MPD A223RHI Very high isolation, 2w single & dual output dc/dc con vert er Datasheet

A200RHI Series
Very High Isolation, 2W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 2W Output Power
• 8,000 VDC Isolation
• 2 µA Leakage Current Max
• Compact DIP Case
• Single & Dual Outputs
• Meets EN55022 Class A
• 600 kH MTBF
• Industry Standard Pin-Out
RoHS Compliant
Input
Parameter
Conditions
Min.
Typ.
Max.
5 VDC Input
4.5
5.0
5.5
12 VDC Input 10.8
12.0
13.2
24 VDC Input 21.6
24.0
26.4
π (Pi) Filter (Complies with EN55022 Class A)
0.5
2,000
Input Voltage Range
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
Units
VDC
A
mW
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 10% to 100%
Typ.
±2.0
±2.0
±0.3
±0.5
30
Over Line, Load & Temp.
Max.
±4.0
±4.0
±0.5
±1.0
50
100
5
120
±0.01
50
±6.0
±0.02
Typ.
Max.
50% Load Step Change
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
µSec
%
%/ºC
Continuous
General
Parameter
Isolation Voltage, Rated
Isolation Test Voltage
Isolation Test Voltage
Leakage Current
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
Flash Tested For 1 Second
240 VAC, 60 Hz
500 VDC
100 kHz, 1V
Min.
5,600
6,000
8,000
30
80
Units
VDC
VDC
VDC
µA
GΩ
pF
kHz
Max.
+60
+90
+125
Units
ºC
ºC
ºC
95
%
2
10
20
25
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
-25
-25
-40
Free Air Convection
RH, Non-condensing
Physical
Case Size
Case Material
Weight
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.42 Oz (12g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
600
Typ.
Max.
Units
kHours
Min.
-0.7
-0.7
-0.7
Typ.
Max.
7.5
15.0
30.0
260
2,000
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
All Models
VDC
ºC
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
Voltage (VDC)
Input
Current (mA)
Nominal
Range
Full-Load
5
5
5
5
5
5
12
12
12
12
12
12
24
24
24
24
24
24
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
645
629
623
476
699
695
269
262
260
185
281
280
134
131
130
93
143
142
Output
Reflected
Efficiency
Current
Ripple Voltage Current
(%, Typ)
(VDC) (mA, Max) (mA, Min)
No-Load Current
Fuse Rating
Slow-Blow
(mA)
(mA, Typ)
A201RHI
A202RHI
A203RHI
A204RHI
A205RHI
A206RHI
A211RHI
A212RHI
A213RHI
A214RHI
A215RHI
A216RHI
A221RHI
A222RHI
A223RHI
A224RHI
A225RHI
A226RHI
100
100
100
100
100
100
50
50
50
50
50
50
30
30
30
30
30
30
15
15
15
15
15
15
8
8
8
8
8
8
3
3
3
3
3
3
5.0
12.0
15.0
±5.0
±12.0
±15.0
5.0
12.0
15.0
±5.0
±12.0
±15.0
5.0
12.0
15.0
±5.0
±12.0
±15.0
Notes:
1. When measuring output ripple, it is recommended that an external
0.33 µF ceramic capacitor be placed from the +Vout pin to the -Vout
pin for single output units and from each output to common for
dual output units. For noise sensitive applications, the use of 1.5 µF
capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a load
step change of 50% to 100%.
3. Dual output units may be connected to provide a 10 VDC, 24 VDC or
30 VDC output. To do this, connect the load across the positive (+Vout)
and negative (-Vout) outputs and float the output common.
4. The converter should be connected to a low ac-impedance source.
An input source with a highly inductive impedance may affect the
stability of the converter. In applications where the converter output
loading is high and input power is supplied over long lines, it may be
necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz)
capacitor be mounted close to the converter. For 5V input units a 4.7
µF is recommended, and for 12V & 24V units a 2.2 µF.
5. It is recommended that a fuse be used on the input of a power supply
for protection. See the table above for the correct rating.
400
165
133
±100
±83
±66
400
165
133
±100
±83
±66
400
165
133
±100
±83
±66
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
62
63
64
42
57
57
62
63
64
45
59
59
62
63
64
45
58
58
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
250
250
250
250
250
250
Derating Curve
Capacitive Load
Mechanical Dimensions
Single Output Dual Output
(µF Max)
(µF Max)
470
±220
Pin Connections
Pin
Single
Dual
1, 2
+Vin
+Vin
10, 11
No Pin
Common
12
-Vout
No Pin
13
+Vout
-Vout
15
No Pin
+Vout
23, 24
-Vin
-Vin
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]