Micross MIMMF400Y040DK1 400v 400a fred module rohs compliant Datasheet

MIMMF400Y040DK1
400V 400A
FRED Module
RoHS Compliant
PRODUCT FEATURES
Ultrafast Reverse Recovery Time
Soft Reverse Recovery Characteristics
Low Reverse Recovery Loss
Low Forward Voltage
High Surge Current Capability
Low Inductance Package
APPLICATIONS
Inversion Welder
Uninterruptible Power Supply (UPS)
Plating Power Supply
Ultrasonic Cleaner and Welder
Converter & Chopper
Power Factor Correction (PFC) Circuit
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
TC=25°C unless otherwise specified
Test Conditions
Values
Unit
VR
Maximum D.C. Reverse Voltage
400
V
VRRM
Maximum Repetitive Reverse Voltage
400
V
TC=125°C, Per Diode
200
A
TC=125°C, Per Moudle
400
A
TC=125°C, 20KHz, Per Moudle
300
A
RMS Forward Current
TC=125°C, Per Diode
282
A
Non-Repetitive Surge
1/2 Cycle , 50Hz, Sine
4000
A
Forward Current
1/2 Cycle , 60Hz, Sine
4500
A
TJ=45°C, t=10ms, 50Hz, Sine
80000
A2s
TJ=45°C, t=8.3ms, 60Hz, Sine
101250
A2s
2080
W
IF(AV)
IF(RMS)
IFSM
Average Forward Current
I2t
I2t (For Fusing)
PD
Power Dissipation
TJ
Junction Temperature
-40 to +150
°C
TSTG
Storage Temperature Range
-40 to +125
°C
Torque
Module-to-Sink
Recommended(M6)
3~4.7
N·m
Torque
Module Electrodes
Recommended(M6)
3~4.7
N·m
RθJC
Thermal Resistance
Junction-to-Case
0.06
°C /W
92
g
Weight
MIMMF400Y040DK1
ELECTRICAL CHARACTERISTICS
Symbol
Parameter
TC=25°C unless otherwise specified
Test Conditions
Min.
Typ.
Max.
Unit
VR=400V
--
--
1
mA
VR=400V, TJ=125°C
--
--
2
mA
IF=200A
--
1.1
1.35
V
IF=200A, TJ=125°C
--
1.0
1.25
V
IRM
Reverse Leakage Current
VF
Forward Voltage
trr
Reverse Recovery Time
IF=1A, VR=30V, diF/dt=-200A/μs
--
45
--
ns
trr
Reverse Recovery Time
VR=200V, IF=200A
--
135
--
ns
IRRM
Max. Reverse Recovery Current
diF/dt=-200A/μs, TJ=25°C
--
12
--
A
trr
Reverse Recovery Time
VR=200V, IF=200A
--
210
--
ns
IRRM
Max. Reverse Recovery Current
diF/dt=-200A/μs, TJ=125°C
--
20
--
A
600
500
500
400
400
TJ =125°C
trr (ns)
IF (A)
VR=200V
TJ =125°C
300
TJ =25°C
300
200
200
IF=400A
100 IF=200A
100
0
0
IF=100A
0
1
1.5
2.5
2
VF(V)
Figure1. Forward Voltage Drop vs Forward Current
100
0.5
200
VR=200V
TJ =125°C
5
4
60
IF=400A
IF=200A
40
IF=100A
20
Qrr (μc)
IRRM (A)
400
600
800
1000
diF/dt(A/μs)
Figure2. Reverse Recovery Time vs diF/dt
6
VR=200V
TJ =125°C
80
0
0
0
IF=400A
IF=200A
3
IF=100A
2
1
400
600
1000
800
diF/dt(A/μs)
Figure3. Reverse Recovery Current vs diF/dt
200
0
0
200
400
600
800
1000
diF/dt(A/μs)
Figure4. Reverse Recovery Charge vs diF/dt
MIMMF400Y040DK1
1.5
1
1.2
-1
10
ZthJC (K/W)
Kf
0.9
trr
0.6 IRRM
0.0
10-3
Qrr
0.3
0
10-2
25
50
100 125 150
75
TJ (°C)
Figure5. Dynamic Parameters vs Junction Temperature
-4
10
Duty
0.5
0.2
0.1
0.05
Single Pulse
-1
10-4
10-3
10-2
10
1
Rectangular Pulse Duration (seconds)
Figure6. Transient Thermal Impedance
Dimensions (mm)