VIMARLOW NL3040 Thermoelectric module Datasheet

Technical Data Sheet for NL3040
Thermoelectric Module
NOMINAL PERFORMANCE IN NITROGEN
Hot Side Temperature (°C)
Δ Tmax (°C):
Qmax (watts):
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
PRODUCT FEATURES
•
•
•
•
27
98
5.6
4.5
7.3
1.57
50
111
6.25
4.5
8.2
--
ORDERING OPTIONS
RoHS EU Compliant
Pretinned metallized ceramic surface(s) with 117°C solder.
Thermistor mounted on edge of cold side ceramic.
(Calibration available.)
Elevated temperature burn-in with test data provided.
Model Number
NL3040-01
NL3040-02
NL3040-03
Description
Both Surfaces are Metallized
Hot Side Exterior is Metallized
No Metallization
OPERATION CAUTIONS
INSTALLATION
For maximum reliability, storage and operation below 85°C in a
non-condensing environment is recommended. To minimize
thermal stress, use linear/proportional temperature control or
a similar method rather than an ON/OFF method.
Recommended mounting methods: Bonding with thermal
epoxy or soldering with metallized ceramics. For additional
information, please refer to our TEM Installation Guide.
II-VI Marlow – Dallas, TX USA
214-340-4900
877-627-5691
[email protected]
Marlow Industries Europe
GmbH - Germany
+49 (0) 6150 5439 - 403
[email protected]
II-VI Japan Inc.
81 43 297 2693 (tel)
[email protected]
www.ii-vi.co.jp
MI Form 005-0808 Rev. B
www.marlow.com
II-VI Singapore Pte., Ltd.
(65) 6481 8215 (tel)
[email protected]
Marlow Industries China, II-VI
Technologies Beijing
86-10-643 98226
[email protected]
DOC # 102-0306 REV J - PAGE 1 OF 2
Hot Side Temperature 27°C
120.0
HEAT
LOAD
(WATTS)
40.0
20.0
T (C)
60.0
120.0
80.0
60.0
40.0
20.0
0.0
0.0
8.0
8.0
6.0
4.0
2.0
0.0
0.0
Q=0
T=0
1.0
2.0
3.0
4.0
CURRENT (AMPS)
0.00
1.00
2.00
3.00
4.00
5.00
6.00
100.0
0.00
1.00
2.00
3.00
4.00
5.00
80.0
HEAT
LOAD
(WATTS)
Hot Side Temperature 50°C
VOLTAGE (VDC)
T (C)
100.0
VOLTAGE (VDC)
TYPICAL PERFORMANCE CURVES
ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN
6.0
4.0
Q=0
T=0
2.0
0.0
0.0
5.0
1.0
2.0
3.0
4.0
CURRENT (AMPS)
5.0
MECHANICAL CHARACTERISTICS
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, contact one of our Applications Engineers at 877-627-5691.
POSITIVE LEAD
.855
[21.72]
.339
[8.61]
Beryllium Oxide Handling
Precautions
LEADS: 22 AWG (0.64) BUS
SOLID TINNED COPPER
NEGATIVE LEAD
.511
[12.98]
Beryllium oxide can be toxic only when
dust, mist, or fumes containing particles
small enough to enter the lungs are
inhaled. For the user, precautions required
are to avoid grinding, machining or
pulverizing the material by mechanical,
thermal, or chemical processing.
marlow industries, inc.
2.00±.25
[50.80±6.35]
1.113
[28.27]
R
COLD SIDE
.009 [0.23] A
.001 [0.03]
.425±.015
[10.80±0.38]
.003 [0.08]
A
Ceramic Material: Beryllia (BC)
Millimeters are in [ ]
All units are in inches and [ ] are in millimeters unless otherwise stated.
For customer support or general questions please contact a local office or visit our website at www.marlow.com.
Marlow reserves the right to make product changes without notice.
MI Form 005-0808 Rev. B
www.marlow.com
DOC # 102-0306 REV J - PAGE 2 OF 2