COST SAVING SUBMINIATURE PC BOARD RELAYS 14.0 .551 14.2 .559 26.5 1.043 26.3 1.035 16.9 .665 17.7 .697 HA-RELAYS FEATURES • Compact construction • Sensitive - very low operating power • Soldering flux inflow prevented by molded construction • Contact capacity - 3 A 250 V AC, 30 V DC • Simple mechanism for stable quality - only 9 pieceparts • Amber sealed types available HAE Amber Relays mm inch SPECIFICATIONS HA1 Standard type Contacts HA1E Amber sealed type Contacts Arrangement 1 Form C Contact material Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Max. switching power Rating (resistive Max. switching voltage load) Max. switching current Mechanical Expected life (min. Electrical 3 A 250 V AC operations) (resistive) 3 A 30 V DC Silver-nickel 50 mΩ 750 VA, 90 W 250 V AC, 30 V DC 3A 107 105 5×105 Coil (AC) 0.58 VA, (DC) 230 mW (AC) 0.9 VA, (DC) 360 mW Characteristics Operate time*3 (at nominal voltage) (at 20°C) Release time (without diode)*3 (at nominal voltage)(at 20°C) Temperature rise (at 20°C) Functional Destructive Functional Vibration resistance Destructive 20 cpm Min. 100 MΩ at 500 V DC 750 Vrms for 1 min. 1,500 Vrms for 1 min. Approx. 6 ms (AC), Approx. 5 ms (DC) Approx. 6 ms (AC), Approx. 3 ms (DC) Max. (AC) 60°C, (DC) 40°C with nominal coil voltage and at 3A switching current 98 m/s2 {10G} 980 m/s2 {100G} 10 to 55Hz at double amplitude of 1mm 10 to 55Hz at switching of 2mm Ambient temp. –40°C to +50°C –40°F to +122°F Humidity 5 to 85%R.H. Approx. 15 g .53 oz * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Intial breakdown voltage" section *2 Detection current: 10 mA 208 50 mΩ 500 VA, 90 W 250 V AC, 30 V DC 2 A AC, 3A DC 107 105 2×105 Minimum operating power Nominal operating power (AC) 0.58 VA, (DC) 230 mW (AC) 0.9 VA, (DC) 360 mW Characteristics Maximum operating speed Initial insulation resistance*1 (at 25°C, 50% R.H.) Initial Between open contacts breakdown 2 Between contacts and coil voltage* Conditions for operation, transport and storage*4 (Not freezing and condensing at low temperature) Unit weight Remarks 1 Form C Gold-clad over silver-nickel Coil Minimum operating power Nominal operating power Shock resistance Arrangement Contact material Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Max. switching power Rating (resistive Max. switching voltage load) Max. switching current Mechanical Expected life (min. Electrical 2 A 250 V AC operations) (resistive) 3 A 30 V DC Maximum operating speed Initial insulation resistance*1 (at 25°C, 50% R.H.) Initial Between open contacts breakdown 2 Between contacts and coil voltage* Operate time*3 (at nominal voltage) (at 20°C) Release time (without diode)*3 (at nominal voltage)(at 20°C) Temperature rise (at 50°C) Shock resistance Functional Destructive Functional Vibration resistance Destructive Conditions for operation, transport and storage*4 (Not freezing and condensing at low temperature) Unit weight 20 cpm Min. 100 MΩ at 500 V DC 750 Vrms for 1 min. 1,500 Vrms for 1 min. Approx. 6 ms (AC), Approx. 5 ms (DC) Approx. 6 ms (AC), Approx. 3 ms (DC) Max. (AC) 60°C, (DC) 40°C with nominal coil voltage and at 3A switching current 98 m/s2 {10G} 980 m/s2 {100G} 10 to 55Hz at double amplitude of 1mm 10 to 55Hz at double amplitude of 2mm Ambient temp. –40°C to +50°C –40°F to +122°F Humidity 5 to 85%R.H. Approx. 15 g.53 oz *3 Excluding contact bounce time *4 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61). HA TYPICAL APPLICATIONS ORDERING INFORMATION Ex. Office machines, electrical home appliances, load management equipment. HA 1 E DC6V Contact arrangement Type classification Coil voltage 1: 1 Form C Nil: Dust cover type E: Amber sealed type DC 5, 6, 9, 12, 24 V AC 6, 12, 24, 48, 115V Notes: 1. For UL/CSA recognized types, add suffix UL/CSA. (Notes) 2. Standard packing Carton: 100 pcs., Case: 500 pcs. or 2,000 pcs. TYPES AND COIL DATA (at 20°C 68°F) Part No. Nominal voltage Pick-up voltage, (max.) Drop-out voltage, (min.) * Nominal operating current, mA Nominal operating power Coil resistance, Ω (±10%) Maximum allowable voltage 6 V AC 4.8 V AC 1.2 V AC 150 0.9 VA — 6.6 V AC 12 V AC 9.6 V AC 2.4 V AC 76 0.9 VA — 13.2 V AC 24 V AC 19.2 V AC 4.8 V AC 37 0.9 VA — 26.4 V AC 48 V AC 38.4 V AC 9.6 V AC 19 0.9 VA — 52.8 V AC 115 V AC 92.0 V AC 23.0 V AC 8 0.9 VA — 126.5 V AC 5 V DC 4.0 V DC 0.5 V DC 72 360 mW 69 6.0 V DC 6 V DC 4.8 V DC 0.6 V DC 60 360 mW 100 7.2 V DC 9 V DC 7.2 V DC 0.9 V DC 40 360 mW 225 10.8 V DC 12 V DC 9.6 V DC 1.2 V DC 30 360 mW 400 14.4 V DC 24 V DC 19.2 V DC 2.4 V DC 15 360 mW 1,600 28.8 V DC HA1-AC6V HA1E-AC6V HA1-AC12V HA1E-AC12V HA1-AC24V HA1E-AC24V HA1-AC48V HA1E-AC48V HA1-AC115V HA1E-AC115V HA1-DC5V HA1E-DC5V HA1-DC6V HA1E-DC6V HA1-DC9V HA1E-DC9V HA1-DC12V HA1E-DC12V HA1-DC24V HA1E-DC24V Note: The range of coil current — AC type: ±15% at 60 Hz, DC type: ±10% at 20°C 68°F coil temperature. DIMENSIONS mm inch PC board pattern (Copper-side view) HA1 HA1E HA1 1 Relay outline 16.4 .646 5-1.2 dia. 5-.047 dia. 1.34 .053 17.7 .697 0.5 .020 4 .157 0.6 dia. .024 dia. 3.2 .126 26.3 1.035 9.1 .358 4 .157 0.8 .031 1.3 .051 0.6 dia. .024 dia. 6.5 .256 11.6 .457 14 .551 0.6 dia. .024 dia. 19.1 .752 24.2 .953 General tolerance: ±0.5 ±.020 0.9 dia. .035 dia. 9.0 .354 4.8 .189 17 .669 HA1E 26.6 1.047 6.5 .256 11.5 .453 14.2 .559 3.9 .154 0.8 .031 1.5 .059 0.5 4.8 .020 .189 0.6 dia. .024 dia. General tolerance: ±0.5 ±.004 4 3 6.5 .256 14.0 .551 2.54×2 .100×2 2.54×7 .100×7 26.3 1.035 Relay outline 6.5 .256 14.2 .559 5-1.2 dia. 5-.047 dia. 1.5 .059 0.9 dia. .035 dia. 19.2 .756 24.3 .957 2 5 2.54×2 .100×2 2.54×7 .100×7 26.5 1.043 Tolerance: ±0.1 ±.004 Schematic (Bottom view) 1 2 5 4 3 209 HA REFERENCE DATA 1.-(1) Coil temperature rise (AC PC board type) 1.-(2) Coil temperature rise (DC PC board type) Point measured: Inside the coil 50 50 Hz 3 A 60 50 Hz deactivated 50 60 Hz 3 A 40 60 Hz deactivated Temperature rise, °C Temperature rise, °C 70 30 0 40 Contact activated: 3 A 30 Contact activated: 0 A 20 10 80 0 100 110 Coil applied voltage, %V 80 100 120 150 Coil applied voltage, %V Operate and release time Sample: HA1-DC12V Sample: HA1-AC115V Operate time Release time Operate time Release time 20 15 Max. x 10 Min. Max. x Min. 5 0 80 100 120 Coil applied voltage, %V Time, ms Time, ms 20 Max. x 15 Min. 10 Max. x Min. 5 0 80 100 120 Coil applied voltage, %V For Cautions for Use, see Relay Technical Information (Page 48 to 76). 210 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog