ATMEL AT29C040A-12JU 4-megabit (512k x 8) 5-volt only 256-byte sector flash memory Datasheet

Features
• Fast Read Access Time – 90 ns
• 5-volt Only Reprogramming
• Sector Program Operation
•
•
•
•
•
•
•
•
•
– Single Cycle Reprogram (Erase and Program)
– 2048 Sectors (256 Bytes/Sector)
– Internal Address and Data Latches for 256 Bytes
Internal Program Control and Timer
Hardware and Software Data Protection
Two 16K Bytes Boot Blocks with Lockout
Fast Sector Program Cycle Time – 10 ms
DATA Polling for End of Program Detection
Low Power Dissipation
– 40 mA Active Current
– 100 µA CMOS Standby Current
Typical Endurance > 10,000 Cycles
Single 5V ± 10% Supply
Green (Pb/Halide-free) Packaging Option
1. Description
4-megabit
(512K x 8)
5-volt Only
256-byte Sector
Flash Memory
AT29C040A
The AT29C040A is a 5-volt only in-system Flash Programmable and Erasable Read
Only Memory (PEROM). Its 4 megabits of memory is organized as 524,288 words by
8 bits. Manufactured with Atmel’s advanced nonvolatile CMOS EEPROM technology,
the device offers access times up to 90 ns, and a low 220 mW power dissipation.
When the device is deselected, the CMOS standby current is less than 100 µA. The
device endurance is such that any sector can typically be written to in excess of
10,000 times. The programming algorithm is compatible with other devices in Atmel’s
5-volt only Flash family.
To allow for simple in-system reprogrammability, the AT29C040A does not require
high input voltages for programming. Five-volt-only commands determine the operation of the device. Reading data out of the device is similar to reading from an
EPROM. Reprogramming the AT29C040A is performed on a sector basis; 256 bytes
of data are loaded into the device and then simultaneously programmed.
During a reprogram cycle, the address locations and 256 bytes of data are internally
latched, freeing the address and data bus for other operations. Following the initiation
of a program cycle, the device will automatically erase the sector and then program
the latched data using an internal control timer. The end of a program cycle can be
detected by DATA polling of I/O7. Once the end of a program cycle has been
detected, a new access for a read or program can begin.
0333L–FLASH–9/08
2. Pin Configurations
Function
A0 - A18
Addresses
CE
Chip Enable
OE
Output Enable
WE
Write Enable
I/O0 - I/O7
Data Inputs/Outputs
NC
No Connect
32-lead PLCC Top View
29
28
27
26
25
24
23
22
21
14
15
16
17
18
19
20
5
6
7
8
9
10
11
12
13
A14
A13
A8
A9
A11
OE
A10
CE
I/O7
I/O1
I/O2
GND
I/O3
I/O4
I/O5
I/O6
A7
A6
A5
A4
A3
A2
A1
A0
I/O0
4
3
2
1
32
31
30
A12
A15
A16
A18
VCC
WE
A17
2.1
Pin Name
2.2
32-lead TSOP Top View – Type 1
A11
A9
A8
A13
A14
A17
WE
VCC
A18
A16
A15
A12
A7
A6
A5
A4
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
OE
A10
CE
I/O7
I/O6
I/O5
I/O4
I/O3
GND
I/O2
I/O1
I/O0
A0
A1
A2
A3
AT29C040A
0333L–FLASH–9/08
AT29C040A
3. Block Diagram
4. Device Operation
4.1
Read
The AT29C040A is accessed like an EPROM. When CE and OE are low and WE is high, the
data stored at the memory location determined by the address pins is asserted on the outputs.
The outputs are put in the high impedance state whenever CE or OE is high. This dual-line control gives designers flexibility in preventing bus contention.
4.2
Byte Load
Byte loads are used to enter the 256 bytes of a sector to be programmed or the software codes
for data protection. A byte load is performed by applying a low pulse on the WE or CE input with
CE or WE low (respectively) and OE high. The address is latched on the falling edge of CE or
WE, whichever occurs last. The data is latched by the first rising edge of CE or WE.
4.3
Program
The device is reprogrammed on a sector basis. If a byte of data within a sector is to be changed,
data for the entire sector must be loaded into the device. Any byte that is not loaded during the
programming of its sector will be erased to read FFH. Once the bytes of a sector are loaded into
the device, they are simultaneously programmed during the internal programming period. After
the first data byte has been loaded into the device, successive bytes are entered in the same
manner. Each new byte to be programmed must have its high to low transition on WE (or CE)
within 150 μs of the low to high transition of WE (or CE) of the preceding byte. If a high to low
transition is not detected within 150 μs of the last low to high transition, the load period will end
and the internal programming period will start. A8 to A18 specify the sector address. The sector
address must be valid during each high to low transition of WE (or CE). A0 to A7 specify the byte
address within the sector. The bytes may be loaded in any order; sequential loading is not
required. Once a programming operation has been initiated, and for the duration of tWC, a read
operation will effectively be a polling operation.
4.4
Software Data Protection
A software controlled data protection feature is available on the AT29C040A. Once the software
protection is enabled a software algorithm must be issued to the device before a program may
3
0333L–FLASH–9/08
be performed. The software protection feature may be enabled or disabled by the user; when
shipped from Atmel, the software data protection feature is disabled. To enable the software
data protection, a series of three program commands to specific addresses with specific data
must be performed. After the software data protection is enabled the same three program commands must begin each program cycle in order for the programs to occur. All software program
commands must obey the sector program timing specifications. The SDP feature protects all
sectors, not just a single sector. Once set, the software data protection feature remains active
unless its disable command is issued. Power transitions will not reset the software data protection feature, however the software feature will guard against inadvertent program cycles during
power transitions.
After setting SDP, any attempt to write to the device without the three-byte command sequence
will start the internal write timers. No data will be written to the device; however, for the duration
of tWC, a read operation will effectively be a polling operation.
After the software data protection’s 3-byte command code is given, a byte load is performed by
applying a low pulse on the WE or CE input with CE or WE low (respectively) and OE high. The
address is latched on the falling edge of CE or WE, whichever occurs last. The data is latched by
the first rising edge of CE or WE. The 256 bytes of data must be loaded into each sector by the
same procedure as outlined in the program section under device operation.
4.5
Hardware Data Protection
Hardware features protect against inadvertent programs to the AT29C040A in the following
ways: (a) VCC sense – if VCC is below 3.8V (typical), the program function is inhibited; (b) VCC
power on delay – once VCC has reached the VCC sense level, the device will automatically time
out 5 ms (typical) before programming; (c) Program inhibit – holding any one of OE low, CE high
or WE high inhibits program cycles; and (d) Noise filter – pulses of less than 15 ns (typical) on
the WE or CE inputs will not initiate a program cycle.
4.6
Product Identification
The product identification mode identifies the device and manufacturer as Atmel. It may be
accessed by hardware or software operation. The hardware operation mode can be used by an
external programmer to identify the correct programming algorithm for the Atmel product. In
addition, users may wish to use the software product identification mode to identify the part
(i.e. using the device code), and have the system software use the appropriate sector size for
program operations. In this manner, the user can have a common board design for 256K to
4-megabit densities and, with each density’s sector size in a memory map, have the system software apply the appropriate sector size.
For details, see Operating Modes (for hardware operation) or Software Product Identification.
The manufacturer and device code is the same for both modes.
4.7
DATA Polling
The AT29C040A features DATA polling to indicate the end of a program cycle. During a program cycle an attempted read of the last byte loaded will result in the complement of the loaded
data on I/O7. Once the program cycle has been completed, true data is valid on all outputs and
the next cycle may begin. DATA polling may begin at any time during the program cycle.
4.8
Toggle Bit
In addition to DATA polling the AT29C040A provides another method for determining the end of
a program or erase cycle. During a program or erase operation, successive attempts to read
4
AT29C040A
0333L–FLASH–9/08
AT29C040A
data from the device will result in I/O6 toggling between one and zero. Once the program cycle
has completed, I/O6 will stop toggling and valid data will be read. Examining the toggle bit may
begin at any time during a program cycle.
4.9
Optional Chip Erase Mode
The entire device can be erased by using a 6-byte software code. Please see Software Chip
Erase application note for details.
4.10
Boot Block Programming Lockout
The AT29C040A has two designated memory blocks that have a programming lockout feature.
This feature prevents programming of data in the designated block once the feature has been
enabled. Each of these blocks consists of 16K bytes; the programming lockout feature can be
set independently for either block. While the lockout feature does not have to be activated, it can
be activated for either or both blocks.
These two 16K memory sections are referred to as boot blocks. Secure code which will bring up
a system can be contained in a boot block. The AT29C040A blocks are located in the first 16K
bytes of memory and the last 16K bytes of memory. The boot block programming lockout feature
can therefore support systems that boot from the lower addresses of memory or the higher
addresses. Once the programming lockout feature has been activated, the data in that block can
no longer be erased or programmed; data in other memory locations can still be changed
through the regular programming methods. To activate the lockout feature, a series of seven
program commands to specific addresses with specific data must be performed. Please see
Boot Block Lockout Feature Enable Algorithm.
If the boot block lockout feature has been activated on either block, the chip erase function will
be disabled.
4.10.1
Boot Block Lockout Detection
A software method is available to determine whether programming of either boot block section is
locked out. See Software Product Identification Entry and Exit sections. When the device is in
the software product identification mode, a read from location 00002H will show if programming
the lower address boot block is locked out while reading location 7FFF2H will do so for the upper
boot block. If the data is FE, the corresponding block can be programmed; if the data is FF, the
program lockout feature has been activated and the corresponding block cannot be programmed. The software product identification exit mode should be used to return to standard
operation.
5. Absolute Maximum Ratings*
Temperature Under Bias............................... -55° C to +125° C
Storage Temperature .................................... -65° C to +150° C
All Input Voltages (including NC Pins)
with Respect to Ground ...................................-0.6V to +6.25V
All Output Voltages
with Respect to Ground .............................-0.6V to VCC + 0.6V
*NOTICE:
Stresses beyond those listed under “Absolute
Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and
functional operation of the device at these or any
other conditions beyond those indicated in the
operational sections of this specification is not
implied. Exposure to absolute maximum rating
conditions for extended periods may affect
device reliability.
Voltage on OE
with Respect to Ground ...................................-0.6V to +13.5V
5
0333L–FLASH–9/08
6. DC and AC Operating Range
Operating Temperature (Case)
Industrial
VCC Power Supply
AT29C040A-90
AT29C040A-12
-40° C - 85° C
-40° C - 85° C
5V ± 10%
5V ± 10%
7. Operating Modes
Mode
Read
Program
(2)
Standby/Write Inhibit
CE
OE
WE
Ai
I/O
VIL
VIL
VIH
Ai
DOUT
VIL
VIH
VIL
Ai
DIN
X
High Z
(1)
VIH
X
X
Program Inhibit
X
X
VIH
Program Inhibit
X
VIL
X
Output Disable
X
VIH
X
VIL
VIL
VIH
High Z
Product Identification
Hardware
A1 - A18 = VIL, A9 = VH,(3) A0 = VIL
Manufacturer Code(4)
A1 - A18 = VIL, A9 = VH,(3) A0 = VIH
Device Code(4)
A0 = VIL
Manufacturer Code(4)
A0 = VIH
Device Code(4)
Software(5)
Notes:
1.
2.
3.
4.
5.
X can be VIL or VIH.
Refer to AC Programming Waveforms.
VH = 12.0V ± 0.5V.
Manufacturer Code: 1F, Device Code: A4.
See details under Software Product Identification Entry/Exit.
8. DC Characteristics
Symbol
Parameter
Condition
ILI
Input Load Current
ILO
Max
Units
VIN = 0V to VCC
10
µA
Output Leakage Current
VI/O = 0V to VCC
10
µA
ISB1
VCC Standby Current CMOS
CE = VCC - 0.3V to VCC
300
µA
ISB2
VCC Standby Current TTL
CE = 2.0V to VCC
3
mA
ICC
VCC Active Current
f = 5 MHz; IOUT = 0 mA
40
mA
VIL
Input Low Voltage
0.8
V
VIH
Input High Voltage
VOL
Output Low Voltage
IOL = 2.1 mA
VOH1
Output High Voltage
IOH = -400 µA
2.4
V
VOH2
Output High Voltage CMOS
IOH = -100 µA; VCC = 4.5V
4.2
V
6
Min
2.0
V
0.45
V
AT29C040A
0333L–FLASH–9/08
AT29C040A
9. AC Read Characteristics
AT29C040A-90
Symbol
Parameter
Min
Max
tACC
Address to Output Delay
tCE(1)
CE to Output Delay
tOE(2)
OE to Output Delay
0
40
tDF(3)(4)
CE or OE to Output Float
0
25
tOH
Output Hold from OE, CE or Address, whichever
occurred first
0
AT29C040A-12
Min
Max
Units
90
120
ns
90
120
ns
0
50
ns
0
30
ns
0
ns
10. AC Read Waveforms(1)(2)(3)(4)
Notes:
1. CE may be delayed up to tACC - tCE after the address transition without impact on tACC.
2. OE may be delayed up to tCE - tOE after the falling edge of CE without impact on tCE or by tACC - tOE after an address change
without impact on tACC.
3. tDF is specified from OE or CE whichever occurs first (CL = 5 pF).
4. This parameter is characterized and is not 100% tested.
7
0333L–FLASH–9/08
11. Input Test Waveforms and Measurement Level
tR, tF < 5 ns
12. Output Test Load
13. Pin Capacitance
f = 1 MHz, T = 25°C(1)
Symbol
Typ
Max
Units
Conditions
CIN
4
6
pF
VIN = 0V
COUT
8
12
pF
VOUT = 0V
Note:
8
1. This parameter is characterized and is not 100% tested.
AT29C040A
0333L–FLASH–9/08
AT29C040A
14. AC Byte Load Characteristics
Symbol
Parameter
Min
Max
Units
tAS, tOES
Address, OE Setup Time
10
ns
tAH
Address Hold Time
50
ns
tCS
Chip Select Setup Time
0
ns
tCH
Chip Select Hold Time
0
ns
tWP
Write Pulse Width (WE or CE)
90
ns
tDS
Data Setup Time
50
ns
tDH, tOEH
Data, OE Hold Time
10
ns
tWPH
Write Pulse Width High
100
ns
15. AC Byte Load Waveforms(1)
15.1
WE Controlled
15.2
CE Controlled
Note:
1. A complete sector (256 bytes) should be loaded using the waveforms shown in these byte load waveform diagrams.
9
0333L–FLASH–9/08
16. Program Cycle Characteristics
Symbol
Parameter
Min
Max
Units
tWC
Write Cycle Time
10
ms
tAS
Address Setup Time
10
ns
tAH
Address Hold Time
50
ns
tDS
Data Setup Time
50
ns
tDH
Data Hold Time
10
ns
tWP
Write Pulse Width
90
ns
tBLC
Byte Load Cycle Time
tWPH
Write Pulse Width High
150
100
µs
ns
17. Program Cycle Waveforms(1)(2)(3)
Notes:
10
1. A8 through A18 must specify the sector address during each high to low transition of WE (or CE).
2. OE must be high only when WE and CE are both low.
3. All bytes that are not loaded within the sector being programmed will be indeterminate.
AT29C040A
0333L–FLASH–9/08
AT29C040A
18. Software Data Protection
Enable Algorithm(1)
19. Software Data Protection
Disable Algorithm(1)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA A0
TO
ADDRESS 5555
LOAD DATA
TO
SECTOR (256 BYTES)(4)
LOAD DATA 80
TO
ADDRESS 5555
WRITES ENABLED
ENTER DATA
PROTECT STATE(2)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
Notes:
1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. Data Protect state will be activated at end of program
cycle.
3. Data Protect state will be deactivated at end of
program period.
4. 256 bytes of data MUST BE loaded.
LOAD DATA 20
TO
ADDRESS 5555
EXIT DATA
PROTECT STATE(3)
LOAD DATA
TO
SECTOR (256 BYTES)(4)
20. Software Protected Program Cycle Waveform(1)(2)(3)
Notes:
1. A8 through A18 must specify the sector address during each high to low transition of WE (or CE) after the software code has
been entered.
2. OE must be high when WE and CE are both low.
3. All bytes that are not loaded within the sector being programmed will be indeterminate.
11
0333L–FLASH–9/08
21. Data Polling Characteristics(1)
Symbol
Parameter
tDH
Data Hold Time
tOEH
OE Hold Time
Typ
Max
ns
10
ns
OE to Output Delay
Write Recovery Time
tWR
Units
10
(2)
tOE
Notes:
Min
ns
0
ns
1. These parameters are characterized and not 100% tested.
2. See tOE spec in AC Read Characteristics.
22. Data Polling Waveforms
23. Toggle Bit Characteristics(1)
Symbol
Parameter
tDH
Data Hold Time
tOEH
OE Hold Time
Min
OE to Output Delay
tOEHP
OE High Pulse
tWR
Write Recovery Time
Notes:
Max
Units
10
ns
10
ns
(2)
tOE
Typ
ns
150
ns
0
ns
1. These parameters are characterized and not 100% tested.
2. See tOE spec in AC Read Characteristics.
24. Toggle Bit Waveforms(1)(2)(3)
Notes:
12
1. Toggling either OE or CE or both OE and CE will operate toggle bit. The tOEHP specification must be met by the toggling
input(s).
2. Beginning and ending state of I/O6 will vary.
3. Any address location may be used but the address should not vary.
AT29C040A
0333L–FLASH–9/08
AT29C040A
25. Software Product Identification
Entry(1)
27. Boot Block Lockout
Feature Enable Algorithm(1)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 90
TO
ADDRESS 5555
LOAD DATA 80
TO
ADDRESS 5555
PAUSE 10 mS
LOAD DATA AA
TO
ADDRESS 5555
ENTER PRODUCT
IDENTIFICATION
MODE(2)(3)(5)
LOAD DATA 55
TO
ADDRESS 2AAA
26. Software Product Identification
Exit(1)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 40
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA F0
TO
ADDRESS 5555
Notes:
PAUSE 10 mS
Notes:
EXIT PRODUCT
IDENTIFICATION
MODE(4)
LOAD DATA 00
TO
ADDRESS 00000H(2)
LOAD DATA FF
TO
ADDRESS 7FFFFH(3)
PAUSE 10 mS
PAUSE 10 mS
1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. Lockout feature set on lower address boot block.
3. Lockout feature set on higher address boot block.
1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. A1 - A18 = VIL.
Manufacturer Code is read for A0 = VIL;
Device Code is read for A0 = VIH.
3. The device does not remain in identification mode if
powered down.
4. The device returns to standard operation mode.
5. Manufacturer Code is 1F. The Device Code is A4.
13
0333L–FLASH–9/08
28. Ordering Information
28.1
tACC
(ns)
90
120
Green Package Option (Pb/Halide-free)
ICC (mA)
Active
Standby
40
40
Ordering Code
Package
0.3
AT29C040A-90JU
AT29C040A-90TU
32J
32T
0.3
AT29C040A-12JU
AT29C040A-12TU
32J
32T
Operation Range
Industrial
(-40° to 85° C)
Package Type
32J
32-lead, Plastic J-leaded Chip Carrier (PLCC)
32T
32-lead, Thin Small Outline Package (TSOP)
14
AT29C040A
0333L–FLASH–9/08
AT29C040A
29. Packaging Information
29.1
32J – PLCC
1.14(0.045) X 45˚
PIN NO. 1
IDENTIFIER
1.14(0.045) X 45˚
0.318(0.0125)
0.191(0.0075)
E1
E
E2
B1
B
e
A2
D1
A1
D
A
0.51(0.020)MAX
45˚ MAX (3X)
COMMON DIMENSIONS
(Unit of Measure = mm)
D2
Notes:
1. This package conforms to JEDEC reference MS-016, Variation AE.
2. Dimensions D1 and E1 do not include mold protrusion.
Allowable protrusion is .010"(0.254 mm) per side. Dimension D1
and E1 include mold mismatch and are measured at the extreme
material condition at the upper or lower parting line.
3. Lead coplanarity is 0.004" (0.102 mm) maximum.
SYMBOL
MIN
NOM
MAX
A
3.175
–
3.556
A1
1.524
–
2.413
A2
0.381
–
–
D
12.319
–
12.573
D1
11.354
–
11.506
D2
9.906
–
10.922
E
14.859
–
15.113
E1
13.894
–
14.046
E2
12.471
–
13.487
B
0.660
–
0.813
B1
0.330
–
0.533
e
NOTE
Note 2
Note 2
1.270 TYP
10/04/01
R
2325 Orchard Parkway
San Jose, CA 95131
TITLE
32J, 32-lead, Plastic J-leaded Chip Carrier (PLCC)
DRAWING NO.
REV.
32J
B
15
0333L–FLASH–9/08
29.2
32T – TSOP Type 1
PIN 1
0º ~ 8º
c
Pin 1 Identifier
D1 D
L
b
e
L1
A2
E
A
GAGE PLANE
SEATING PLANE
COMMON DIMENSIONS
(Unit of Measure = mm)
A1
MIN
NOM
MAX
A
–
–
1.20
A1
0.05
–
0.15
A2
0.95
1.00
1.05
D
19.80
20.00
20.20
D1
18.30
18.40
18.50
Note 2
E
7.90
8.00
8.10
Note 2
L
0.50
0.60
0.70
SYMBOL
Notes:
1. This package conforms to JEDEC reference MO-142, Variation BD.
2. Dimensions D1 and E do not include mold protrusion. Allowable
protrusion on E is 0.15 mm per side and on D1 is 0.25 mm per side.
3. Lead coplanarity is 0.10 mm maximum.
L1
0.25 BASIC
b
0.17
0.22
0.27
c
0.10
–
0.21
e
NOTE
0.50 BASIC
10/18/01
R
16
2325 Orchard Parkway
San Jose, CA 95131
TITLE
32T, 32-lead (8 x 20 mm Package) Plastic Thin Small Outline
Package, Type I (TSOP)
DRAWING NO.
REV.
32T
B
AT29C040A
0333L–FLASH–9/08
Headquarters
International
Atmel Corporation
2325 Orchard Parkway
San Jose, CA 95131
USA
Tel: 1(408) 441-0311
Fax: 1(408) 487-2600
Atmel Asia
Room 1219
Chinachem Golden Plaza
77 Mody Road Tsimshatsui
East Kowloon
Hong Kong
Tel: (852) 2721-9778
Fax: (852) 2722-1369
Atmel Europe
Le Krebs
8, Rue Jean-Pierre Timbaud
BP 309
78054 Saint-Quentin-enYvelines Cedex
France
Tel: (33) 1-30-60-70-00
Fax: (33) 1-30-60-71-11
Atmel Japan
9F, Tonetsu Shinkawa Bldg.
1-24-8 Shinkawa
Chuo-ku, Tokyo 104-0033
Japan
Tel: (81) 3-3523-3551
Fax: (81) 3-3523-7581
Technical Support
[email protected]
Sales Contact
www.atmel.com/contacts
Product Contact
Web Site
www.atmel.com
Literature Requests
www.atmel.com/literature
Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise, to any
intellectual property right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL’S TERMS AND CONDITIONS OF SALE LOCATED ON ATMEL’S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTORY
WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR LOSS OF INFORMATION) ARISING OUT OF
THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF ATMEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no
representations or warranties with respect to the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications
and product descriptions at any time without notice. Atmel does not make any commitment to update the information contained herein. Unless specifically provided
otherwise, Atmel products are not suitable for, and shall not be used in, automotive applications. Atmel’s products are not intended, authorized, or warranted for use
as components in applications intended to support or sustain life.
© 2008 Atmel Corporation. All rights reserved. Atmel ®, Atmel logo and combinations thereof, and others are registered trademarks or trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be trademarks of others.
0333L–FLASH–9/08
Similar pages