MCC 1N4001GP THRU 1N4007GP omponents 21201 Itasca Street Chatsworth !"# $ % !"# Features • • • • 1 Amp Glass PassivatedRectifier 50 - 1000 Volts Glass Passivated Junction Low Current Leakage Metalurgically Bonded Construction Low Cost Maximum Ratings • • • DO-41 Operating Temperature: -55°C to +150°C Storage Temperature: -55°C to +150°C Maximum Thermal Resistance; 20 °C/W Junction To Lead MCC Catalog Number Device Marking 1N4001GP 1N4002GP 1N4003GP 1N4004GP 1N4005GP 1N4006GP 1N4007GP --------------- Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V Maximum RMS Voltage Maximum DC Blocking Voltage 35V 70V 140V 280V 420V 560V 700V 50V 100V 200V 400V 600V 800V 1000V D A Cathode Mark B D C Electrical Characteristics @ 25°C Unless Otherwise Specified Average Forward IF(AV) 1.0A TA = 75°C Current Peak Forward Surge IFSM 30A 8.3ms, half sine Current Maximum 1.1V IFM = 1.0A; Instantaneous VF Forward Voltage TJ = 25°C* Maximum DC Reverse Current At IR 5.0µA TJ = 25°C Rated DC Blocking 50µA TJ = 125°C Voltage Typical Junction CJ 15pF Measured at Capacitance 1.0MHz, VR=4.0V *Pulse test: Pulse width 300 µsec, Duty cycle 2% DIMENSIONS DIM A B C D INCHES MIN .166 .080 .028 1.000 www.mccsemi.com MAX .205 .107 .034 --- MM MIN 4.10 2.00 .70 25.40 MAX 5.20 2.70 .90 --- NOTE MCC 1N4001GP thru 1N4007GP Figure 1 Typical Forward Characteristics 20 Figure 2 Forward Derating Curve 10 1.2 6 4 1.0 2 Amps .8 1 .6 .6 Amps .4 .4 .2 25°C .2 .1 Single Phase, Half Wave 60Hz Resistive or Inductive Load .06 0 .04 0 50 75 100 125 150 175 °C .02 .01 .4 .6 .8 1.0 1.2 Average Forward Rectified Current - Amperesversus Ambient Temperature - °C 1.4 Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Figure 3 Junction Capacitance 100 60 40 20 pF TJ=25°C 10 6 4 2 1 .1 .2 .4 1 Volts 2 4 10 20 40 100 200 400 Junction Capacitance - pFversus Reverse Voltage - Volts www.mccsemi.com 1000 MCC 1N4001GP thru 1N4007GP Figure 4 Typical Reverse Characteristics Figure 5 Peak Forward Surge Current 100 60 60 40 50 20 40 10 30 6 Amps 4 T =100°C A 20 10 5 0 2 µAmps 1 .6 1 2 4 6 8 10 40 60 80 100 Cycles .4 Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles .2 .1 20 TA=25°C .06 .04 .02 .01 20 40 60 80 100 120 140 Volts Instantaneous Reverse Leakage Current - MicroAmperesversus Percent Of Rated Peak Reverse Voltage - Volts www.mccsemi.com