NSC LM1819N Air-core meter driver Datasheet

LM1819 Air-Core Meter Driver
General Description
Features
The LM1819 is a function generator/driver for air-core
(moving-magnet) meter movements. A Norton amplifier and
an NPN transistor are included on chip for signal conditioning as required. Driver outputs are self-centering and develop g 4.5V swing at 20 mA. Better than 2% linearity is guaranteed over a full 305-degree operating range.
Y
Y
Y
Y
Self-centering 20 mA outputs
12V operation
Norton amplifier
Function generator
Applications
Y
Y
Y
Air-core meter driver
Tachometers
Ruggedized instruments
Typical Application
TL/H/5263 – 1
FIGURE 1. Automotive Tachometer Application. Circuit shown operates
with 4 cylinder engine and deflects meter pointer (270§ ) at 6000 RPM.
Order Number LM1819M or LM1819N
See NS Package Number M14A or N14A
*TRW Type X463UW Polycarbonate Capacitor
**RN60D Low TC Resistor ( g 100 ppm)
² Components Required for Automotive Load Dump Protection
² ² Available from FARIA Co.
P O Box 983, Uncasville, CT 06382
Tel. 203-848-9271
C1995 National Semiconductor Corporation
TL/H/5263
RRD-B30M115/Printed in U. S. A.
LM1819 Air-Core Meter Driver
February 1995
Absolute Maximum Ratings
Operating Temperature
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales
Office/Distributors for availability and specifications.
Storage Temperature
Supply Voltage, V a (pin 13)
Power Dissipation (note 1)
BVCEO
b 40§ C to a 85§ C
b 65§ C to b 150§ C
Lead Temp. (Soldering, 10 seconds)
20V
1300 mW
260§ C
20VMIN
Electrical Characteristics VS e 13.1V TA e 25§ C unless otherwise specified
Symbol
IS
VREG
VREF
hFE
Pin(s)
Conditions
Supply Current
Parameter
13
Zero Input Frequency
(See Figure 1 )
Regulator Voltage
11
IREG e 0 mA
Regulator Output Resistance
11
IREG e 0 mA to 3 mA
Reference Voltage
4
IREF e 0 mA
Reference Output Resistance
4
IREF e 0 mA to 50 mA
Norton Amplifier Mirror Gain
5, 6
NPN Transistor DC Gain
9, 10
Function Generator Feedback
Bias Current
Drive Voltage Extremes,
Sine and Cosine
Sine Output Voltage
with Zero Input
k
1
2, 12
2
IBIAS j 20 mA
Min
8.1
Typ
8.5
Max
Units
65
mA
8.9
13.5
1.9
2.1
2.3
5.3
0.9
1.0
V
X
V
kX
1.1
125
V1 e 5.1V
ILOAD e 20 mA
V8 e VREF
Function Generator Linearity
FSD e 305§
Function Generator Gain
Meter Deflection/DV8
1.0
mA
g4
g 4.5
V
b 350
0
a 350
mV
g 1.7
%FSD
50.75
53.75
56.75
§ /V
Note 1: For operation above 25§ C, the LM1819 must be derated based upon a 125§ C maximum junction temperature and a thermal resistance of 76§ C/W which
applies for the device soldered in a printed circuit board and operating in a still-air ambient.
Application Hints
H fields (Figure 3(c)). H is proportional to the voltage applied
to a coil. Therefore, by varying both the polarity and magnitude of the coil voltages the axle assembly can be made to
rotate a full 360§ . The LM1819 is designed to drive the meter through a minimum of 305§ .
AIR-CORE METER MOVEMENTS
Air-core meters are often favored over other movements as
a result of their mechanical ruggedness and their independence of calibration with age. A simplified diagram of an aircore meter is shown in Figure 2 . There are three basic
pieces: a magnet and pointer attached to a freely rotating
axle, and two coils, each oriented at a right angle with respect to the other. The only moving part in this meter is the
axle assembly. The magnet will tend to align itself with the
vector sum of H fields of each coil, where H is the magnetic
field strength vector. If, for instance, a current passes
through the cosine coil (the reason for this nomenclature
will become apparent later) as shown in Figure 3(a) , the
magnet will align its magnetic axis with the coil’s H field.
Similarly, a current in the sine coil (Figure 3(b) ) causes the
magnet to align itself with the sine H field. If currents are
applied simultaneously to both sine and cosine coils, the
magnet will turn to the direction of the vector sum of the two
TL/H/5263 – 2
FIGURE 2. Simplified Diagram of an Air Core Meter.
2
Application Hints (Continued)
TL/H/5263 – 3
(a)
(b)
(c)
FIGURE 3. Magnet and pointer position are controlled by the H field generated by the two drive coils.
Comparing [3] to [2] we see that if HSINE varies as the sine
of i, and HCOSINE varies as the cosine of i, we will generate a net H field whose direction is the same as i. And since
the axle assembly aligns itself with the net H field, the pointer will always point in the direction of i.
In an air-core meter the axle assembly is supported by two
nylon bushings. The torque exerted on the pointer is much
greater than that found in a typical d’Arsonval movement. In
contrast to a d’Arsonval movement, where calibration is a
function of spring and magnet characteristics, air-core meter calibration is only affected by the mechanical alignment
of the drive coils. Mechanical calibration, once set at manufacture, can not change.
Making pointer position a linear function of some input is a
matter of properly ratioing the drive to each coil. The H field
contributed by each coil is a function of the applied current,
and the current is a function of the coil voltage. Our desired
result is to have i (pointer deflection, measured in degrees)
proportional to an input voltage:
[1]
i e kVIN
THE LM1819
Included in the LM1819 is a function generator whose two
outputs are designed to vary approximately as the sine and
cosine of an input. A minimum drive of g 20 mA at g 4V is
available at pins 2 (sine) and 12 (cosine). The common side
of each coil is returned to a 5.1V zener diode reference and
fed back to pin 1.
For the function generator, k j 54§ /V (in equation 1). The
input (pin 8) is internally connected to the Norton amplifier’s
output. VIN as considered in equation [1] is actually the difference of the voltages at pins 8 (Norton output/function
generator input) and 4. Typically the reference voltage at pin
4 is 2.1V. Therefore,
[4]
i e k(V8bVREF) e 54 (V8b2.1)
where k is a constant of proportionality, with units of degrees/volt. The vector sum of each coils’ H field must follow
the deflection angle i. We know that the axle assembly
always points in the direction of the vector sum of HSINE
and HCOSINE. This direction (see Figure 4 ) is found from the
formula:
[2]
(i) e arctan À l HSINE l / l HCOSINE l Ó
Recalling some basic trigonometry,
(i) e arctan(sin (i) / cos(i ))
As V8 varies from 2.1V to 7.75V, the function generator will
drive the meter through the chip’s rated 305§ range.
Air-core meters are mechanically zeroed during manufacture such that when only the cosine coil is driven, the pointer indicates zero degrees deflection. However, in some applications a slight trim or offset may be required. This is
accomplished by sourcing or sinking a DC current of a few
microamperes at pin 4.
A Norton amplifier is available for conditioning various input
signals and driving the function generator. A Norton amplifier was chosen since it makes a simple frequency to voltage
converter. While the non-inverting input (pin 6) bias is at one
diode drop above ground, the inverting input (5) is at 2.1V,
equal to the pin 4 reference. Mirror gain remains essentially
flat to IMIRROR e 5 mA. The Norton amplifier’s output (8) is
designed to source current into its load. To bypass the Norton amplifier simply ground the non-inverting input, tie the
inverting input to the reference, and drive pin 8 (Norton output/function generator input) directly.
An NPN transistor is included on chip for buffering and
squaring input signals. Its usefulness is exemplified in Figures 1 & 6 where an ignition pulse is converted to a rectangular waveform by an RC network and the transistor. The
emitter is internally connected to ground. It is important not
to allow the base to drop below b5Vdc, as damage may
occur. The 2.1V reference previously described is derived
from an 8.5V regulator at pin 11. Pin 11 is used as a stable
supply for collector loads, and currents of up to 5 mA are
easily accommodated.
[3]
TL/H/5263 – 4
FIGURE 4. The vector sum of HCOSINE and HSINE points
in a direction i measured in a clockwise direction from
HCOSINE.
3
Application Hints (Continued)
TACHOMETER APPLICATION
A measure of the operating level of any motor or engine is
the rotational velocity of its output shaft. In the case of an
automotive engine the crankshaft speed is measured using
the units ‘‘revolutions per minute’’ (RPM). It is possible to
indirectly measure the speed of the crankshaft by using the
signal present on the engine’s ignition coil. The fundamental
frequency of this signal is a function of engine speed and
the number of cylinders and is calculated (for a four-stroke
engine) from the formula:
The charge pump circuit in Figure 7 can be operated in two
modes: constant input pulse width (C1 acts as a coupling
capacitor) and constant input duty cycle (C1 acts as a differentiating capacitor). The transfer functions for these two
modes are quite diverse. However, deflection is always directly proportional to R2 and ripple is proportional to C2.
The following variables are used in the calculation of meter
deflection:
symbol description
n
number of cylinders
f e n0/120
(Hz)
(5)
where n e number of cylinders, and 0 e rotational velocity of
the crankshaft in RPM. From this formula the maximum frequency normally expected (for an 8 cylinder engine turning
4500RPM) is 300 Hz. In certain specialized ignition systems
(motorcycles and some automobiles) where the coil waveform is operated at twice this frequency ( f e 0/60). These
systems are identified by the fact that multiple coils are used
in lieu of a single coil and distributor. Also, the coils have
two outputs instead of one.
A typical automotive tachometer application is shown in Figure 1 . The coil waveform is filtered, squared and limited by
the RC network and NPN transistor. The frequency of the
pulse train at pin 9 is converted to a proportional voltage by
the Norton amplifier’s charge pump configuration. The ignition circuit shown in Figure 5 is typical of automotive systems. The switching element ‘‘S’’ is opened and closed in
synchronism with engine rotation. When ‘‘S’’ is closed, energy is stored in Lp. When opened, the current in Lp diverts
from ‘‘S’’ into C. The high voltage produced in Ls when ‘‘S’’
is opened is responsible for the arcing at the spark plug.
The coil voltage (see Figure 6 ) can be used as an input to
the LM1819 tachometer circuit. This waveform is essentially
constant duty cycle . D4 rectifies this waveform thereby preventing negative voltages from reaching the chip. C4 and
R5 form a low pass filter which attenuates the high frequency ringing, and R7 limits the input current to about 2.5mA.
R6 acts as a base bleed to shut the transistor OFF when
‘‘S’’ is closed. The collector is pulled up to the internal regulator by RREG. The output at pin 9 is a clean rectangular
pulse.
Many ignition systems use magnetic, hall effect or optical
sensors to trigger a solid state switching element at ‘‘S.’’
These systems (see the LM1815) typically generate pulses
of constant width and amplitude suitable for driving the
charge pump directly.
0, 0IDLE engine speed at redline and idle, RPM
i
pointer deflection at redline, degrees
e
charge pump input pulse width, seconds
peak to peak input voltages, volts
VIN
Di
maximum desired ripple, degrees
k
function generator gain, degrees/volt
f , f IDLE input frequency at redline and idle, Hz
Where the NPN transistor and regulator are used to create a
pulse VIN e 8.5V. Acceptable ripple ranges from 3 to 10 degrees (a typical pointer is about 3 degrees wide) depending
on meter damping and the input frequency.
The constant pulse width circuit is designed using the following equations:
VIN
k 3 mA
(1)
100 mAk
R1
10e
(2)
C1 t
R1
R1i
120R1i
e
e
(3)
R2
VINek f VINn0ek
1
1
e
(4)
C2 e
R2Di f IDLE R2Din0IDLE
The constant duty cycle equations are as follows:
RREG t 3 kX
R1 s VINx104 bRREG
C1 s e/10(RREG a R1)
RZ e i/3.54n0C1 e i/425 f C1
C2 e 425C1/Di
The values in Figure 1 were calculated with n e 4,
0 e 6000RPM, i e 270 degrees, e e 1 ms, VIN is
VREGb0.7V, and Di e 3 degrees in the constant duty cycle
mode. For distributorless ignitions these same equations will
apply if 0/60 is substituted for f .
4
TL/H/5263 – 12
Equivalent Schematic
5
Typical Applications
TL/H/5263 – 9
FIGURE 5. Typical Pulse-Squaring Circuit for
Automotive Tachometers.
TL/H/5263 – 11
TL/H/5263–10
FIGURE 6. Waveforms Encountered in Automotive
Tachometer Circuit.
FIGURE 7. Tachometer Charge Pump.
Voltage Driven Meter with Norton Amplifier Buffer
TL/H/5263 – 5
Deflection e 54 (VIN b .7)R2/R1
(degrees)
0 to 305§ deflection is obtained with .7 to 5V input.
*Full scale deflection is adjusted by trimming R2.
6
Typical Applications (Continued)
Unbuffered Voltage Driven Meter
TL/H/5263 – 6
Deflection e 54(VIN b 2.1)
(degrees)
0 to 305§ deflection is obtained for inputs of 2.1 to 7.75V.
Full scale deflection is adjusted by trimming the input voltage.
Current Driven Meter
TL/H/5263 – 7
Deflection e 54R2IIN
(degrees)
Inputs of 0 to 100 mA deflect the meter 0 to 270§ .
*Full scale deflection is adjusted by trimming R2.
7
Typical Applications (Continued)
Level Shifted Voltage Driven Meter
TL/H/5263 – 8
Deflection e 54VIN
(degrees)
Inputs of 0 to 5.65V deflect the meter through a range of 0 to 305§ .
Full scale deflection is adjusted by trimming the input voltage.
8
Physical Dimensions inches (millimeters)
14-Lead (0.150× Wide) Molded Small Outline Package, JEDEC
Order Number LM1819M
NS Package Number M14A
9
LM1819 Air-Core Meter Driver
Physical Dimensions inches (millimeters) (Continued)
Molded Dual-In-Line Package (N)
Order Number LM1819N
NS Package Number N14A
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical implant
into the body, or (b) support or sustain life, and whose
failure to perform, when properly used in accordance
with instructions for use provided in the labeling, can
be reasonably expected to result in a significant injury
to the user.
National Semiconductor
Corporation
1111 West Bardin Road
Arlington, TX 76017
Tel: 1(800) 272-9959
Fax: 1(800) 737-7018
2. A critical component is any component of a life
support device or system whose failure to perform can
be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
National Semiconductor
Europe
Fax: (a49) 0-180-530 85 86
Email: cnjwge @ tevm2.nsc.com
Deutsch Tel: (a49) 0-180-530 85 85
English Tel: (a49) 0-180-532 78 32
Fran3ais Tel: (a49) 0-180-532 93 58
Italiano Tel: (a49) 0-180-534 16 80
National Semiconductor
Hong Kong Ltd.
13th Floor, Straight Block,
Ocean Centre, 5 Canton Rd.
Tsimshatsui, Kowloon
Hong Kong
Tel: (852) 2737-1600
Fax: (852) 2736-9960
National Semiconductor
Japan Ltd.
Tel: 81-043-299-2309
Fax: 81-043-299-2408
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.
Similar pages