Bourns MF-RX012250-T Telecom ptc resettable fus Datasheet

PL
IA
NT
CO
M
*R
oH
S
RX0
240012
1K
Features
Applications
■ Radial leaded devices
■ Customer Premise Equipment (CPE)
■ Fast tripping resettable PTCs
■ Central Office / Telecom Centers (CO)
■ Binned and sorted narrow resistance
■ Access equipment
ranges available
■ RoHS compliant*
■ Agency recognition:
MF-RX/250 Series - Telecom PTC Resettable Fuses
Electrical Characteristics
Model
Max.
Operating
Voltage
(Vdc)
MF-RX012/250
MF-RX012/250-A
MF-RX012/250-C
MF-RX012/250-F
MF-RX012/250-1
MF-RX012/250-2
MF-RX012/250-T
MF-RX012/250U
MF-RX014/250
MF-RX014/250-A
MF-RX014/250-B
MF-RX014/250-T
MF-RX014/250U
MF-RX018/250
MF-RX018/250U
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
Max. Interrupt
Ratings
Volts
(Vrms)
Max.
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Hold Current
Amps
(A)
Max.
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
10.0
10.0
Amps
at 23 °C
IH
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.145
0.145
0.145
0.145
0.145
0.18
0.18
Initial Resistance
Ohms
at 23 °C
Min.
4.0
7.0
5.5
6.0
6.0
8.0
7.0
6.0
3.0
3.0
4.5
5.4
3.5
0.8
0.8
Ohms
at 23 °C
Max.
8.0
9.0
7.5
10.5
9.0
10.5
12.0
10.0
6.0
5.5
6.0
7.5
6.5
2.0
2.0
One Hour
Post-Trip
Resistance
Ohms
at 23 °C
Max.
16.0
16.0
14.0
16.0
16.0
16.0
16.0
16.0
14.0
12.0
14.0
14.0
12.0
4.0
4.0
“U” suffix indicates product without insulation coating.
Environmental Characteristics
Operating/Storage Temperature ........................... -40 °C to +85 °C
Maximum Device Surface Temperature
in Tripped State ................................................ 125 °C
Passive Aging ....................................................... +85 °C, 1000 hours.............................................. ±15 % typical resistance change
.......................................................................... +60°C, 1000 hours................................................ ±15 % typical resistance change
Humidity Aging ..................................................... +85 °C, 85 % R.H. 500 hours ............................... ±15 % typical resistance change
Thermal Shock ..................................................... MIL-STD-202F, Method 107G, ............................. ±10 % typical resistance change
.......................................................................... +125 °C to -55 °C,10 times .................................. ±15 % typical resistance change
Solvent Resistance ............................................... MIL-STD-202, Method 215B ................................ No change
Lead Solerability ................................................... ANSI/J-STD-002 ................................................... >95 % coverage
Flammability ......................................................... IEC 695-2-2 .......................................................... No Flame for 60 secs.
Vibration ............................................................... MIL-STD-883C, Method 2007.1, Condition A ...... ±5 % typical resistance change
Test Procedures And Requirements For Model MF-RX/250 Series
Test
Test Conditions
Accept/Reject Criteria
Visual/Mech. .................................................... Verify dimensions and materials ...................... Per MF physical description
Resistance ....................................................... In still air @ 23 °C ............................................. Rmin ≤ R ≤ Rmax
Time to Trip...................................................... 5 times Ihold, Vmax, 23 °C .............................. T ≤ max. time to trip (seconds)
Hold Current .................................................... 30 min. at Ihold ................................................ No trip
Trip Cycle Life .................................................. Vmax, Imax, 100 cycles ................................... No arcing or burning
Trip Endurance ................................................ Vmax, 48 hours ................................................ No arcing or burning
UL File Number ............................................... E 174545S
CSA File Number ............................................. CA 110338
TÜV File Number ............................................. R2057213
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
Additional Features
■ Ability to withstand AC power cross conditions
■ Assists equipment with meeting ITU-T K.20/K.21/K.45
■ Assists equipment with meeting Telcordia GR-1089-C Intrabuilding
MF-RX/250 Series - Telecom PTC Resettable Fuses
Thermal Derating Chart - Ihold (Amps)
Ambient Operating Temperature
Model
-40 ºC
-20 ºC
0 ºC
23 ºC
40 ºC
50 ºC
60 ºC
70 ºC
85 ºC
MF-RX012/250
0.186
0.165
0.143
0.120
0.099
0.088
0.077
0.066
0.050
MF-RX014/250
0.225
0.199
0.172
0.145
0.119
0.106
0.093
0.080
0.060
MF-RX018/250
0.269
0.240
0.211
0.180
0.153
0.138
0.123
0.109
0.087
Itrip is approximately two times Ihold.
Product Dimensions
A
Max.
6.5
(0.256)
6.0
(0.236)
6.5
(0.256)
6.0
(0.236)
11.0
(0.433)
10.4
(0.409)
Model
MF-RX012/250
MF-RX012/250U
MF-RX014/250
MF-RX014/250U
MF-RX018/250
MF-RX018/250U
Packaging options: BULK: 500 pcs. per bag.
B
Max.
11.0
(0.433)
10.0
(0.394)
11.0
(0.433)
10.0
(0.394)
13.6
(0.535)
12.6
(0.496)
C
Nom.
5.1 ± 0.7
(0.201 ± 0.028)
5.1 ± 0.7
(0.201 ± 0.028)
5.1 ± 0.7
(0.201 ± 0.028)
5.1 ± 0.7
(0.201 ± 0.028)
5.1 ± 0.7
(0.201 ± 0.028)
5.1 ± 0.7
(0.201 ± 0.028)
D
Min.
4.7
(0.185)
4.7
(0.185)
4.7
(0.185)
4.7
(0.185)
4.7
(0.185)
4.7
(0.185)
E
Max.
4.6
(0.181)
3.8
(0.150)
4.6
(0.181)
3.8
(0.150)
4.6
(0.181)
3.8
(0.150)
Physical Characteristics
Lead Dia.
Style
Material
0.65
1
Sn/Cu
(0.026)
0.65
2
Sn/Cu
(0.026)
0.65
1
Sn/Cu
(0.026)
0.65
2
Sn/Cu
(0.026)
0.65
1
Sn/Cu
(0.026)
0.65
2
Sn/Cu
(0.026)
TAPE & REEL: 1500 pcs. per reel (available binned).
DIMENSIONS:
Style 1
Style 2
A
Typical Part Marking
A
E
E
B
B
Represents total content. Layout may vary.
MANUFACTURER'S
TRADEMARK
DATE CODE
(FIRST DIGIT =
LAST DIGIT OF YEAR;
SECOND DIGIT = MONTH,
AS FOLLOWS:
1-9 = JAN-SEPT
X,Y,Z = OCT-DEC)
D
MM
(INCHES)
PART
IDENTIFICATION
RX012
24001K
BATCH/LOCATION
(3 DIGITS = BATCH CODE;
K = KOREA
S = CHINA)
C
NOTE: UNCOATED PARTS HAVE NO PART MARKING.
MARKING IS ON LABEL ONLY.
D
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
C
MF-RX/250 Series - Telecom PTC Resettable Fuses
How to Order
Typical Time to Trip at 23 ˚C
MF - RX 012/250 U - A 5 - 2
1000
®
Multifuse
Product
Designator
Hold Current, Ihold
008-018 (0.08-0.18 Amps)
Max. Interrupt Voltage, V
250 (250 Volts)
Telecom Options
U = Uncoated (radial parts only)
Resistance Sorted
Narrow resistance ranges - see
Resistance Options chart
100
Time to Trip (Seconds)
Series
RX = Radial Leaded
Component
10
MF-RX018/250, MF-RX018/250U
1
MF-RX014/250 & MF-RX014/250U
MF-RX012/250 & MF-RX012/250U
0.10
Resistance Bins of 0.5 ohms
05 = 0.5 ohm binned parts (epoxy coated)
5 = 0.5 ohm binned parts (uncoated)
Packaging Options
- 0 = Bulk Packaging
- 2 = Tape and Reel* (available with binned
option)
0.01
0
0.2 0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0 2.2
2.4
2.6
2.8 3.0
Fault Current (Amps)
*Packaged per EIA486-B
Resistance Options
Model
Initial Resistance
Values
R1max
Ohms @ 23 ° C
Ohms @ 23 ° C
Bin
Min.
Max.
Max.
MF-RX012/250
4.0
8.0
16.0
0.5
MF-RX012/250-A05
7.0
9.0
16.0
0.5
MF-RX012/250-C05
5.5
7.5
14.0
0.5
MF-RX012/250-F05
6.0
10.5
16.0
0.5
MF-RX012/250-105
6.0
9.0
16.0
0.5
MF-RX012/250-205
8.0
10.5
16.0
0.5
MF-RX012/250-T05
7.0
12.0
16.0
0.5
MF-RX012/250U
6.0
10.0
16.0
0.5
MF-RX014/250
3.0
6.0
14.0
0.5
MF-RX014/250-A05
3.0
5.5
12.0
0.5
MF-RX014/250-B05
4.5
6.0
14.0
0.5
MF-RX014/250U
3.5
6.5
12.0
0.5
MF-RX/250, REV. J, 05/11
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72 & MF-RX/250 Series
Tape and Reel Specifications
Devices taped using EIA468–B/IEC286-2 standards. See table below and Figures 1 and 2 for details.
IEC
Mark
EIA
Mark
Carrier tape width
W
W
Hold down tape width
W0
W4
Dimension Description
Hold down tape
Top distance between tape edges
Dimensions
Dimensions
Tolerance
18
-0.5/+1.0
(.709)
(-0.02/+.039)
11
min.
(.433)
No protrusion
W2
W6
Sprocket hole position
W1
W5
Sprocket hole diameter
D0
D0
Abscissa to plane (straight lead)
H
H
Abscissa to plane (kinked lead)
H0
H0
Abscissa to top (straight lead)
H1
H1
Abscissa to top (kinked lead)
H1
H1
Overall width w/lead protrusion (straight lead)
C1
Overall width w/lead protrusion (kinked lead)
C1
Overall width w/o lead protrusion (straight lead)
C2
Overall width w/o lead protrusion (kinked lead)
C2
3
(.118)
9
(.354)
4
(.157)
18.5
(.728)
16
(.63)
38.0
(1.496)
32.2
(1.268)
55.0
(2.165)
43.2
(1.7)
54.0
(2.126)
42.5
(1.673)
1.0
(.039)
11
(.433)
Lead protrusion
I1
L1
Protrusion of cutout
L
L
Protrusion beyond hold-down tape
I2
I2
Not specified
Sprocket hole pitch
P0
P0
12.7
(0.5)
Pitch tolerance
20 consecutive
max.
-0.5/+0.75
(-0.02/+0.03)
±0.2
(±.0078)
±3.0
(±.118)
±0.5
(±.02)
max.
max.
max.
max.
max.
max.
max.
max.
±0.3
(±.012)
±1
(±.039)
Device pitch: MF-R005–MF-R160, MF-R/90,
MF-RX110/72–MF-RX185/72
12.7
(0.5)
±0.3
(±.012)
Device pitch: MF-R185–MF-R400, MF-RX110–MF-RX375
MF-R/600, MF-RX250/72–MF-RX375/72
25.4
(1.0)
±0.6
(±.024)
0.9
(.035)
max.
Tape thickness
t
t
Tape thickness with splice: MF-R010–MF-R160,
MF-RX110/72–MF-RX185/72
t1
1.5
(.059)
max.
Tape thickness with splice: MF-R250–MF-R1100,
MF-RX110–MF-RX375, MF-R/90, MF-RX250/72-MF-RX375/72
t1
2.3
(.091)
max.
Splice sprocket hole alignment
0
Body lateral deviation
Δh
Δh
0
Body tape plane deviation
Δp
Δp
0
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
±0.3
(±.012)
±1.0
(±.039)
±1.3
(±.051)
DIMENSIONS:
MM
(INCHES)
MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72 & MF-RX/250 Series
Tape and Reel Specifications
IEC
Mark
EIA
Mark
Lead spacing: MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72
F
F
Lead spacing: MF-RX/250
F
F
Reel width
w
W2
Reel diameter
d
a
W1
h
Arbor hole diameter
f
c
Core diameter: MF-R, MF-RX, MF-R/90
h
n
Core diameter: MF-RX/250, MF-R/600
h
n
Dimension Description
Space between flanges less device
Dimensions
Dimensions
Tolerance
5.08
±0.2
(0.2)
(±0.008)
5.08
-0.5/+0.6
(0.2)
(-.020/+.024)
56.0
max.
(2.205)
370.0
max.
(14.57)
4.75
±3.25
(.187)
(±.128)
26.0
±12.0
(1.024)
(±.472)
80
max.
(3.15)
91
max.
(3.58)
56
372
372
max.
(2.2) (14.6) (14.6)
67
372
362
max.
(2.64) (14.6) (14.25)
64
372
362
max.
(2.52) (14.6) (14.25)
Box: MF-R, MF-RX, MF-R/90
Box: MF-RX/250
Box: MF-R/600
Consecutive missing places: MF-R, MF-RX, MF-R/90
3
Consecutive missing places: MF-RX/250, MF-R/600
none
Empty places per reel: MF-R, MF-RX, MF-R/90
Not specified
Empty places per reel: MF-RX/250, MF-R/600
0.1 %
max.
Taped Component Dimensions - Figure 1
h
p
h
p
Reference plane
P1
H1
A
L
I2
H1
F
H
H0
B
W0
I1
P0
W1
W
D0
User direction of feed
DIMENSIONS:
Cross section A - B
Reel Dimensions - Figure 2
MM
(INCHES)
t
Reel
h
d
User
direction
of
feed
Upper side
Tape
Lower side
f
h
w
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.