Littelfuse CCL30-60A Cbo, cck, ccl series lift truck fuses 32-125 vdc â ¢ 1-300 a â ¢ fast acting & time delay Datasheet

POWR-GARD® Fuse Datasheet
CBO, CCK, CCL SERIES LIFT TRUCK FUSES
32-125 Vdc • 1-300 A • Fast Acting & Time Delay
Specifications
Voltage Ratings:
CBO: 32 Volts DC
CCK: 125 Volts DC (1-300A)
CCL: 125 Volts DC
Ampere Range:
1 – 300 amperes
Interrupting Rating:
10,000 A
For operating characteristics contact factory
Ordering Information
Description
AMPERE RATINGS
CBO FAST ACTING (32 Vdc)
CBO fast acting, and CCK and CCL dual-element time-delay fuses
are recommended for fork lift trucks and other similar battery
operated equipment.
Applications
1
2
10
15
Dimensions (inches)
A
A
3.070
3.740
4.460
4.720
4.710
3.07
3.49
B
2.500
3.000
3.500
3.750
3.750
2.5
2.75
25
30
35
40
20
60
70
75
80
100
125
150
—
—
—
—
AMPERE RATINGS
CCK TIME-DELAY (125 Vdc)
Lift trucks, scissor lifts, pallet movers, and other low
voltage battery operated equipment used to move
hazardous materials.
PART NO.
CCK 1-30A
CCK 35-60A
CCK 70-100A
CCK 120-200A
CCK 225-300A
CCL 30-60A
CCL 80-120A
10
12
15
20
20
25
30
35
40
50
60
70
75
80
100
120
140
150
160
175
200
225
250
300
AMPERE RATINGS
CCL TIME-DELAY (125 Vdc)
C
0.56
0.81
1.06
1.06
1.06
0.56
0.81
30
35
40
50
60
80
VOLT
DC
100
120
—
—
AMP
CATALOG
NUMBER
ORDERING
NUMBER
SERIES
TYPE
CBO
FAST ACTING
32
10
CBO010
0CBO010.V
CCK
TIME-DELAY
125
120
CCK120
0CCK120.V
CCL
TIME-DELAY
125
120
CCL120
0CCL120.V
1.625"
2.43"
B
0.812"
C
3.18"
0.343"
1.00"
CCK/CCL
littelfuse.com
CBO
1 of 1
© 2015 Littelfuse POWR-GARD® Products
Rev: 022715