R F C o m p o n e n t s July 2013 Balun Transformers Wound SMD ATB series ATB2012-50011 (2.0u1.2u1.2mm) ATB2012-75011 (2.0u1.2u1.2mm) ATB2012E-50011M (2.0u1.2u1.0mm) ATB2012E-75011M (2.0u1.2u1.0mm) (2/13) R F C o m p o n e n t s REMINDERS FOR USING THESE PRODUCTS Before using these products, be sure to request the delivery specifications. SAFETY REMINDERS Please pay sufficient attention to the warnings for safe designing when using these products. REMINDERS The storage period is less than 6 months. Be sure to follow the storage conditions (Temperature: 5 to 40°C, Humidity: 10 to 75% RH or less). If the storage period elapses, the soldering of the terminal electrodes may deteriorate. Do not use or store in locations where there are conditions such as gas corrosion (salt, acid, alkali, etc.). Before soldering, be sure to preheat components. The preheating temperature should be set so that the temperature difference between the solder temperature and chip temperature does not exceed 150°C. Soldering corrections after mounting should be within the range of the conditions determined in the specifications. If overheated, a short circuit, performance deterioration, or lifespan shortening may occur. When embedding a printed circuit board where a chip is mounted to a set, be sure that residual stress is not given to the chip due to the overall distortion of the printed circuit board and partial distortion such as at screw tightening portions. Self heating (temperature increase) occurs when the power is turned ON, so the tolerance should be sufficient for the set thermal design. Carefully lay out the coil for the circuit board design of the non-magnetic shield type. A malfunction may occur due to magnetic interference. Use a wrist band to discharge static electricity in your body through the grounding wire. Do not expose the products to magnets or magnetic fields. Do not use for a purpose outside of the contents regulated in the delivery specifications. The products listed on this catalog are intended for use in general electronic equipment (AV equipment, telecommunications equipment, home appliances, amusement equipment, computer equipment, personal equipment, office equipment, measurement equipment, industrial robots) under a normal operation and use condition. The products are not designed or warranted to meet the requirements of the applications listed below, whose performance and/or quality require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious damage to society, person or property. If you intend to use the products in the applications listed below or if you have special requirements exceeding the range or conditions set forth in the each catalog, please contact us. (1) Aerospace/Aviation equipment (2) Transportation equipment (cars, electric trains, ships, etc.) (3) Medical equipment (4) Power-generation control equipment (5) Atomic energy-related equipment (6) Seabed equipment (7) Transportation control equipment (8) Public information-processing equipment (9) Military equipment (10) Electric heating apparatus, burning equipment (11) Disaster prevention/crime prevention equipment (12) Safety equipment (13) Other applications that are not considered general-purpose applications When designing your equipment even for general-purpose applications, you are kindly requested to take into consideration securing protection circuit/device or providing backup circuits in your equipment. 001-01 / 20130723 / e751_woundbalun_atb.fm (3/13) R F C o m p o n e n t s Balun Transformers Product compatible with RoHS directive Halogen-free Compatible with lead-free solders Wound SMD Overview of the ATB Series FEATURES Chip balun transformer developed for impedance systems; ATB2012-50011 and ATB2012E-50011M are for 50: impedance and ATB2012-75011 and ATB2012E-75011M are for 75: impedance. Input impedance is 50: for ATB2012-50011 and ATB2012E-50011M, and 75: for ATB2012-75011 and ATB2012E-75011M. The impedance ratio is 1:1. The frequency band width for ATB2012-50011 is 40MHz to 860MHz (Standard IL = 1.0dB), for ATB2012E-50011M is 400MHz to 1.8GHz (Standard IL =1.0dB), for ATB2012-75011is 50MHz to 1.2GHz (Standard IL = 0.8dB), and for ATB2012E-75011M is 400MHz to 1.8GHz (Standard IL = 1.0dB). APPLICATION TV and mobile device tuners (DVB-T/H, ISDB-T, etc.) STB / tuner power divider PART NUMBER CONSTRUCTION ATB 2012 Series name - L×W×H Dimensions (mm) 2012 2.0×1.2×1.2 ATB 2012E Series name 500 Input impedance (:) 500 50 750 75 - L×W×H Dimensions (mm) 2012 2.0×1.2×1.0 11 Impedance ratio 11 500 Input impedance (:) 500 50 750 75 1:1 T TL 11 □□□ Packaging style Internal code ø180mm reel ø330mm reel M Impedance ratio 11 T 1:1 - Product internal code M T □□ Packaging style Internal code T TL ø180mm reel ø330mm reel OPERATING TEMPERATURE RANGE, PACKAGE QUANTITY, PRODUCT WEIGHT Type Temperature range Operating Storage temperature temperature (°C) (°C) ATB2012-50011 –40 to +85 –40 to +85 ATB2012-75011 –40 to +85 –40 to +85 ATB2012E-50011M –40 to +85 –40 to +85 ATB2012E-75011M –40 to +85 –40 to +85 Reel diameter ø180mm ø330mm ø180mm ø330mm ø180mm ø330mm ø180mm ø330mm Package quantity Individual weight (pieces/reel) 2,000 10,000 2,000 10,000 2,000 10,000 2,000 10,000 (mg) 10 10 10 10 Operating temperature range includes self-temperature rise. The Storage temperature range is for after the circuit board is mounted. RoHS Directive Compliant Product: See the following for more details related to RoHS Directive compliant products. http://www.tdk.co.jp/rohs/ Halogen-free: Indicates that Cl content is less than 900ppm, Br content is less than 900ppm, and that the total Cl and Br content is less than 1500ppm. • All specifications are subject to change without notice. 001-01 / 20130723 / e751_woundbalun_atb.fm (4/13) R F C o m p o n e n t s Overview of the ATB Series RECOMMENDED REFLOW PROFILE Preheating Soldering Natural cooling Peak T: Temperature T4 T3 T2 T3 t3 T1 t1 t2 t: Time Preheating Temp. T1 T2 150°C 180°C Time t1 60 to 120s Soldering Temp. Time T3 t2 230°C 10 to 30s Peak Temp. T4 245°C Time t3 5s max. • All specifications are subject to change without notice. 001-01 / 20130723 / e751_woundbalun_atb.fm (5/13) R F C o m p o n e n t s ATB series ATB2012-50011 Type SHAPE & DIMENSIONS 2.0±0.2 4 2 3 0.4 1.2±0.1 1.2±0.2 1 1.2 0.4 0.35 0.5 0.35 0.4 Dimensions in mm RECOMMENDED LAND PATTERN 2.7 CIRCUIT DIAGRAM Unbalanced Port 50Ω 1 Balanced Port 50Ω 4 0.4 1.2 3 0.8 2 Dimensions in mm • All specifications are subject to change without notice. 001-01 / 20130723 / e751_woundbalun_atb.fm (6/13) R F C o m p o n e n t s ATB series ATB2012-50011 Type ELECTRICAL CHARACTERISTICS CHARACTERISTICS SPECIFICATION TABLE Frequency range (MHz) 40 to 860 UB/B impedance (: ) 50/50 Insertion loss (dB) typ. max. 1.0 2.5 CMRR min. 20 ○ Measurement equipment Measurement item Product No. DC resistance 4338A Insulation resistance 4339A Insertion loss E5071B Return loss E5071B Amplitude imbalance E5071B Phase balance E5071B * Equivalent measurement equipment may be used. DC resistance (: )max. 1.0 Rated current (mA) 200 Rated voltage (V) 20 Insulation resistance (M: ) 10 Withstanding voltage (V) 125 Part No. ATB2012-50011-T Manufacturer Agilent Technologies Agilent Technologies Agilent Technologies Agilent Technologies Agilent Technologies Agilent Technologies FREQUENCY CHARACTERISTICS INSERTION LOSS RETURN LOSS 0 5 1.0 Return loss (dB) Insertion loss (dB) 0.0 2.0 3.0 4.0 5.0 6.0 20 25 35 5.0 4.0 3.0 2.0 1.0 0 100 200 300 400 500 600 700 800 900 1000 Frequency (MHz) 0 100 200 300 400 500 600 700 800 900 1000 Frequency (MHz) PHASE BALANCE Phase balance (deg.) Amplitude imbalance (dB) 15 30 0 100 200 300 400 500 600 700 800 900 1000 Frequency (MHz) AMPLITUDE IMBALANCE 0 10 185 184 183 182 181 180 179 178 177 176 175 0 100 200 300 400 500 600 700 800 900 1000 Frequency (MHz) • All specifications are subject to change without notice. 001-01 / 20130723 / e751_woundbalun_atb.fm (7/13) R F C o m p o n e n t s ATB series ATB2012E-50011M Type SHAPE & DIMENSIONS 2.0±0.2 4 2 3 1.0±0.1 1.2±0.2 1 1.2 0.4 0.3 0.5 0.3 0.4 Dimensions in mm RECOMMENDED LAND PATTERN 2.7 CIRCUIT DIAGRAM Unbalanced Port 50: 1 Balanced Port 50: 4 0.4 1.2 3 0.8 2 Dimensions in mm • All specifications are subject to change without notice. 001-01 / 20130723 / e751_woundbalun_atb.fm (8/13) R F C o m p o n e n t s ATB series ATB2012E-50011M Type ELECTRICAL CHARACTERISTICS CHARACTERISTICS SPECIFICATION TABLE Frequency range (MHz) 400 to 1800 UB/B impedance (: ) 50/50 Insertion loss (dB) typ. max. 1.0 2.2 CMRR min. 15 ○ Measurement equipment Measurement item Product No. DC resistance 4338A Insulation resistance 4339A Insertion loss E5071B Return loss E5071B Amplitude imbalance E5071B Phase balance E5071B * Equivalent measurement equipment may be used. DC resistance (: )max. 0.5 Rated current (mA) 150 Rated voltage (V) 20 Insulation resistance (M: ) 10 Withstanding voltage (V) 125 Part No. ATB2012E-50011M-T Manufacturer Agilent Technologies Agilent Technologies Agilent Technologies Agilent Technologies Agilent Technologies Agilent Technologies FREQUENCY CHARACTERISTICS 0 1 2 3 4 5 6 7 8 9 0 200 400 600 800 1000 1200 1400 1500 1800 Frequency (MHz) 10 9 8 7 6 5 4 3 2 1 0 0 200 400 600 800 1000 1200 1400 1500 1800 Frequency (MHz) 0 5 10 15 20 25 30 35 40 45 0 200 400 600 800 1000 1200 1400 1500 1800 Frequency (MHz) PHASE BALANCE Phase balance (deg.) AMPLITUDE IMBALANCE Amplitude imbalance (dB) RETURN LOSS Return loss (dB) Insertion loss (dB) INSERTION LOSS 200 195 190 185 180 175 170 165 160 0 200 400 600 800 1000 1200 1400 1500 1800 Frequency (MHz) • All specifications are subject to change without notice. 001-01 / 20130723 / e751_woundbalun_atb.fm (9/13) R F C o m p o n e n t s ATB series ATB2012-75011Type SHAPE & DIMENSIONS 2.0±0.2 4 2 3 0.4 1.2±0.1 1.2±0.2 1 1.2 0.4 0.35 0.5 0.35 0.4 Dimensions in mm RECOMMENDED LAND PATTERN CIRCUIT DIAGRAM Unbalanced Port 75Ω 1 2.7 Balanced Port 75Ω 4 0.4 1.2 3 0.8 2 Dimensions in mm • All specifications are subject to change without notice. 001-01 / 20130723 / e751_woundbalun_atb.fm (10/13) R F C o m p o n e n t s ATB series ATB2012-75011Type ELECTRICAL CHARACTERISTICS CHARACTERISTICS SPECIFICATION TABLE Frequency range (MHz) 50 to 1200 UB/B impedance (: ) 75/75 Insertion loss (dB) typ. max. 0.8 1.2 CMRR min. 20 ○ Measurement equipment Measurement item Product No. DC resistance 4338A Insulation resistance 4339A Insertion loss E5071B Return loss E5071B Amplitude imbalance E5071B Phase balance E5071B * Equivalent measurement equipment may be used. DC resistance (: ) 0.7 Rated current (mA) 280 Rated voltage (V) 20 Insulation resistance (M: ) 10 Withstanding voltage (V) 125 Part No. ATB2012-75011-T Manufacturer Agilent Technologies Agilent Technologies Agilent Technologies Agilent Technologies Agilent Technologies Agilent Technologies FREQUENCY CHARACTERISTICS INSERTION LOSS RETURN LOSS 1.0 Return loss (dB) Insertion loss (dB) 0.0 2.0 3.0 4.0 5.0 6.0 0 200 400 600 800 Frequency (MHz) 1000 1200 3.0 2.0 1.0 0 –1.0 –2.0 –3.0 0 200 400 600 800 Frequency (MHz) 0 200 400 600 800 Frequency (MHz) 1000 1200 1000 1200 PHASE BALANCE Phase balance (deg.) Amplitude imbalance (dB) AMPLITUDE IMBALANCE 0 –5 –10 –15 –20 –25 –30 –35 –40 1000 1200 190 188 186 184 182 180 178 176 174 172 170 0 200 400 600 800 Frequency (MHz) • All specifications are subject to change without notice. 001-01 / 20130723 / e751_woundbalun_atb.fm (11/13) R F C o m p o n e n t s ATB series ATB2012E-75011M Type SHAPE & DIMENSIONS 2.0±0.2 4 2 3 1.0±0.1 1.2±0.2 1 1.2 0.4 0.3 0.5 0.3 0.4 Dimensions in mm RECOMMENDED LAND PATTERN CIRCUIT DIAGRAM Unbalanced Port 75: 1 2.7 Balanced Port 75: 4 0.4 1.2 3 0.8 2 Dimensions in mm • All specifications are subject to change without notice. 001-01 / 20130723 / e751_woundbalun_atb.fm (12/13) R F C o m p o n e n t s ATB series ATB2012E-75011M Type ELECTRICAL CHARACTERISTICS CHARACTERISTICS SPECIFICATION TABLE Frequency range (MHz) 400 to 1800 UB/B impedance (: ) 75/75 Insertion loss (dB) typ. max. 1.0 2 DC CMRR resistance min. (: )max. 15 0.5 ○ Measurement equipment Measurement item Product No. DC resistance 4338A Insulation resistance 4339A Insertion loss E5071B Return loss E5071B Amplitude imbalance E5071B Phase balance E5071B * Equivalent measurement equipment may be used. Rated current (mA) 150 Rated voltage (V) 20 Insulation resistance (M: ) 10 Withstanding voltage (V) 125 Part No. ATB2012E-75011M-T Manufacturer Agilent Technologies Agilent Technologies Agilent Technologies Agilent Technologies Agilent Technologies Agilent Technologies FREQUENCY CHARACTERISTICS INSERTION LOSS RETURN LOSS 1 Return loss (dB) Insertion loss (dB) 0 2 3 4 5 6 0 200 400 600 800 1000 1200 1400 1500 1800 Frequency (MHz) 10 9 8 7 6 5 4 3 2 1 0 0 200 400 600 800 1000 1200 1400 1500 1800 Frequency (MHz) 0 200 400 600 800 1000 1200 1400 1500 1800 Frequency (MHz) PHASE BALANCE Phase balance (deg.) Amplitude imbalance (dB) AMPLITUDE IMBALANCE 0 5 10 15 20 25 30 35 40 200 195 190 185 180 175 170 165 160 0 200 400 600 800 1000 1200 1400 1500 1800 Frequency (MHz) • All specifications are subject to change without notice. 001-01 / 20130723 / e751_woundbalun_atb.fm (13/13) R F C o m p o n e n t s ATB series Packaging style REEL DIMENSIONS 2.0±0.5 Type ATB2012-50011 ATB2012-75011 N ATB2012E-50011M ATB2012E-75011M A ø180 ø330 ø180 ø330 ø180 ø330 ø180 ø330 W1 13 13.5 13 13.5 13 13.5 13 13.5 W2 60 100 60 100 60 100 60 100 N 9 10 9 10 9 10 9 10 P2 2.0±0.1 2.0±0.1 2.0±0.1 2.0±0.1 W 8.0±0.2 8.0±0.2 8.0±0.2 8.0±0.2 K 1.4±0.1 1.4±0.1 1.15±0.1 1.15±0.1 1.0 ø13.0±0.2 W1 ø21.0±0.8 W2 A Dimensions in mm TAPE DIMENSIONS P2 t P0 W B F E øD0 A K P1 Dimensions in mm Type ATB2012-50011 ATB2012-75011 ATB2012E-50011M ATB2012E-75011M A 1.4±0.1 1.4±0.1 1.4±0.1 1.4±0.1 B 2.25±0.1 2.25±0.1 2.25±0.1 2.25±0.1 øD0 1.5+0.1/0 1.5+0.1/0 1.5+0.1/0 1.5+0.1/0 E 1.75±0.1 1.75±0.1 1.75±0.1 1.75±0.1 F 3.5±0.1 3.5±0.1 3.5±0.1 3.5±0.1 P0 4.0±0.1 4.0±0.1 4.0±0.1 4.0±0.1 P1 4.0±0.1 4.0±0.1 4.0±0.1 4.0±0.1 t 0.25±0.05 0.25±0.05 0.2±0.05 0.2±0.05 500 to 560min. 160min. Taping 440min. Drawing direction Dimensions in mm • All specifications are subject to change without notice. 001-01 / 20130723 / e751_woundbalun_atb.fm