AD AD606JR-REEL 50 mhz, 80 db demodulating logarithmic amplifier with limiter output Datasheet

a
50 MHz, 80 dB Demodulating
Logarithmic Amplifier with Limiter Output
AD606
a loadable output voltage of +0.1 V dc to +4 V dc. The logarithmic scaling is such that the output is +0.5 V for a sinusoidal
input of –75 dBm and +3.5 V at an input of +5 dBm; over this
range the logarithmic linearity is typically within ± 0.4 dB. All
scaling parameters are proportional to the supply voltage.
FEATURES
Logarithmic Amplifier Performance
–75 dBm to +5 dBm Dynamic Range
≤1.5 nV/√Hz Input Noise
Usable to >50 MHz
37.5 mV/dB Voltage Output
On-Chip Low-Pass Output Filter
Limiter Performance
ⴞ1 dB Output Flatness over 80 dB Range
ⴞ3ⴗ Phase Stability at 10.7 MHz over 80 dB Range
Adjustable Output Amplitude
Low Power
+5 V Single Supply Operation
65 mW Typical Power Consumption
CMOS-Compatible Power-Down to 325 ␮W typ
<5 ␮s Enable/Disable Time
The AD606 can operate above and below these limits, with
reduced linearity, to provide as much as 90 dB of conversion
range. A second low-pass filter automatically nulls the input
offset of the first stage down to the submicrovolt level. Adding
external capacitors to both filters allows operation at input frequencies as low as a few hertz.
The AD606’s limiter output provides a hard-limited signal
output as a differential current of ± 1.2 mA from open-collector
outputs. In a typical application, both of these outputs are
loaded by 200 Ω resistors to provide a voltage gain of more than
90 dB from the input. Transition times are 1.5 ns, and the
phase is stable to within ± 3° at 10.7 MHz for signals from
–75 dBm to +5 dBm.
APPLICATIONS
Ultrasound and Sonar Processing
Phase-Stable Limiting Amplifier to 100 MHz
Received Signal Strength Indicator (RSSI)
Wide Range Signal and Power Measurement
The logarithmic amplifier operates from a single +5 V supply
and typically consumes 65 mW. It is enabled by a CMOS logic
level voltage input, with a response time of <5 µs. When disabled, the standby power is reduced to <1 mW within 5 µs.
PRODUCT DESCRIPTION
The AD606J is specified for the commercial temperature range
of 0°C to +70°C and is available in 16-lead plastic DIPs or
SOICs. Consult the factory for other packages and temperature
ranges.
The AD606 is a complete, monolithic logarithmic amplifier
using a 9-stage “successive-detection” technique. It provides
both logarithmic and limited outputs. The logarithmic output is
from a three-pole post-demodulation low-pass filter and provides
FUNCTIONAL BLOCK DIAGRAM
INHI
COMM
PRUP
VPOS
FIL1
FIL2
LADJ
LMHI
16
15
14
13
12
11
10
9
REFERENCE
AND POWER-UP
30pF
360kV
X1
30kV
360kV
30pF
30kV
OFFSET-NULL
LOW-PASS FILTER
1.5kV
250V
9.375kV
12mA/dB
HIGH-END
DETECTORS
1.5kV
FINAL
LIMITER
MAIN SIGNAL PATH
11.15dB/STAGE
ONE-POLE
FILTER
AD606
2pF
9.375kV
TWO-POLE
SALLEN-KEY
FILTER
X2
2pF
2mA/dB
1
2
3
4
5
6
7
8
INLO
COMM
ISUM
ILOG
BFIN
VLOG
OPCM
LMLO
REV. B
Information furnished by Analog Devices is believed to be accurate and
reliable. However, no responsibility is assumed by Analog Devices for its
use, nor for any infringements of patents or other rights of third parties
which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Analog Devices.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781/329-4700
World Wide Web Site: http://www.analog.com
Fax: 781/326-8703
© Analog Devices, Inc., 1999
AD606–SPECIFICATIONS (@ T = +25ⴗC and supply = +5 V unless otherwise noted; dBm assumes 50 ⍀)
A
Model
Parameter
SIGNAL INPUT
Log Amp fMAX
Limiter fMAX
Dynamic Range
Input Resistance
Input Capacitance
SIGNAL OUTPUT
Limiter Flatness
Output Current
Phase Variation with Input Level
LOG (RSSI) OUTPUT
Nominal Slope
Slope Accuracy
Intercept
Logarithmic Conformance
Nominal Output
Accuracy over Temperature
Video Response Time
POWER-DOWN INTERFACE
Power-Up Response Time
Input Bias Current
POWER SUPPLY
Operating Range
Powered-Up Current
Powered-Down Current
Conditions
Min
AC Coupled; Sinusoidal Input
AC Coupled; Sinusoidal Input
Differential Input
Differential Input
500
–75 dBm to +5 dBm Input Signal at 10.7 MHz
With Pin 9 to VPOS via a 200 Ω Resistor
and Pin 8 to VPOS via a 200 Ω Resistor
At Pins 8 or 9, Proportional to VPOS, LADJ Grounded
LADJ Open Circuited
–75 dBm to +5 dBm Input Signal at 10.7 MHz
–1.5
At 10.7 MHz; (0.0075 × VPOS)/dB
At 45 MHz
Untrimmed at 10.7 MHz
Sinusoidal Input; Independent of VPOS
–75 dBm to +5 dBm Input Signal at 10.7 MHz
Input Level = –75 dBm
Input Level = –35 dBm
Input Level = +5 dBm
After Calibration at –35 dBm at 10.7 MHz
TMIN to TMAX
From Onset of Input Signal Until Output Reaches
95% of Final Value
–15
–1.5
–3
Time Delay Following HI Transition Until
Device Meets Full Specifications
AC Coupled with 100 pF Coupling Capacitors
Logical HI Input (See Figure 12)
Logical LO Input
AD606J
Typ
50
100
80
2,500
2
Units
MHz
MHz
dB
Ω
pF
+1.5
dB
1.2
0.48
±3
mA
mA
Degrees
37.5
35
±5
+15
–88.33
0.4
+1.5
0.5
2
3.5
+3
mV/dB
mV/dB
%
dBm
dB
V
V
V
dB
400
ns
3.5
µs
1
4
nA
µA
4.5
Zero Signal Input
TMIN to TMAX
TMIN to TMAX
Max
5.5
13
13
65
20
200
V
mA
mA
µA
Specifications subject to change without notice.
–2–
REV. B
AD606
ABSOLUTE MAXIMUM RATINGS 1
PIN FUNCTION DESCRIPTIONS
Supply Voltage VPOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . +9 V
Internal Power Dissipation2 . . . . . . . . . . . . . . . . . . . 600 mW
Operating Temperature Range . . . . . . . . . . . . . 0°C to +70°C
Storage Temperature Range . . . . . . . . . . . . –65°C to +150°C
Lead Temperature Range (Soldering 60 sec) . . . . . . . . +300°C
NOTES
1
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
2
Specification is for device in free air:
16-Lead Plastic DIP Package: θJA = 85°C/W
16-Lead SOIC Package: θJA = 100°C/W
Pin Mnemonic Function
1
INLO
2
COMM
3
4
ISUM
ILOG
5
BFIN
ORDERING GUIDE
Model
Temperature Package
Range
Description
AD606JN
AD606JR
0°C to +70°C 16-Lead Plastic DIP
0°C to +70°C 16-Lead Narrow-Body
SOIC
AD606JR-REEL 0°C to +70°C 13" Tape and Reel
AD606JR-REEL7 0°C to +70°C 7" Tape and Reel
AD606-EB
Evaluation Board
AD606JCHIPS
0°C to +70°C Die
PIN DESCRIPTION
Plastic DIP (N)
and
Small Outline (R)
Packages
INLO 1
16
INHI
COMM 2
15
COMM
ISUM 3
14
PRUP
13
VPOS
ILOG 4
AD606
TOP VIEW
BFIN 5 (Not to Scale) 12 FIL1
VLOG 6
11
FIL2
OPCM 7
10
LADJ
LMLO 8
9
LMHI
6
VLOG
Package
Option
7
OPCM
N-16
R-16A
8
LMLO
9
LMHI
10
LADJ
11
FIL1
12
FIL2
13
VPOS
14
PRUP
15
COMM
16
INHI
R-16A
R-16A
DIFFERENTIAL RF INPUT
–75 dBm to +5 dBm, Inverting, AC Coupled.
POWER SUPPLY COMMON
Connect to Ground.
LOG DETECTOR SUMMING NODE
LOG CURRENT OUTPUT
Normally No Connection; 2 µA/dB Output
Current.
BUFFER INPUT
Optionally Used to Realize Low Frequency
Post-Demodulation Filters.
BUFFERED LOG OUTPUT
37.5 mV/dB (100 mV to 4.5 V).
OUTPUT COMMON
Connect to Ground.
DIFFERENTIAL LIMITER OUTPUT
1.2 mA Full-Scale Output Current. Open
Collector Output Must Be “Pulled” Up to
VPOS with R ≤ 400 Ω.
DIFFERENTIAL LIMITER OUTPUT
1.2 mA Full-Scale Output Current. Open
Collector Output Must Be “Pulled” Up to
VPOS with R ≤ 400 Ω.
LIMITER LEVEL ADJUSTMENT
Optionally Used to Adjust Limiter Output
Current.
OFFSET LOOP LOW-PASS FILTER
Normally No Connection; a Capacitor Between
FIL1 and FIL2 May Be Added to Lower the
Filter Cutoff Frequency.
OFFSET LOOP LOW-PASS FILTER
Normally No Connection; See Above.
POSITIVE SUPPLY
Connect to +5 V at 13 mA.
POWER UP
CMOS (5 V) Logical High = Device On
(≈ 65 mW).
CMOS (0 V) Logical Low = Device Off
(≈ 325 µW).
POWER SUPPLY COMMON
Connect to Ground.
DIFFERENTIAL RF INPUT
–75 dBm to +5 dBm, Noninverting, AC-Coupled.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD606 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
REV. B
–3–
WARNING!
ESD SENSITIVE DEVICE
AD606
INPUT LEVEL CONVENTIONS
results in an alternating input voltage being transformed into a
quasi-dc (rectified and filtered) output voltage.
RF logarithmic amplifiers usually have their input specified in
“dBm,” meaning “decibels with respect to 1 mW.” Unfortunately, this is not precise for several reasons.
The single supply nature of the AD606 results in common-mode
level of the inputs INHI and INLO being at about +2.5 V (using the recommended +5 V supply). In normal ac operation,
this bias level is developed internally and the input signal is
coupled in through dc blocking capacitors. Any residual dc
offset voltage in the first stage limits the logarithmic accuracy for
small inputs. In ac operation, this offset is automatically and
continuously nulled via a feedback path from the last stage, provided that the pins INHI and INLO are not shorted together, as
would be the case if transformer coupling were used for the signal.
1. Log amps respond not to power but to voltage. In this respect, it would be less ambiguous to use “dBV” (decibels
referred to 1 V) as the input metric. Also, power is dependent
on the rms (root mean-square) value of the signal, while log
amps are not inherently rms responding.
2. The response of a demodulating log amp depends on the
waveform. Convention assumes that the input is sinusoidal.
However, the AD606 is capable of accurately handling any
input waveform, including ac voltages, pulses and square
waves, Gaussian noise, and so on. See the AD640 data sheet,
which covers the effect of waveform on logarithmic intercept,
for more information.
While any logarithmic amplifier must eventually conform to the
basic equation shown above, which, with appropriate elaboration, can also fully account for the effect of the signal waveform
on the effective intercept,1 it is more convenient in RF applications to use a simpler expression. This simplification results
from first, assuming that the input is always sinusoidal, and
second, using a decibel representation for the input level. The
standard representation of RF levels is (incorrectly, in a log amp
context) in terms of power, specifically, decibels above 1 milliwatt (dBm) with a presumed impedance level of 50 Ω. That
being the case, we can rewrite the transfer function as
3. The impedance in which the specified power is measured is
not always stated. In the log amp context it is invariably
assumed to be 50 Ω. Thus, 0 dBm means “1 mW rms in 50 Ω,”
and corresponds to an rms voltage of (1 mW × 50 Ω), or
224 mV.
Popular convention requires the use of dBm to simplify the
comparison of log amp specifications. Unless otherwise stated,
sinusoidal inputs expressed as dBm in 50 Ω are used to specify
the performance of the AD606 throughout this data sheet. We
will also show the corresponding rms voltages where it helps to
clarify the specification. Noise levels will likewise be given in
dBm; the response to Gaussian noise is 0.5 dB higher than for a
sinusoidal input of the same rms value.
VLOG = VY ( PIN – PX )
where it must be understood that PIN means the sinusoidal input
power level in a 50 Ω system, expressed in dBm, and PX is the
intercept, also expressed in dBm. In this case, PIN and PX are
simple, dimensionless numbers. (PX is sometimes called the
“logarithmic offset,” for reasons which are obvious from the
above equation.) VY is still defined as the logarithmic slope,
usually specified as so many millivolts per decibel, or mV/dB.
Note that dynamic range, being a simple ratio, is always specified simply as “dB”, and the slope of the logarithmic transfer
function is correctly specified as “mV/dB,” NOT as “mV/dBm.”
In the case of the AD606, the slope voltage, VY, is nominally
750 mV when operating at VPOS = 5 V. This can also be expressed as 37.5 mV/dB or 750 mV/decade; thus, the 80 dB
range equates to 3 V. Figure 1 shows the transfer function of the
AD606. The slope is closely proportional to VPOS, and can more
generally be stated as VY = 0.15 × VPOS. Thus, in those applications where the scaling must be independent of supply voltage,
this must be stabilized to the required accuracy. In applications
where the output is applied to an A/D converter, the reference
LOGARITHMIC SLOPE AND INTERCEPT
A generalized logarithmic amplifier having an input voltage VIN
and output voltage VLOG must satisfy a transfer function of the
form
VLOG = VY log10 (VIN /VX )
where, in the case of the AD606, the voltage VIN is the difference between the voltages on pins INHI and INLO, and the
voltage VLOG is that measured at the output pin VLOG. VY and
VX are fixed voltages that determine the slope and intercept of
the logarithmic amplifier, respectively. These parameters are
inherent in the design of a particular logarithmic amplifier,
although may be adjustable, as in the AD606. When VIN = VX,
the logarithmic argument is one, hence the logarithm is zero. VX
is, therefore, called the logarithmic intercept voltage because the
output voltage VLOG crosses zero for this input. The slope voltage VY is can also be interpreted as the “volts per decade” when
using base-10 logarithms as shown here.
4
3.5
VLOG – Volts DC
3
Note carefully that VLOG and VLOG in the above paragraph
(and elsewhere in this data sheet) are different. The first is a
voltage; the second is a pin designation.
2.5
SLOPE = 37.5mV/dB
2
1.5
1
0.5
INTERCEPT
AT –88.33dBm
0
–100
This equation suggests that the input VIN is a dc quantity, and,
if VX is positive, that VIN must likewise be positive, since the
logarithm of a negative number has no simple meaning. In fact,
in the AD606, the response is independent of the sign of VIN
because of the particular way in which the circuit is built. This
is part of the demodulating nature of the amplifier, which
–80
–60
–40
–20
INPUT SIGNAL – dBm
0
+20
Figure 1. Nominal Transfer Function
1
See, for example, the AD640 data sheet, which is published in Section 3 of
the Special Linear Reference Manual or Section 9.3 of the 1992 Amplifier
Applications Guide.
–4–
REV. B
AD606
for that converter should be a fractional part of VPOS, if possible.
The slope is essentially independent of temperature.
ILOG and OPCM (output common, which is usually grounded).
The nominal slope at this point is 18.75 mV/dB (375 mV/
decade).
The intercept PX is essentially independent of either the supply
voltage or temperature. However, the AD606 is not factory
calibrated, and both the slope and intercept may need to be
externally adjusted. Following calibration, the conformance to
an ideal logarithmic law will be found to be very close, particularly at moderate frequencies (see Figure 14), and still acceptable at the upper end of the frequency range (Figure 15).
In applications where VLOG is taken to an A/D converter which
allows the use of an external reference, this reference input
should also be connected to the same +5 V supply. The power
supply voltage may be in the range +4.5 V to +5.5 V, providing
a range of slopes from nominally 33.75 mV/dB (675 mV/ decade) to 41.25 mV/dB (825 mV/decade).
A buffer amplifier, having a gain of two, provides a final output
scaling at VLOG of 37.5 mV/dB (750 mV/decade). This lowimpedance output can run from close to ground to over +4 V
(using the recommended +5 V supply) and is tolerant of resistive and capacitive loads. Further filtering is provided by a conjugate pole pair, formed by internal capacitors which are an
integral part of the output buffer. The corner frequency of the
overall filter is 2 MHz, and the 10%–90% rise time is 150 ns.
Later, we will show how the slope and intercept can be altered
using simple external adjustments. The direct buffer input
BFIN is used in these cases.
CIRCUIT DESCRIPTION
Figure 2 is a block diagram of the AD606, which is a complete
logarithmic amplifier system in monolithic form. It uses a total
of nine limiting amplifiers in a “successive detection” scheme to
closely approximate a logarithmic response over a total dynamic
range of 90 dB (Figure 2). The signal input is differential, at
nodes INHI and INLO, and will usually be sinusoidal and ac
coupled. The source may be either differential or single-sided;
the input impedance is about 2.5 kΩ in parallel with 2 pF. Seven
of the amplifier/detector stages handle inputs from –80 dBm
(32 µV rms) up to about –14 dBm (45 mV rms). The noise floor
is about –83 dBm (18 µV rms). Another two stages receive the
input attenuated by 22.3 dB, and respond to inputs up to
+10 dBm (707 mV rms). The gain of each of these stages is
11.15 dB and is accurately stabilized over temperature by a
precise biasing system.
The last limiter output is available as complementary currents
from open collectors at pins LMHI and LMLO. These currents
are each 1.2 mA typical with LADJ grounded and may be converted to voltages using external load resistors connected to
VPOS; typically, a 200 Ω resistor is used on just one output.
The voltage gain is then over 90 dB, resulting in a hard-limited
output for all input levels down to the noise floor. The phasing
is such that the voltage at LMHI goes high when the input
(INHI to INLO) is positive. The overall delay time from the
signal inputs to the limiter outputs is 8 ns. Of particular importance is the phase stability of these outputs versus input level. At
50 MHz, the phase typically remains within ± 4° from –70 dBm
to +5 dBm. The rise time of this output (essentially a square
wave) is about 1.2 ns, resulting in clean operation to more than
70 MHz.
The detectors provide full-wave rectification of the alternating
signal present at each limiter output. Their outputs are in the
form of currents, proportional to the supply voltage. Each cell
incorporates a low-pass filter pole, as the first step in recovering
the average value of the demodulated signal, which contains
appreciable energy at even harmonics of the input frequency. A
further real pole can be introduced by adding a capacitor between the summing node ISUM and VPOS. The summed detector output currents are applied to a 6:1 reduction current
mirror. Its output at ILOG is scaled 2 µA/dB, and is converted
to voltage by an internal load resistor of 9.375 kΩ between
INHI
COMM
PRUP
VPOS
FIL1
FIL2
LADJ
LMHI
16
15
14
13
12
11
10
9
REFERENCE
AND POWER-UP
30pF
360kV
X1
30kV
360kV
30pF
30kV
OFFSET-NULL
LOW-PASS FILTER
1.5kV
9.375kV
12mA/dB
HIGH-END
DETECTORS
1.5kV
ONE-POLE
FILTER
AD606
2pF
9.375kV
TWO-POLE
SALLEN-KEY
FILTER
X2
2pF
2mA/dB
1
2
3
4
5
6
7
8
INLO
COMM
ISUM
ILOG
BFIN
VLOG
OPCM
LMLO
Figure 2. Simplified Block Diagram
REV. B
FINAL
LIMITER
MAIN SIGNAL PATH
11.15dB/STAGE
250V
–5–
AD606
The loop’s effect is felt only at the lower end of the dynamic
range, that is, from about 80 dBm to –70 dBm, and when the
signal frequency is near the lower edge of the passband. Thus,
the small signal results which are obtained using the suggested
model are not indicative of the ac response at moderate to high
signal levels. Figure 4 shows the response of this model for the
default case (using CC = 100 pF and CZ = 0) and with CZ =
150 pF. In general, a maximally flat ac response occurs when CZ
is roughly twice CC (making due allowance for the internal
30 pF capacitors). Thus, for audio applications, one can use
CC = 2.7 µF and CZ = 4.7 µF to achieve a high-pass corner
(–3 dB) at 25 Hz.
Offset-Control Loop
The offset-control loop nulls the input offset voltage, and sets
up the bias voltages at the input pins INHI and INLO. A full
understanding of this offset-control loop is useful, particularly
when using larger input coupling capacitors and an external
filter capacitor to lower the minimum acceptable operating
frequency. The loop’s primary purpose is to extend the lower
end of the dynamic range in the case where the offset voltage of
the first stage should be high enough to cause later stages to
prematurely enter limiting, because of the high dc gain (about
8000) of the main amplifier system. For example, an offset
voltage of only 20 µV would become 160 mV at the output of
the last stage in the main amplifier (before the final limiter section), driving the last stage well into limiting. In the absence of
noise, this limiting would simply result in the logarithmic output
ceasing to become any lower below a certain signal level at the
input. The offset would also degrade the logarithmic conformance in this region. In practice, the finite noise of the first stage
also plays a role in this regard, even if the dc offset were zero.
90
80
RELATIVE OUTPUT – dB
70
Figure 3 shows a representation of this loop, reduced to essentials. The figure closely corresponds to the internal circuitry,
and correctly shows the input resistance. Thus, the forward gain
of the main amplifier section is 7 × 11.15 dB, but the loop gain
is lowered because of the attenuation in the network formed by
RB1 and RB2 and the input resistance RA. The connection
polarity is such as to result in negative feedback, which reduces
the input offset voltage by the dc loop gain, here about 50 dB,
that is, by a factor of about 316. We use a differential representation, because later we will examine the consequences to the
power-up response time in the event that the ac coupling capacitors CC1 and CC2 do not exactly match. Note that these capacitors, as well as forming a high-pass filter to the signal in the
forward path, also introduce a pole in the feedback path.
CZ
To optimize the low level accuracy, that is, achieve a highly
damped pulse response in this filter, it is recommended to include a resistor RZ in series with an increased value of CZ. Some
experimentation may be necessary, but for operation in the
range 3 MHz to 70 MHz, values of CC = 100 pF, CZ = 1 nF
and RZ = 2 kΩ are near optimal. For operation down to 100 kHz
use CC = 10 nF, CZ = 0.1 µF and RZ = 13 kΩ. Figure 5 shows
typical connections for the AD606 with these filter components
added.
TO FINAL
LIMITER
STAGE
RZ
FIL1
+1
Figure 3. Offset Control Loop
Internal resistors RF1 and RF2 in conjunction with grounded
capacitors CF1 and CF2 form a low-pass filter at 15 kHz. This
frequency can optionally be lowered by the addition of an external capacitor CZ, and in some cases a series resistor RZ. This, in
conjunction with the low-pass section formed at the input coupling, results in a two-pole high-pass response, falling of at
40 dB/decade below the corner frequency. The damping factor
of this filter depends on the ratio CZ/CC (when CZ>>CF) and
also on the value of RZ.
RZ
FIL2
LADJ
LMHI
VLOG
OPCM
LMLO
FIL1
VPOS
INHI
CZ
The inclusion of this control loop has no effect on the high frequency
response of the AD606. Nor does it have any effect on the low frequency response when the input amplitude is substantially above the
input offset voltage.
BFIN
INLO
AD606JN
ILOG
RF1
360kV
100M
However, the maximally flat ac response is not optimal in two
special cases. First, where the RF input level is rapidly pulsed,
the fast edges will cause the loop filter to ring. Second, ringing
can also occur when using the power-up feature, and the ac
coupling capacitors do not exactly match in value. We will examine the latter case in a moment. Ringing in a linear amplifier
is annoying, but in a log amp, with its much enhanced sensitivity to near zero signals, it can be very disruptive.
PRUP
CF1
30pF
1M
10M
INPUT FREQUENCY – Hz
Figure 4. Frequency Response of Offset Control Loop for
CZ = 0 pF and CZ = 150 pF (CC = 100 pF)
CC2
RB2
30kV
100k
ISUM
0V
10
COMM
78dB
20
–20
10k
CC1
RA
2.5kV
30
–10
FIL2
RF2
360kV
CZ = 0pF
40
COMM
CF2
30pF
50
0
+1
RB1
30kV
CZ = 150pF
60
Figure 5. Use of CZ and RZ for Offset Control Loop
Compensation
–6–
REV. B
AD606
For operation above 10 MHz, it is not necessary to add the
external capacitors CF1, CF2, and CZ, although an improvement in low frequency noise can be achieved by so doing (see
APPLICATIONS). Note that the offset control loop does not
materially affect the low-frequency cutoff at high input levels,
when the offset voltage is swamped by the signal.
APPLICATIONS
Note that the AD606 has more than 70 MHz of input bandwidth and 90 dB of gain! Careful shielding is needed to realize
its full dynamic range, since nearly all application sites will be
pervaded by many kinds of interference, radio and TV stations,
etc., all of which the AD606 faithfully hears. In bench evaluation, we recommend placing all of the components in a shielded
box and using feedthrough decoupling networks for the supply
voltage. In many applications, the AD606’s low power drain
allows the use of a 6 V battery inside the box.
Power-Up Interface
The AD606 features a power-saving mode, controlled by the
logic level at Pin 14 (PRUP). When powered down, the quiescent current is typically 65 µA, or about 325 µW. A CMOS
logical HIGH applied to PRUP activates both internal references, and the system becomes fully functional within about
3.5 µs. When this input is a CMOS logical LOW, the system
shuts down to the quiescent level within about 5 µs.
Basic RSSI Application
Figure 6 shows the basic RSSI (Receiver Signal Strength Indicator) application circuit, including the calibration adjustments,
either or both of which may be omitted in noncritical applications. This circuit may be used “as is” in such measurement
applications as the log/IF strip in a spectrum or network analyzer or, with the addition of an FM or QPSK demodulator fed
by the limiter outputs, as an IF strip in such communications
applications as a GSM digital mobile radio or FM receiver.
The power-up time is somewhat dependent on the signal level
and can be degraded by mismatch of the input coupling capacitors. The explanation is as follows. When the AD606 makes the
transition from powered-down to fully active, the dc bias voltage
at the input nodes INHI and INLO (about +2.5 V) inevitably
changes slightly, as base current in the input transistors flows in
the bias resistors. In fact, first-order correction for this is included in the specially designed offset buffer amplifier, but even
a few millivolts of change at these inputs represents a significant
equivalent “dBm” level.
The slope adjustment works in this way: the buffer amplifier
(which forms part of a Sallen-Key two-pole filter, see Figure 2)
has a dc gain of plus two, and the resistance from BFIN (buffer
in) to OPCM (output common) is nominally 9.375 kΩ. This
resistance is driven from the logarithmic detector sections with a
current scaled 2 µA/dB, generating 18.75 mV/dB at BFIN,
hence 37.5 mV/dB at VLOG Now, a resistor (R4 in Figure 6)
connected directly between BFIN and VLOG would form a
controlled positive-feedback network with the internal 9.375 kΩ
resistor which would raise the gain, and thus increase the slope
voltage, while the same external resistor connected between
BFIN and ground would form a shunt across the internal resistor and reduce the slope voltage. By connecting R4 to a potentiometer R2 across the output, the slope may be adjusted either
way; the value for R4 shown in Figure 6 provides approximately
± 10% range, with essentially no effect on the slope at the
midposition.
Now, if the coupling capacitors do not match exactly, some
fractional part of this residual voltage step becomes coupled into
the amplifier. For example, if there is a 10% capacitor mismatch, and INHI and INLO jump 20 mV at power-up, there is
a 2 mV pulse input to the system, which may cause the offset
control loop to ring. Note that 2 mV is roughly 40 times greater
than the amplitude of a sinusoidal input at –75 dBm. As long as
the ringing persists, the AD606 will be “blind” to the actual
input, and VLOG will show major disturbances.
The solution to this problem is first, to ensure that the loop
filter does not ring, and second, to use well-matched capacitors
at the signal input. Use the component values suggested above
to minimize ringing.
The intercept may be adjusted by adding a small current into
BFIN via R1 and R3. The AD606 is designed to have the nominal intercept value of –88 dBm when R1 is centered using this
network, which provides a range of ± 5 dB.
+5V
0.1mF
LMHI
LADJ
NC
FIL2
VPOS
PRUP
COMM
INHI
NC
FIL1
100pF
RF INPUT
R5
200V
LMLO
OPCM
VLOG
BFIN
ISUM
COMM
INLO
ILOG
AD606
51.1V
100pF
+5V
NC = NO CONNECT
R1
200kV
INTERCEPT
ADJUSTMENT
65dB
R3
412kV
R4
174kV
R2
50kV
SLOPE
ADJUSTMENT
610%
LIMITER OUTPUT
LOGARITHMIC
OUTPUT
Figure 6. Basic Application Circuit Showing Optional Slope and Intercept Adjustments
REV. B
–7–
AD606
Adjustment Procedure
In contrast to the limited dynamic range of the diode and
thermistor-styled sensors used in power meters, the AD606 can
measure signals from below –80 dBm to over +10 dBm. An
optional 50 Ω termination is included in the figure; this could
form the lower arm of an external attenuator to accommodate
larger signal levels. By the simple expedient of using a 13 dB
attenuator, the LCD reading now becomes dBV (decibels above
1 V rms). This requires a series resistor of 174 Ω, presenting an
input resistance of 224 Ω. Alternatively, the input resistance can
be raised to 600 Ω using 464 Ω and 133 Ω. It is important to
note that the AD606 inputs must be ac coupled. To extend the
low frequency range, use larger coupling capacitors and an
external loop filter, as outlined earlier.
The slope and intercept adjustments interact; this can be minimized by reducing the resistance of R1 and R2, chosen here to
minimize power drain. Calibration can be achieved in several
ways: The simplest is to apply an RF input at the desired operating frequency which is amplitude modulated at a relatively
low frequency (say 1 kHz to 10 kHz) to a known modulation
index. Thus, one might choose a ratio of 2 between the maximum and minimum levels of the RF amplitude, corresponding
to a 6 dB (strictly, 6.02 dB) change in input level. The average
RF level should be set to about –35 dBm (the midpoint of the
AD606’s range). R2 is then adjusted so that the 6 dB input
change results in the desired output voltage change, for example, 226 mV at 37.5 mV/dB.
The nominal 0.5 V to 3.5 V output of the AD606 (for a –75 dBm
to +5 dBm input) must be scaled and level shifted to fit within
the +1 V to +4.5 V common-mode range of the ICL7136 for
the +5 V supply used. This is achieved by the passive resistor
network of R1, R2, and R3 in conjunction with the bias networks of R4 through R7, which provide the ICL7136 with its
reference voltage, and R9 through R11, which set the intercept.
The ICL7136 measures the differential voltage between INHI
and INLO, which ranges from –75 mV to +5 mV for a
–75 dBm to +5 dBm input.
A better choice would be a 4:1 ratio (12.04 dB), to spread the
residual error out over a larger segment of the whole transfer
function. If a pulsed RF generator is available, the decibel increment might be enlarged to 20 dB or more. Using just a fixedlevel RF generator, the procedure is more time consuming, but
is carried out in just the same way: manually change the level by
a known number of decibels and adjust R2 until VLOG varies by
the corresponding voltage.
Having adjusted the slope, the intercept may now be simply adjusted using a known input level. A value of –35 dBm (397.6 mV
rms, or 400 mV to within 0.05 dB) is recommended, and if the
standard scaling is used (PX = –88.33 dBm, VY = 37.5 mV/dB),
then VLOG should be set to +2 V at this input level.
To calibrate the power meter, first adjust R6 for 100 mV between REF HI and REF LO. This sets the initial slope. Then
adjust R10 to set INLO 80 mV higher than INHI. This sets the
initial intercept. The slope and intercept may now be adjusted
using a calibrated signal generator as outlined in the previous
section.
A Low Cost Audio Through RF Power Meter
Figure 7 shows a simple power meter that uses the AD606 and
an ICL7136 3-1/2 digit DMM IC driving an LCD readout. The
circuit operates from a single +5 V supply and provides direct
readout in dBm, with a resolution of 0.1 dBm.
To extend the low frequency limit of the system to audio frequencies, simply change C1, C2, and C3 to 4.7 µF.
The limiter output of the AD606 may be used to drive the highimpedance input of a frequency counter.
+5V
0.1mF
+5V
174V
0.1mF
C1*
100pF
dBm
INPUT
OPTIONAL
DRIVE TO
FREQUENCY
COUNTER
+5V
C3*
150pF
R4
4.99kV
DISPLAY
36
REF HI
35
REF LO
–75.0
LMHI
LADJ
FIL2
FIL1
VPOS
PRUP
COMM
INHI
R5
4.32kV
NC
LMLO
BFIN
NC
OPCM
ILOG
NC
VLOG
ISUM
INLO
C2*
100pF
R6
500V
200V
+5V
+5V
AD606JN
51.1V
COMM
dBV
INPUT
R9
5kV
180kV
100mV
39
32
R8
100kV
50pF
COMM
38
2.513V NOM
INLO
34
R10
100kV
* FOR AUDIO MEASUREMENTS CHANGE
C1, C2, AND C3 TO 4.7mF; POSITIVE POLARITY
CONNECT TO PINS 1, 16
+5V
NC = NO CONNECT
R7
162V
40
R1
1MV
0.1mF
80mV
FOR
0dBm
SIGNAL
INPUT
33
ICL7136CPL
C4
1mF
1.8MV
R2
54.9kV
31
R3
54.9kV
0.1mF
2.433V NOM
INHI
0.047mF
V–
Figure 7. A Low Cost RF Power Meter
–8–
REV. B
AD606
0.1mF
20dB
ATTENUATOR
C1
4.7mF
+
LMHI
LADJ
OPCM
FIL1
VPOS
BFIN
NC
NC
NC
LMLO
ILOG
R2
100V
ISUM
COMM
AD606JN
INLO
C2
4.7mF
+
FIL2
C3
680pF
VLOG
R5
51.1V
PRUP
R1
100V
INHI
R4
453V
C4
4.7mF
COMM
AC
INPUT
+5V
LOW-PASS
FILTER
TO
DVM
R3
1kV
DIECAST BOX
NC = NO CONNECT
Figure 8. Circuit for Low Frequency Measurements
Low Frequency Applications
With reasonably sized input coupling capacitors and an optional
input low-pass filter, the AD606 can operate to frequencies as
low as 200 Hz with good log conformance. Figure 8 shows the
schematic, with the low-pass filter included in the dashed box.
This circuit should be built inside a die cast box and the signal
brought in through a coaxial connector. The circuit must also
have a low-pass filter to reject the attenuated RF signals that
would otherwise be rectified along with the desired signal and
be added to the log output. The shielded and filtered circuit has
a 90 dB dynamic range, as shown in Figure 9.
This low-pass filter introduces some attenuation due to R1 and
R2 in conjunction with the 2.5 kΩ input resistance of the
AD606. To minimize this effect, the value of R1 and R2 should
be kept as small as possible–100 Ω is a good value since it balances the need to reduce the attenuation as mentioned above
with the requirement for R1 and R2 to be much larger then the
impedance of C1 and C2 at the low-pass corner frequency, in
our case about 1 MHz.
90dB
4
3.5V
In this circuit, R4 and R5 form a 20 dB attenuator that extends
the input range to 10 V rms. R3 isolates loads from VLOG.
Capacitors C1 and C2 (4.7 µF each), R1, R2, and the AD606’s
input resistance of 2.5 kΩ form a 100 Hz high-pass filter that is
before the AD606; the corner frequency of this filter must be
well below the lowest frequency of interest. In addition, the
offset-correction loop introduces another pole at low signal
levels that is transformed into another high-pass filter because it
is in a feedback path. This indicates that there has to be a
gradual transition from a 40 dB roll off at low signal levels to a
20 dB roll off at high signal levels, at which point the feedback
low pass filter is effectively disabled since the incoming signal
swamps the feedback signal.
VLOG – Volts DC
3
2
1kHz – 10MHz
100Hz
1
0
–80
–60
–40
–20
0
20
40
INPUT SIGNAL – dBm
Figure 9. Performance of Low Frequency Circuit at 100 Hz
and 1 kHz to 10 MHz (Note Attenuation)
REV. B
–9–
8/30/99 9 AM
AD606–Typical Performance Characteristics
5
–0.5
–1.5
70MHz
45MHz
–2.5
10.7MHz
–3.5
–4.5
–5.5
–6.5
–80 –70 –60 –50 –40 –30 –20 –10
INPUT LEVEL – dBm
0
20
Figure 10. Normalized Limiter
Amplitude Response vs. Input Level
at 10.7 MHz, 45 MHz and 70 MHz
14
10.7MHz
POWER SUPPLY CURRENT – mA
NORMALIZED PHASE SHIFT – Degrees
NORMALIZED LIMITER OUTPUT – dB
0.5
0 45MHz
–5
70MHz
–10
–15
–20
–25
–80
–60
–40
–20
INPUT LEVEL – dBm
0
3
2.5
2
VS = 5V
1.5
VS = 4.5V
1
2
1
TA = –258C
TA = +258C
0
–1
TA = +708C
–2
–3
0.5
0
–80
LOGARITHMIC ERROR – dB
VLOG – Volts DC
LOGARITHMIC ERROR – dB
VS = 5.5V
–60
–40
–20
0
10
INPUT POWER – dBm
–4
–80
4
2
0
0.5
1
1.5 2 2.5 3 3.5 4
PRUP VOLTAGE – Volts
4.5
5
4
3
3.5
6
5
TA = +258C
4
8
Figure 12. Supply Current vs. PRUP
Voltage at +25 °C
4
4.5
10
0
20
Figure 11. Normalized Limiter
Phase Response vs. Input Level at
10.7 MHz, 45 MHz, and 70 MHz
12
3
2
TA = –258C
TA = +258C
1
0
–1
–2
–3
TA = +708C
–4
–40
0
–60
–20
INPUT AMPLITUDE – dBm
10
–5
–80
–60
–40
–20
0
INPUT AMPLITUDE – dBm
10
Figure 13. VLOG Plotted vs. Input
Level at 10.7 MHz as a Function of
Power Supply Voltage
Figure 14. Logarithmic Conformance as a Function of Input Level at
10.7 MHz at –25 °C, +25 °C, and
+70 °C
Figure 15. Logarithmic Conformance as a Function of Input Level at
45 MHz at –25 °C, +25 °C, and +70 °C
Figure 16. Limiter Response at
Onset of 10.7 MHz Modulated Pulse
at –75 dBm Using 200 pF Input
Coupling Capacitors
Figure 17. VLOG Response to a
10.7 MHz CW Signal Modulated by
a 25 µ s Wide Pulse with a 25 kHz
Repetition Rate Using 200 pF Input
Coupling Capacitors. The Input Signal Goes from +5 dBm to –75 dBm
in 20 dB Steps.
Figure 18. Limiter Response at
Onset of 70 MHz Modulated Pulse
at –55 dBm Using 200 pF Input
Coupling Capacitors
–10–
REV. B
AD606
Figure 19. VLOG Output for a Pulsed
10.7 MHz Input; Top Trace: –35 dBm
to +5 dBm; Middle Trace: –15 dBm to
–55 dBm; Bottom Trace: –35 dBm to –
75 dBm
Figure 20. Example of Test Signal
Used for Figure 19
Figure 21. VLOG Output for 10.7 MHz
CW Input with PRUP Toggled ON
and OFF; Top Trace: +5 dBm Input;
Middle Trace: –35 dBm Input; Bottom
Trace: –75 dBm; PRUP Input from
HP8112A: 0 to 4 V, 10 µ s Pulsewidth
with 10 kHz Repetition Rate
+5V
0.1mF
LMHI
LADJ
FIL2
FIL1
VPOS
PRUP
NC
LMLO
BFIN
NC
OPCM
ILOG
NC
VLOG
ISUM
HEWLETT PACKARD
8112A PULSE
GENERATOR
C2
100pF
NC = NO CONNECT
Figure 22. Test Setup for Characterization Data
REV. B
–11–
200V
+5V
AD606JN
51.1V
SWEPT GAIN
TESTS
INLO
MODULATED
PULSE
TESTS
INHI
AD602
C3
150pF
C1
100pF
COMM
FLUKE 6082A
SYNTHESIZED
SIGNAL
GENERATOR
RF
INPUT
COMM
–10dB TO +30dB
(10.7MHz SWEPT
GAIN TESTS ONLY)
200V
TEKTRONIX 7704A
MAINFRAME
OSCILLOSCOPE
10 x
P6201
ATTN PROBES
7A18
AMP
6137
PROBES
7A24
AMP
7B53A
TIME-BASE
AD606
OUTLINE DIMENSIONS
Dimensions shown in inches and (mm).
16-Lead Plastic DIP
(N-16)
0.31 (7.87)
16
9
1
8
0.25 (6.35)
0.300 (7.62)
0.35
(0.89)
PIN 1
0.18
(4.57)
0.125 (3.18)
MIN
0.018
(0.46)
0.033
(0.84)
0.100
(2.54)
BSC
C1698b–0–8/99
0.87 (22.1) MAX
0.18 (4.57)
MAX
0.011
(0.28)
SEATING
PLANE
16-Lead Narrow-Body SOIC
(R-16A)
0.3937 (10.00)
0.3859 (9.80)
PIN 1
16
9
1
8
0.050 (1.27)
BSC
0.0098 (0.25)
0.0040 (0.10)
0.2440 (6.20)
0.2284 (5.80)
0.0688 (1.75)
0.0532 (1.35)
0.0196 (0.50)
3 458
0.0099 (0.25)
88
0.0192 (0.49) SEATING 0.0099 (0.25) 08 0.0500 (1.27)
PLANE
0.0138 (0.35)
0.0160 (0.41)
0.0075 (0.19)
PRINTED IN U.S.A.
0.1574 (4.00)
0.1497 (3.80)
–12–
REV. B