DB Lectro NG5NADC5V Switching capacity up to 5a. / low coil power consumption 0.2w. Datasheet

N G 5 N
20.5×7.2×15.3
Features
Small size, light weight.
Switching capacity up to 5A.
Low coil power consumption 0.2W.
Suitable for household electrical appliance, automation system, electronic equipment, instrument, meter,
telecommunication facilities and remote control facilities.
Ordering Information
NG5N A DC12V
1
2
3
1 Part number:NG5N
2 Contact Arrangement:A:1A
3 Coil rated Voltage(V):DC:3,5,6,9,12,18,24
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
life
Mechanical
1ASPSTNO
Silver Alloy
5A/30VDC,250VAC
150W 1250VA
30VDC 250VAC
አ100m
105
107
min Switching load:10mA/5V
Max. Switching Current:5A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
CAUTION:
Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not
recommended for subsequent use in low level applications.
Coil Parameter
Dash
Numbers
Coil voltage
VDC
Rated
Coil
resistance
±10%
Pickup
voltage
VDC(max)
(75%of rated
voltage )
release voltage
VDC(min)
(10% of rated
voltage)
Max.
003-200
3
3.9
45
2.25
0.3
005-200
5
6.5
125
3.75
0.5
006-200
6
7.8
180
4.50
0.6
009-200
9
11.7
405
6.75
0.9
012-200
12
15.6
720
9.00
1.2
018-200
18
23.4
1620
13.5
1.8
024-200
24
31.2
2880
18.0
2.4
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
0.2
10
4
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
41
www.dblectro.com
NG5N
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
1000M
min (at 500VDC)
Item 7 of IEC255-5
50Hz 750V
50Hz 4000V surge voltage:7kV
Item 6 of IEC255-5
Item 6 and 8 of IEC255-5
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
Functional:100m/s2 11ms Survival:1000m/s2 6ms
10~50Hz Functional & Survival double amplitude 1.5mm
5N
235’x2’ 3x0.5s
-30~70’
20%~85% (at 40’)
4g
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.
Dimensions (Unit: mm)
Mounting (Bottom views)
Dimensions
mm
>àçÇá
0.27
0.52
0.8
1.05
1.1
1.2
3.4
4.7
7
7.2
11.5
15.3
20.5
0.011
0.020
0.031
0.041
0.043
0.047
0.134
0.185
0.275
0.283
0.453
0.602
0.807
Wiring diagram
(Bottom views)
NOTES 1).Dimensions are in millimeter.
2).Inch equivalents are given for general information only.
www.dblectro.com
Similar pages