ice GT03-111-069-B Gate drive transformer Datasheet

GT03 Series
Gate Drive Transformer
Features
Applications
• Meets medical VDE creepage/clearance
• Gate Drive Transformer
• Optimized for frequencies from
100 kHz to 350 kHz
• AC/DC and DC/DC
Converters
• Signal Transformer Across
Isolation Barrier
Packaging: Reel diameter: 13”, Reel width: 24mm, Pieces/reel: 500
8
Schematic
Recommended PCB
layout
Mechanical
5
2.54
5
6.8
max
GT03-XXX-XXX-X
YYWW
8
1
6
5
Gate
3
16.9
1.6
16.0 ref.
color dot
for pin 1
7
Drive
4
6
7
Gate
8
4
1
units: mm
10.7 max
2
3
4
1.2
Electrical Specifications
Turns Ratio
Drive:Gate
Drive Ind.1
(µH, min.)
DCR
(mΩ, max.)
Lkg. Ind.
(nH, max.)
E-T Prod5
(V-µs)
Hi-Pot
GT03-111-034-A
1:1:1
882
550:550
300
34.6
1500 Vdc
GT03-111-052-A
1:1:1
1985
850:850
370
51.9
1500 Vdc
GT03-111-069-A
1:1:1
2000
1300:1300
300
69
1500 Vdc
GT03-111-110-A
1:1:1
5100
1900:1900
550
110
1500 Vdc
GT03-122-037-A
1:2.5:2.5
162
265:590
180
37.1
1500 Vdc
GT03-122-055-A
1:2.5:2.5
365
400:900
300
55.6
1500 Vdc
GT03-111-034-B
1:1:1
882
600:600
360
34.6
3750 Vac
GT03-111-069-B
1:1:1
2000
1430:1300
470
69
3750 Vac
GT03-122-037-B
1:2.5:2.5
162
280:590
240
37.1
3750 Vac
GT03-111-034-C
1:1:1
882
600:600
360
34.6
3750 Vac
GT03-111-069-C
1:1:1
2000
1430:1300
470
69
3750 Vac
GT03-122-037-C
1:2.5:2.5
162
280:590
240
37.1
3750 Vac
Part
Number
1. Tested at 100kHz, 0.1Vrms.
2. Electrical specifications at
25°C.
3. Operating range: -40° C
to +130° C.
4. Meets UL 94V-0.
5. E-T product rating is for
secondary (gate) windings
and is based upon flux
density of 2200 Gauss at
25°C in a bipolar drive
application.
GT03-XXX-XXX-A: 0mm creepage/clearance
B: 3mm creepage/clearance
C: 8mm creepage/clearance
Specifications subject to change without notice.
800.729.2099 tel
www.icecomponents.com
(09/10) GT03-1