AIMTEC AM30K-1203SZ 30 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM30K-Z
30 Watt | DC-DC Converter
FEATURES:








Wide Input 2:1 Range
Full SMD Technology
1500 VDC Isolation
Efficiency up to 91%
Adjustable Output Voltage
Remote ON/OFF Function
Over Current, Voltage, & Temperature Protection
Soft Start
Models: Single output
Model
Input –
Voltage (V)
AM30K-1203SZ
9-18
AM30K-1205SZ
9-18
AM30K-1212SZ
9-18
AM30K-1215SZ
9-18
AM30K-2403SZ
18-36
AM30K-2405SZ
18-36
AM30K-2412SZ
18-36
AM30K-2415SZ
18-36
AM30K-4803SZ
36-75
AM30K-4805SZ
36-75
AM30K-4812SZ
36-75
AM30K-4815SZ
36-75
Add suffix “-K” for optional heat sink
Output
Voltage
(V)
Output Current
max (A)
Isolation
(VDC)
Max
Capacitive
Load (uF)
Efficiency
(%)
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
5.5
5.0
2.5
2.0
5.5
5.0
2.5
2.0
5.5
5.0
2.5
2.0
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
15000
10000
2200
1000
15000
10000
2200
1000
15000
10000
2200
1000
83
86
90
90
84
87
91
91
84
87
91
91
Output
Voltage
(V)
Output Current
max (A)
Isolation
(VDC)
Max
Capacitive
Load (uF)
Efficiency
(%)
±12
±15
±12
±15
±12
±15
±1.25
±1.0
±1.25
±1.0
±1.25
±1.0
1500
1500
1500
1500
1500
1500
±1000
±680
±1000
±680
±1000
±680
90
90
91
91
90
90
Models: Dual output
Model
Input –
Voltage (V)
AM30K-1212DZ
9-18
AM30K-1215DZ
9-18
AM30K-2412DZ
18-36
AM30K-2415DZ
18-36
AM30K-4812DZ
36-75
AM30K-4815DZ
36-75
Add suffix “-K” for optional heat sink
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Input Specifications
Nominal
Typical
12
24
48
9-18
18-36
36-75
Voltage range
Filter
Start up time
Absolute Maximum Rated Input
Voltage
Peak Input Voltage time
On/Off Control
Maximum
Units
VDC
π(Pi) Network
20
ms
25
VDC
50
100
100
ms
ON – high or open (2.5V TO 5.5V); OFF – low (-0.7V to 0.8V or short circuit between pin 2 & 3)
12
24
48
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
www.aimtec.com
F 051e R8.G
Conditions
Typical
3 sec
1000
1200
Tel: +1 514 620 2722
1 of 4
Rated
Units
1500
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30K-Z
30 Watt | DC-DC Converter
Output Specifications
Output Specifications
Voltage accuracy
Voltage balance (Dual Output model)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation (Single)
Line voltage regulation (Dual)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
Voltage adjustment range
Conditions
Typical
Maximum
±5
±5
125
120
Balanced Load
HL-LL
HL-LL
10% to 100% Load
10% to 100% Load
At 20MHz Bandwidth
Units
%
%
%
%
Continuous
Auto Recovery
±5
±5
±0.5
±0.5
±0.02
75
±10
%
%
%
%
%/oC
m Vp-p
%
General Specifications
Input Specifications
Conditions
Typical
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Over Temperature Protection
Case material
Weight
Dimensions (L X W X H)
MTBF
100% load
With derating above 60 oC (see graph below)
270
Maximum
Units
-40 to +85
-40 to +125
100
Free air convection
95
110
Nickel-coated Copper and Epoxy (UL94V-0 rated)
48
2.00 x1.60 x0.40 inches
50.80 x 40.60 x 10.20 mm
>1000000 hrs Calculated using MIL-HDBK-217 F at +25 oC
KHz
o
C
o
C
%
g
Safety Specifications
Standards
Agency approvals
CE
IEC/EN 60950-1
EN55022 Class A
EN55022 Class A
EN61000-4-2 Perf. Criteria B
EN61000-4-3 Perf. Criteria A
EN61000-4-4 Perf. Criteria B
EN61000-4-5 Perf. Criteria B
EN61000-4-6 Perf. Criteria A
EN61000-4-8 Perf. Criteria A
Safety
Pin Out Specifications
Pin
Single
Dual
1
2
3
4
5
6
7
+Vin
-Vin
On/Off Control
No Pin
+Vout
-Vout
Trim
+Vin
-Vin
On/Off Control
+Vout
Com
-Vout
Trim
www.aimtec.com
F 051e R8.G
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30K-Z
30 Watt | DC-DC Converter
Dimensions
50.80
(2.00)
4
1
2
5
Bottom View
6
3
Printed
Face
7
45.72
(1.80)
Built-in Stand-offs to
ease PCB Cleaning
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Pitch Tolerance ±0.35 (±0.014)
2.54
(0.10)
Ø 1.00
(0.04)
Dimensions with Optional Heat Sink
Notes: Add “-K” suffix for ordering, heat sink is affixed with thermally dissipative adhesive tape.
See derating graph for temperature performance. Heat sink material is anodized (black) aluminum, adds weight 17g to total
mass (65g). Thermal impedance of converter is: with heatsink 8.7 Ԩ/W and 10Ԩ/W without heat sink.
Trimming
www.aimtec.com
F 051e R8.G
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30K-Z
30 Watt | DC-DC Converter
Derating
Extended temperature performance can be achieved with optional heat sink. (add suffix “–K” to part number)
Control ON/OFF pin connection example:
Note A: An external filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5.
The filter capacitor Aimtec suggests: 1000uF, 100V.
Models
AM30K-12XXXZ
AM30K-24XXXZ
AM30K-48XXXZ
C1
330 μf, 100V
330 μf, 100V
330 μf, 100V
L
12μH
12μH
12μH
C2
100μ, 100V
100μ, 100V
100μ, 100V
C3
N/A
N/A
1000Pf, 2000V
Note B: Input filter components (C1, C2, L) are used to help meet conducted emissions requirement for the module. These components should be
mounted as close as possible to the module; and all leads should be minimized to decrease radiated noise.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R8.G
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only