Marktech LP377THR1-70G-01-MT Specification for cotco led lamp Datasheet

COTCO LUMINANT DEVICE (HUIZHOU) LTD.
SPECIFICATION FOR COTCO LED LAMP
Document No:
Model No :
Rev. No:
Date:
SPE/LP377THR1-70G-01-MT
LP377THR1-70G-01-MT
02
2005-09-15
Description:
70 Degree 7.6 x 7.6mm LED Lamp in High
Red Color with Water Transparent Lens and
Stopper
*This specification is only for MT
Dice Material:
AlGaInP
Confirmed
by Customer:
Date:
ATTENTION
OBSERVE PRECAUTIONS
ELECTROSTATIC
SENSITIVE DEVICES
For part availability and ordering information please call Toll Free: 800.984.5337
Website: www.marktechopto.com | Email: [email protected]
Document No. SPE/LP377THR1-70G-01-MT
Rev. No.
02
Applications:
-
Dimension Drawing
Advertising Signs
Indicators
Automotive Lighting
Absolute Maximum Ratings at Ta = 25°C
Items
Absolute maximum
Symbol
Rating
Unit
Forward Current*2
IF
70
mA
Peak Forward Current*1
IFP
200
mA
Reverse Voltage
VR
5
V
Power Dissipation
PD
220
mW
Operation Temperature
Topr
-40 ~ +100
°C
Storage Temperature
Tstg
-40 ~ +100
°C
Lead Soldering
Temperature
Max.260°C for 5 sec Max.
Tsol
(3mm from the base of the epoxy bulb)
*1 pulse width <=0.1msec duty <=1/10
*2 Heat sink is recommended to be adequated if the device is operated at ambient temperatures higher than 25 deg C. For long term
performance the drive currents between 10mA and 50mA are recommended. Please contact COTCO sales representative for more
information on recommended drive conditions.
Typical Electrical & Optical Characteristics ( Ta = 25°C)
Items
Symbol
Condition
Min.
Typ.
Max.
Unit
Forward Voltage
VF
IF = 70mA
---
2.6
3.2
V
Reverse Current
IR
VR = 5V
---
---
100
µA
Dominant Wavelength
λD
IF = 70mA
620
628
637
nm
Luminous Flux
ΦV
IF = 70mA
3000
4500
---
mlm
50% Power Angle
2θ½
IF = 70mA
---
70
---
deg
2/4
Format #: COTCO-D-074
REV.3
Document No. SPE/LP377THR1-70G-01-MT
Rev. No.
02
Standard bins for LP377THR1-70G-01-MT (IF = 70mA):
Lamps are sorted to Luminous Flux –ΦV , VF & Dominant Wavelength –λD bins shown.
Orders for LP377THR1-70G-01-MT may be filled with any or all bins contained as below.
All Luminous Flux –ΦV , VF & Dominant Wavelength –λD values shown and specified are at If=70mA.
* J+
Luminous Flux (ΦV)
L
K
J
620nm
637nm
Dominant Wavelength (λD)
Rank
J
K
L
Luminous Flux
3000-4200 mlm
3500-4800 mlm
4000-6100 mlm
* J+ indicates Luminous Flux is at J bin or above.
Forward Voltage (VF)
Rank
V4
V5
V6
V7
V8
Voltage
2.2-2.4V
2.4-2.6V
2.6-2.8V
2.8-3.0V
3.0-3.2 V
Important Notes:
1) All ranks will be included per delivery, rank ratio will be based on the Dices distribution.
2) No tolerance in the measurement of luminous flux.
3) Tolerance of measurement of dominant wavelength is ±1nm.
4) Tolerance of measurement of Vf is ±0.05 V.
5) Packaging methods are available for selection, please refer to PACKAGING STANDARD.
6) Please refer to LED LAMP RELIABILITY TEST STANDARD for reliability test conditions.
7) Please refer to APPLICATION NOTES for Application Notes.
3/4
Format #: COTCO-D-074
REV.3
Document No. SPE/LP377THR1-70G-01-MT
Rev. No.
02
Graphs
1. Cathode PAD Area (0.18 x 0.18 x 2inch2)
2. Height above nominal seating plane in inches(0.3inch)
Items
Signatures
Date
Prepared by
LiuZM
2005-09-15
Rev. No
Checked by
Aldosin
2005-09-15
02
Approved by
David
2005-09-15
FCN#
Revision History
Date
Change Description
2005-09-15 Correct FIG.6 from 120deg to 70deg.
FCN20050297
Data is subject to change without prior notice.
Copyright@2002 Cotco International Ltd.
4/4
Format #: COTCO-D-074
REV.3
Similar pages