Arch AKC Ac-dc power module Datasheet

VER : C_2
update : 2016.07.28
AC-DC Power Module
AKC SERIES
20
Watts
KEY FEATURES
 Switching Power Module for PCB Mountable
 Fully Encapsulated Plastic Case
 Universal Input Range 90-264VAC, 47-440 Hz
 Regulated Output
 Low Ripple and Noise
 Small Size But Higher Wattage
 CE, CB and UL Approval
 3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
( Single Output )
Max output wattage
(W)
AKC-5S
AKC-7.35S
AKC-9S
AKC-12S
AKC-15S
AKC-24S
20W
14.85W
20W
20W
20W
20W
20W
Voltage (V.DC.)
3.3V
5V
7.35V
9V
12V
15V
24V
Current (mA) max
4500
±2%
4000
±2%
2730
±2%
2230
±2%
1670
±2%
1340
±2%
840
±2%
Voltage set accuracy
Output
AKC-3.3S
Line Regulation (LL-HL) (typ.)
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
Load Regulation (0-100%) (typ.)
1%
1%
1%
1%
1%
1%
1%
Minimum load
0%
0%
0%
0%
0%
0%
0%
Efficiency (typ.)
75%
79%
82%
82%
83%
83%
84%
Capacitor Load (max.)
25000 uF
13000 uF
2200 uF
1100 uF
920 uF
820 uF
600 uF
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
( Dual Output )
Max output wattage
AKC-5D
AKC-12D
AKC-15D
20W
20W
20W
(W)
Output 1
Output 2
Output 1
Output 2
Output 1
Output 2
Voltage (V.DC.)
+5V
-5V
+12V
-12V
+15V
-15V
Current (mA) max
2000
2000
833
833
667
Voltage set accuracy
Output
667
±2%
±2%
±2%
±0.5%
±0.5%
±0.5%
Load Regulation (10-100%) (typ.)
±3%
±3%
±3%
Minimum load
0%
0%
0%
Efficiency (typ.)
79%
82%
82%
±4300 uF
±560 uF
±220 uF
Line Regulation (LL-HL) (typ.)
Capacitor Load (max.)
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
( Triple Output )
Max output wattage
Voltage (V.DC.)
Current (mA) max
AKC-5S15D
20W
20W
Output 1
Output 2
5
+12
-12
250
250
Output 1
Output 2
5
+15
-15
200
200
±2%
Line Regulation (LL-HL) (typ.)
1%
5%
1%
Load Regulation (20-100%) (typ.)
2%
5%
2%
Minimum load
Efficiency (typ.)
Capacitor Load (max.)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
2800
±2%
Output 3
2800
±2%
Voltage set accuracy
Output
AKC-5S12D
(W)
10%
Output 3
±2%
5%
5%
10%
81%
81%
3500 uF / ±220 uF
3500 uF / ±150 uF
-1-
VER : C_2
update : 2016.07.28
AC-DC Power Module
AKC SERIES
20
Watts
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input
Output
Protection
Isolation
Environment
Physical
Voltage
90-264 VAC or 100-375 VDC
Frequency (Hz)
47-440 Hz
Current (Full load)
400 mA max. (115 VAC) / 270 mA max. (230 VAC)
Inrush current (<2ms)
30 A max. (115 VAC) / 50 A max. (230 VAC)
Leakage Current
0.25 mA
External Fuse (recommend)
2 A slow blow type
Power Saving
230V < 0.5W
Ripple
<0.2% Vout +40mV max (Vp-p)
Noise
<0.5% Vout +50mV max (Vp-p)
Hold-up time (typ.)
13 ms min.
Over current protection
Above 105% rated output power
Over voltage protection
Zener diode clamp
Short circuit protection
Hiccup mode, indefinite (automatic recovery)
Input-Output (V.AC)
3000V
Input-FG (V.AC)
3000V
Output-FG (V.AC)
500V
Operating temperature
-25°C…+70°C (with derating)
Storage temperature
-40°C…+85°C
Temperature coefficient
0.02%/°C
Humidity
95% RH
MTBF
>400,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
2.73 x 1.87 x 0.85 Inches
( 69.5 x 47.5 x 21.7 mm ) Tolerance 0.5 mm
Case Material
Plastic resin (flammability to UL 94V-0)
Weight
110 g
Cooling method
Free air convection
Safety
Agency Approvals
EMI
CE, UL/cUL, CB
EMC
(Conducted & Radiated Emission)
EMS (Noise Immunity)
EN 55022 class B
EN 55024
NOTE
1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
2. The triple output required a minimum 10% loading on the output to maintain specified regulation.
Operation under no-load condition will not damage these devices; however they may not meet all listed specification.
3. Load regulation for triple output:
Main output (V1): 20% to 100% with 20% to 100% balanced on auxiliaries.
Auxiliary outputs (V2 and V3): 20% to 100% balanced on all outputs.
4. Cross regulation for dual output: asymmetrical load 25% / 100% FL
Cross regulation for triple output:
Main output 100% load, auxiliary 100%,other auxiliary25% to 100%.
Auxiliary outputs(V2 and V3):main output 100% load, auxiliary 100%,
other auxiliary 25% to 100% or main output 25%,auxiliary 25%,other auxiliary 25% to 100%.
5. It's necessary Varistor 14S471K at L / N input side in parallel.
6. Please refer to our PDF file "AC-DC Application" on our website: www.archcorp.com.tw
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : C_2
update : 2016.07.28
AC-DC Power Module
AKC SERIES
MECHANICAL DIMENSION
20
Watts
( Top View )
BLOCK DIAGRAM
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
PIN#
Single
Dual
Triple
1
FG
FG
FG
2
AC IN (N)
AC IN (N)
AC IN (N)
3
AC IN (L)
AC IN (L)
AC IN (L)
4
NO PIN
NO PIN
-DC OUT
5
-DC OUT
-DC OUT
COMMON
6
NO PIN
COMMON
+DC OUT
7
+DC OUT
+DC OUT
+5V RTN
8
NO PIN
NO PIN
+5V OUT
DERATING
-3-
VER : C_2
update : 2016.07.28
AC-DC Power Module
AKC SERIES
20
Watts
SCREW TERMINAL
AKC-A2
PIN#
Single
Dual
Triple
1
FG
FG
FG
2
AC IN (N)
AC IN (N)
AC IN (N)
3
AC IN (L)
AC IN (L)
AC IN (L)
4
NO CONNECT
NO CONNECT
-DC OUT
5
-DC OUT
-DC OUT
COMMON
6
NO CONNECT
COMMON
+DC OUT
7
+DC OUT
+DC OUT
+5V RTN
8
NO CONNECT
NO CONNECT
+5V OUT
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-4-