Mitsubishi LK1AF-9V Slim power relay with high inrush current capability Datasheet

VDE
SLIM POWER RELAY WITH
HIGH INRUSH CURRENT
CAPABILITY
24.0
.945
11.0
.433
25.0
.984
mm inch
LK-RELAYS
2. High insulation resistance between
contact and coil
1) Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
2) Surge withstand voltage between contact and coil: 10,000 V or more
3. High noise immunity realized by the
card separation structure between
contact and coil
4. Popular terminal pitch in AV equipment field
Creepage distance and clearances in compliance with IEC65
Card
Partition wall
5. Space-saving slim type
Base area: Width 11 × Length 24 mm
Width .433 × Length .945 inch
6. Conforms to the various safety standards
UL, CSA, VDE, TÜV, SEMKO, SEV, BSI
approved
mm inch
FEATURES
16.5
.650
1. High inrush current capability
1) Operating load capability:
inrush 100 A, steady 5 A
2) UL/CSA, TV-5
1
.039
COM
7.5
.295
Coil
N.O.
20
.787
1
.039
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
Nominal switching capacity
Rating
Max. switching power
(resistive
Max. switching voltage
load)
Max. switching current
Expected Mechanical (at 180 cpm)
life (min. Electrical (at 20 cpm)
ope.)
(at rated load)
Characteristics
1 Form A
Max. 100 mΩ
Silver alloy
5 A 277 V AC, 5 A 30 V DC
1,385 VA, 150 W
277 V AC, 30 V DC
5A (AC), 5 A (DC)
2 × 106
530 mW
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section.
*2 Detection current: 10mA
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time.
*5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs
*6 Half-wave pulse of sine wave: 6 ms
*7 Detection time: 10 µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
• AV equipment: TV’s, VTR’s, etc.
• OA equipment
• HA equipment
4,000 Vrms for 1 min
Min. 10,000 V
Approx. 7 ms (at 20°C 68°F)
Approx. 2 ms (at 20°C 68°F)
Temperature rise (at 70°C)
Remarks
TYPICAL APPLICATIONS
20 cpm
Min. 1,000 MΩ (at 500 V DC)
1,000 Vrms for 1 min
Max. 35°C with nominal coil voltage
at 5A contact carrying current
(resistance method)
Min. 200 m/s2
Functional*5
Shock
resistance Destructive*6
Min. 1,000 m/s2
10 to 55 Hz
Functional*7
at double amplitude of 1.5 mm
Vibration
resistance
10 to 55 Hz
Destructive
at double amplitude of 1.5 mm
Conditions for operation,
Ambient temp.
–40 to +70°C -40 to +158°F
transport and storage*8
Humidity
5 to 85%R.H.
(Not freezing and condensAir pressure
86 to 106 kPa
ing at low temperature)
105
Coil
Nominal operating power
Max. operating speed
Initial insulation resistance*1
Initial
Between open contacts
breakdown
Between contacts and coil
voltage*2
Initial surge voltage between contact and coil*3
Operate time*4 (at nominal voltage)
Release time (without diode)*4
(at nominal voltage)
Unit weight
Approx. 12 g .42 oz
ORDERING INFORMATION
Ex.
LK
1a
F
—
24V
Contact arrangement
Protective construction
Coil voltage (DC)
1a: 1 Form A
F: Flux-resistant type
5, 9, 12, 24 V
UL/CSA, TÜV, SEMKO, TV-5 approved type is standard.
(Note) Standard packing Carton: 100 pcs. Case: 500 pcs.
59
LK
TYPES AND COIL DATA (at 20°C 68°F)
Nominal
voltage,
V DC
5
9
12
24
Part No.
LK1aF-5V
LK1aF-9V
LK1aF-12V
LK1aF-24V
Pick-up voltage
V DC (max.)
(Initial)
3.5
6.3
8.4
16.8
Drop-out voltage
V DC (min.)
(Initial)
0.5
0.9
1.2
2.4
Nominal operating current, mA
(±10%)
106.4
58.8
44.2
22.1
Coil resistance,
Ω (±10%)
47
153
272
1,087
Nominal
operating power,
mW
530
530
530
530
Max. allowable
voltage,
V DC (at 20°C 68°F)
6.5
11.7
15.6
31.2
DIMENSIONS
mm inch
PC board pattern (Copper-side view)
2-0.9 dia
2-.035 dia
16.5
.650
2-1.3 dia
2-.051 dia
Max. 25
.984
7.5
.295
0.5
.020
0.5 dia. 0.3
.020 dia. .012
1.65
.065
20.0
.787
4
.157
Tolerance ±0.1 ±.004
0.4
.016
Schematic (Bottom view)
Max. 24
.945
16.5
.650
Dimension :
Max. 1mm .039 inch:
1 to 3mm .039 to .118 inch:
Min. 3mm .118 inch:
General tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
Max. 11
.433
1
.039
7.5
.295
20
.787
1
.039
REFERENCE DATA
1. Max. switching power (AC resistive load)
2. Coil temperature rise
3. Ambient temperature characteristics
Sample: LK1aF-12V, 6 pcs.
Point measured: coil inside
Contact current: 5 A
Contact current: 5 A
1
50
40
Ambient temperature
30°C
30
Ambient temperature
70°C
20
Coil applied voltage, %V
200
Temperature rise, °C
Contact current, A
10
160
140
120
100
0.1
1
10
100
Contact voltage, V
0
1000
Cold start
Pick-up voltage
10
0.1
Allowable ambient temperatures
against % coil voltages
(max. inside the coil temperature set as
115°C 239°F)
180
80
80
60
10
100 110 120
90
Coil applied voltage, %V
20
30
40
50
60
70
Ambient temperature, °C
4. Life curve
5-1. Operate & release time (without diode)
5-2. Operate & release time (with diode)
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: room temperature
Sample: LK1aF-12V, 20 pcs.
Sample: LK1aF-12V, 20 pcs.
Operate & release time, ms
250V AC resistive load
Life, ×104
15
15
10
Operate time
Release time
10
Max.
Min.
5
Operate & release time, ms
100
Operate time
Release time
10
Max.
Min.
Max.
Min.
5
Max.
Min.
1
0
1
2
3
4
Contact current, A
60
5
0
70
100
130
Coil applied voltage, %V
80
0
70
100
130
Coil applied voltage, %V
LK
Change of pick-up and drop-out voltage
AC277V
DC12V
Contact
welding
detection
and Miscontacting
detection
circuit
50
80
60
Max.
40
Pick-up voltage
Min.
Drop-out voltage
Max.
Min.
20
0
0
5
30
20
Max.
Min.
0
10
5
10
No. of operations, ×104
Change of contact resistance
50
100
80
60
Max.
Pick-up voltage
40
20
Drop-out voltage
0
0
4
Change of pick-up and drop-out voltage
Ratio against the rated voltage, % V
Tested sample: LK1aF-12V, 6 pcs.
• Overload test
Load: 7.5 A 120 V AC (60 Hz),
Inrush: 111 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 50 ope.
• Endurance test
Load: 5A 120 V AC (60 Hz),
Inrush: 78 A
Operation frequency: 10 times/min
(ON: OFF = 1 s: 5 s)
No. of operations: 25,000 ope.
40
10
No. of operations, ×10
6-2. Electrical life test
(UL lamp load test TV-5)
Contact resistance, mΩ
Circuit:
Change of contact resistance
100
0
Min.
Max.
Min.
2.5
No. of operations, ×104
Contact resistance, mΩ
Sample: LK1aF-12V, 6 pcs.
Operation frequency: 20 times/min.
(ON/OFF = 1.5s: 1.5s)
Ambient temperature: 26°C 79°F
Ratio against the rated voltage, %V
6-1. Electrical life test
(5 A 277 V AC, resistive load)
40
30
20
10
Max.
Min.
0
0
2.5
No. of operations, ×104
NOTES
1. Cleaning
This relay is not the sealed type, so it cannot be immersion cleaned. Be careful that
flux does not overflow onto the PC board
or penetrate inside the relay.
2. Soldering
We recommend the following soldering
conditions.
1) Automatic soldering
* Preheating: 100°C 212°F, within 2 mins
(PC board solder surface)
* Soldering: 260°C 500°F, within 5 s
2) Hand soldering
* Iron tip temperature: 280 to 300°C 536
to 571°F
* Soldering iron: 30 to 60W
* Soldering time: Within 3 s
For Cautions for Use, see Relay Technical Information (Page 11 to 39).