A
89%
ECE60US24
60 W
36.0 V
1.67 A
2.17 A
88%
ECE60US36
60 W
48.0 V
1.25 A
1.63 A
86%
ECE60US48
(2,3)
ECE60US03
Notes
1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal power.
2. Add suffix -S to model number to denote chassis mount with screw terminal type, e.g. ECE60US12-S.
3. A screw terminal version (-S) is available with DIN Clip attached. Add suffix ‘D’, e.g. ECE60US24-SD. DIN Rail mounting clip is available as a separate item, order
code ECE60 DIN CLIP.
4. Average of efficiencies measured at 25%, 50%, 75% & 100% load with 230 VAC input.
Summary
Characteristic
Input Range
Minimum
Maximum
Units
85
264
VAC
120
370
VDC
No Load Input Power
1
Efficiency
79
Operating Temperature
-40
Typical
Notes & Conditions
Derate load from 100% at 90 VAC to 90% at 85 VAC
<0.3
W
<0.5
W
3.3-9 V & 48 V versions
89
%
See note 4 above
+70
°C
Some specification parameters may not met below -25 °C.
Derate linearly from 100% load at +50 °C to 50% load at
70 °C.
87
EMC
EN55022 Level B Conducted & Radiated, EN61000-4, EN61000-3
Safety Approvals
EN60950-1, UL60950-1, CSA22.2 No. 234 per cUL
www.xppower.com
12-36 V versions
ECE60 Series
AC-DC Power Supplies
Input
Characteristic
Input Voltage - Operating
Input Frequency
Minimum
Maximum
Units
85
Typical
264
VAC
120
370
VDC
47
63
Hz
Power Factor
Derate load from 100% at 90 VAC to 90% at 85 VAC
EN61000-3-2 class A compliant
Input Current
0.6
No Load Input Power
Inrush Current
A rms
At 230 VAC
0.3
W
12-36 V versions
0.5
W
3.3-9 V & 48 V versions
A
115/230 VAC cold start at 25 °C
20/40
Earth Leakage Current
Input Protection
Notes & Conditions
Class II construction no earth
Internal T1 A/250 VAC fuse
Output
Characteristic
Minimum
Output Voltage
3.3
Typical
Initial Set Accuracy
Minimum Load
Maximum
Units
Notes & Conditions
48
VDC
See Models and Ratings table
±1
%
0
A
Start Up Delay
2
s
Start Up Rise Time
16
ms
Hold Up Time
18
ms
Line Regulation
Load Regulation
Transient Response
Ripple & Noise
Overvoltage Protection
Overload Protection
At full load and 115 VAC
±0.5
%
±2
%
±1
%
All other models
4
%
Recovery within 1% in less than 500 µs
for a 25% load change
60
mV pk-pk
3.3-5 V versions, 20 MHz bandwidth
75
mV pk-pk
3.3-5 V ‘-S’ versions, 20 MHz bandwidth,
0.1 µF capacitor at output terminals
ECE60US03/05-S
1
% pk-pk
20 MHz bandwidth all other models
216
% Vnom
ECE60US03 models
115
140
% Vnom
All other models
110
180
%
0.05
%/˚C
195
Short Circuit Protection
Trip & restart (hiccup mode)
Temperature Coefficient
General
Characteristic
Minimum
Typical
Maximum
Units
Efficiency
79
87
89
%
Isolation
3000
VAC
100
Switching Frequency
Power Density
Weight
Input to Output
kHz
10.1
Mean Time Between Failure
Notes & Conditions
See Models & Ratings table
W/in3
>300
kHrs
MIL-HDBK-217F, +25 °C GB
0.42 (191)
lb (g)
ECE60
0.44 (200)
ECE60-S
Environmental
Characteristic
Minimum
Typical
Maximum
Units
Operating Temperature
-25
+70
°C
Storage Temperature
-40
+85
°C
95
%RH
3048
m
Cooling
Humidity
Operating Altitude
Vibration
Notes & Conditions
Some specification parameters may not met below -25 °C.
Derate linearly from 100% load at +50 °C to 50% load at 70 °C.
Convection-cooled
Non-condensing
2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins each cycle
www.xppower.com
2
ECE60 Series
AC-DC Power Supplies
EMC: Emissions
Phenomenon
Test Level
Standard
Conducted
EN55022
Class B
Radiated
EN55022
Class B
Harmonic Current
EN61000-3-2
Voltage Flicker
EN61000-3-3
Criteria
Notes & Conditions
Class A
EMC: Immunity
Phenomenon
Test Level
Criteria
EN61000-4-2
3
A
Standard
ESD
Radiated
EN61000-4-3
10 V/m 80% mod
A
EFT
EN61000-4-4
3
A
Surges
EN61000-4-5
Installation Class 3
A
Conducted
EN61000-4-6
3
A
Dips and Interruptions
EN61000-4-11
DIP: 100% 10 ms
DIP: 30% 500 ms
INT: 100% 5000 ms
A
A
B
Notes & Conditions
Safety Approvals
Safety Agency
Safety Standard
UL
UL60950-1, CSA 22.2 No.234 per cUL
Notes & Conditions
TUV
EN60950-1
CB
IEC60950-1
Mechanical Details
ECE60
0.139 (3.54)
3.60 (91.4)
ACL
1.50
(38.1)
1.18
(30.0)
ECE60 Screw Terminal (-S)
0.50
(12.7)
0.18 (4.5)
4x ø0.14
(4x ø3.5)
0.44
(11.2)
+Vo
TOP VIEW
4.09 (104.0)
ACN
-Vo
1.57
(40.0)
0.159
(4.05)
TOP VIEW
ACL
-Vo
0.84
(21.3)
1.20
+Vo
(30.5)
ACN
0.14
(3.55)
3.50 (89.7)
3.32 (84.3)
0.54 (13.8)
0.19
(4.8)
1º
1.12
(28.5)
1.10
(28.0)
4x ø 0.06 (ø1.5)
0.24
(6.2)
0.4 (10.2)
0.10
(2.5)
4.45 (113.0)
Optional
DIN clip
Notes
1. All dimensions in inches (mm).
2. Weight: ECE60: 0.42 lbs (191 g)
ECE60-S: 0.44 lbs (200 g)
3. Tolerances: x.xx = ± 0.02 (x.x = ± 0.5), x.xxx = ± 0.01 (x.xx = ± 0.25)
3
www.xppower.com
1-Dec-15