DB Lectro HG4508/012-2Z2A Automotive subminiature pcb twin relay Datasheet

HG4508
Automotive Subminiature PCB Twin Relay
FEATURES
Two independent relay installed in one package
Miniaturized structure, light weight
Improved contact capacity
Big gap type available for heavy motor load switching
TYPICAL AUTOMOTIVE APPLICATIONS
Power antenna
Tilt lock wheel
Power window
Automatic door lock
Interval wiper
Automatic seat adjustment
Slide roof control
CONTACT DATA
Mechanical
2 Form C (2Z)
60A
20A
AgNi0.15, AgSnOInO
16VDC
35A, 10 min; 25A, 1 hr
0.1A, 5VDC
107 ops.
Electrical
105 ops. see Note 3
Form
Make
Break
Max. Switching Current
Material
Max. Switching Voltage
Max. Continuous Current
Min. Load
Service Life
COIL DATA
Type
Coil Voltage
Code
Nominal
Voltage
(VDC)
Resistance
(Ω) ±10%
Must Operate
Voltage max.
(VDC)
Must Release
Voltage min.
(VDC)
006
009
012
024
006
009
012
024
6
9
12
24
6
9
12
24
60
135
240
960
45
100
180
720
3.6
5.4
7.3
14.4
3.6
5.4
7.3
14.4
0.6
0.9
1.2
2.4
0.6
0.9
1.2
2.4
Standard
0.6W
Big Gap
0.8W
CHARACTERISTICS
Operate Time
Release Time
Insulation Resistance
Dielectric Strength
Shock Resistance
Viberation Resistance
Drop Resistance
Power Consumption
Ambient Temperature
Weight
10 ms. typical
5 ms. typical
100 MΩ, at 500 VDC, 50%RH
500 Vrms, 1 min.
10 g, 11ms.
DA 1.5 mm, 10 - 55 Hz
1 M hight drop on concrete
Standard: 0.6W; Big Gap: 0.8 W
-30 C to 85 C operating; -40 C to 100 C storage
13 g, approx.
ORDERING DESIGNATION
Example:
HG4508 /
Model
Coil Voltage Code
Contact Form
2Z: 2 Form C
Version
1: Sealed; 2: Dust Cover
Contact Material
Nil: AgNi10; A: AgNi0.15; C: AgCdO; S: AgSnOInO
Contact gap
Nil: Standard; G: Big Gap
012 -
2Z
1
A
G
HG4508
1/2
HG4508
REFERENCE CURVE
Power Load Limit
OVERALL DIMENSIONS, MOUNTING HOLES AND WIRING DIAGRAM (mm)
Overall Dimensions
Mounting Holes (Bottom View)
Wiring Diagram (Bottom View)
NOTES
1.
2.
3.
4.
5.
All parameters, unless otherwise specified, are measured at ambient temperature 23ºC.
Maximum make current refers to inrush current of motor load.
Elecreical life obtained at motor load of locked rotor at 20A, 14VDC with operating frequency of 1 ops/sec.
Custom-made services available with operational quantity. Please let us know your special requirements.
Specifications subject to change without prior notice.
DB LECTRO INC. 3600 boul. Matte suite I Brossard Qc J4Y-2Z2
TEL:(450)-444-1424 FAX: (450)-444-4714
HG4508