Mean Well HLN-40H-20 40w single output switching power supply Datasheet

HLN-40H
40W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
IP64 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp location or outdoor application
3 years warranty
110
F
HLN-40H-12 A
M
M
SELV
IP64
A : IP64 rated. Output voltage and constant current level can be adjusted through internal potential meter.
B : IP64 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
SPECIFICATION
MODEL
HLN-40H-12
HLN-40H-15
12V
DC VOLTAGE
CONSTANT CURRENT REGION Note.4 7.2 ~12V
HLN-40H-54
15V
20V
24V
30V
48V
54V
9 ~ 15V
12 ~ 20V
14.4 ~ 24V
21.6 ~ 36V
25.2 ~ 42V
28.8 ~ 48V
32.4 ~ 54V
1.12A
0.96A
0.84A
0.75A
2A
1.67A
RATED POWER
40W
40W
40W
40.1W
40.2W
40.3W
40.3W
40.3W
40.5W
150mVp-p
150mVp-p
150mVp-p
200mVp-p
200mVp-p
300mVp-p
300mVp-p
300mVp-p
17 ~ 22V
22 ~ 27V
27 ~ 33V
33 ~ 40V
40 ~ 46V
44 ~ 53V
49 ~ 58V
Can be adjusted by internal potential meter or through output cable
CURRENT ADJ. RANGE
2 ~ 3.33A
1.6 ~ 2.67A
1.2 ~ 2A
1 ~ 1.67A
0.8 ~ 1.34A
0.67 ~ 1.12A 0.58 ~ 0.96A 0.5 ~ 0.84A
1.0%
1.0%
1.0%
0.45 ~ 0.75A
VOLTAGE TOLERANCE Note.3
2.5%
2.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.5%
1.0%
2.0%
Note.7 1500ms, 80ms / 115VAC at full load
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
VOLTAGE RANGE
16ms/230VAC
Note.5 90 ~ 305VAC
1.0%
1000ms, 80ms / 230VAC at full load
16ms/115VAC at full load
127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
87%
88%
87%
0.43A / 115VAC
0.24A / 230VAC
COLD START 70A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
OVER CURRENT
89%
88.5%
0.23A / 277VAC
89%
90%
90%
90%
54 ~ 63V
59 ~ 66V
<0.75mA / 277VAC
LEAKAGE CURRENT
Note.4
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
41 ~ 49V
12 ~ 21V
18 ~ 24V
23 ~ 30V
35 ~ 43V
48 ~ 58V
28 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
70
10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +50
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 40
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750, EN61347-1, EN61347-2-13 independent, IP64 approved ; Design refer to UL60950-1, TUV EN60950-1, EN60335-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
HLN-40H-48
42V
2.67A
HOLD UP TIME (Typ.)
OTHERS
HLN-40H-42
3.33A
SETUP, RISE TIME
EMC
HLN-40H-36
RATED CURRENT
LOAD REGULATION
SAFETY &
HLN-40H-30
36V
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V 13.5 ~ 17V
INPUT
HLN-40H-24
18 ~ 30V
1.34A
RIPPLE & NOISE (max.) Note.2 150mVp-p
OUTPUT
HLN-40H-20
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
336.5Khrs min. MIL-HDBK-217F (25 )
161*61.5*35mm (L*W*H)
0.35Kg;40pcs/15Kg/1.36CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:HLN-40H-SPEC 2011-06-03
HLN-40H
40W Single Output Switching Power Supply
Mechanical Specification
Case No.HLN-60A
series
Unit:mm
A Type:(HLN-40H-_A)
161
2-R2.5
35
+V(Red)
-V(Black)
21.25
SVT 18AWG 2C
SVT 18AWG 3C
6.26
35
T case: Max. Case Temperature.
2.3
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
T
case
61.5
300 20
300 20
20
21.25
6.26
IP64 rated. Output voltage and constant current level can be adjusted through internal potential meter.
(can access by removing the rubber stopper on the case).
B Type:(HLN-40H-_B)
161
2-R2.5
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
35
SVT 18AWG 4C
21.25
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
T
case
61.5
300 20
300 20
20
21.25
6.26
SVT 18AWG 3C
6.26
35
T case: Max. Case Temperature.
Block Diagram
fosc : 100KHz
I/P
EMI FILTER
&
RECTIFIERS
POWER
SWITCHING
PFC
CIRCUIT
RECTIFIERS
&
FILTER
+V
-V
DIM+
DIM(B Type)
O.L.P.
FG
O.T.P.
O.L.P.
PWM & PFC
CONTROL
DETECTION
CIRCUIT
O.V.P.
File Name:HLN-40H-SPEC 2011-06-03
HLN-40H
40W Single Output Switching Power Supply
Derating Curve
series
Static Characteristics
100
100
90
80
80
230VAC
Input only
70
LOAD (%)
LOAD (%)
60
40
20
-40
-25
-10
0
15
30
40
50
60
(HORIZONTAL)
AMBIENT TEMPERATURE ( )
60
50
40
90
100
125
135
145
155 165
175
180
200
230
305
INPUT VOLTAGE (V) 60Hz
Power Factor Characteristic
Constant Current Mode
1
0 .9 9
0 .9 8
0 .9 7
0 .9 6
0 .9 5
PF
0 .9 4
0 .9 3
277VAC
0 .9 2
230VAC
0 .9 1
110VAC
0 .9
0 .8 9
0 .8 8
0 .8 7
0 .8 6
0 .8 5
50%
60%
70%
80%
90%
100%
(40W)
LOAD
EFFICIENCY vs LOAD (48V Model)
HLN-40H series possess superior working efficiency that up to 90% can be reached in field applications.
92
90
EFFICIENCY (%)
88
86
84
82
277VAC
80
230VAC
78
110VAC
76
74
72
70
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
LOAD
File Name:HLN-40H-SPEC 2011-06-03
HLN-40H
40W Single Output Switching Power Supply
series
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
(B)
Constant
Current area
100
Vo(%)
(A) Constant
Voltage area
60
(max.)
(C)
Hiccup
Protection
50
Io (%)
95
Typical LED power supply I-V curve
DIMMING OPERATION(for B-type only)
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
HLN-40H
B Type
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
Vo and Io can not be adjusted (B type)
Built-in 3 in 1 dimming function, IP64 rated. Output constant current level can be adjusted through output cable by connecting a resistance or
1 ~ 10Vdc or 10V PWM signal between DIM+ and DIM-.
Please DO NOT connect "DIM-" to "-V".
Reference resistance value for output current adjustment (Typical)
10K
30K
40K
50K
70K
80K
90K
Single driver
100K
20K
60K
Resistance
Multiple
drivers
value
(N=driver quantity for synchronized 10K
/N 20K /N 30K /N 40K /N 50K /N 60K /N 70K /N 80K /N 90K /N 100K /N
dimming operation)
Percentage of rated current
10%
20%
30%
40%
OPEN
-----
50%
60%
70%
80%
90%
100%
95%~105%
1 ~ 10V dimming function for output current adjustment (Typical)
Dimming value
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
OPEN
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95%~105%
10V PWM signal for output current adjustment (Typical): Frequency range:100Hz ~ 3KHz
Duty value
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
OPEN
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95%~105%
File Name:HLN-40H-SPEC 2011-06-03
HLN-40H
40W Single Output Switching Power Supply
series
Using the built-in dimming function on B-type model can't turn the lighting fixture totally dark. Please refer to the connection method below to
achieve 0% brightness of the lighting fixture connecting to the LED power supply unit.
Dimming connection diagram for turning the lighting fixture ON/OFF :
N
FG
L
Switch
Relay
Adjuster
0~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
Green/
Yellow
Brown
Blue
AC/L
HLN-40H
B Type
AC/N
DIM+
DIMV(-)
V(+)
Blue
White
Black
Red
LED Lighting Fixture
Using a switch and relay can turn ON/OFF the lighting fixture.
1.Output constant current level can be adjusted through output cable by connecting a resistor or 1~10Vdc or 10V PWM signal between DIM+ and DIM-.
2.The LED lighting fixture can be turned ON/OFF by the switch.
File Name:HLN-40H-SPEC 2011-06-03
Similar pages