Embedded Power for Business-Critical Continuity Rev. 11.3.09_85 ADN-C Series 1 of 3 ADN-C Series 120 - 480 Watts Total Power: Input Voltage: # of Outputs: Slim r w e N acto F m For 120-480 Watts 85-264 Vac, 90-375 Vdc Single Electrical Specifications Special Features • Slim form factor • Five year warranty • High Efficiency > 90% Typ. • Full Power at 60 °C • Power Boost ™ • Industrial Grade Design • Patented metal mounting clip • Metal case • MTBF > 450,000h demonstrated at 40 °C • Active PFC > 0.92 • Adjustable output • Overvoltage protection with autorecovery • Continuous short circuit and overload protection • SEMI F47 Sag Immunity • New visual diagnostic LED • 3 Status LEDs Input DC Input range: Nominal: 115 - 230 Vac 85 - 264 Vac 90-375 Vdc Frequency: 47-67 Hz, 400 Hz Efficiency: > 90% ADN5-24-1PM-C: ADN10-24-1PM-C: ADN20-24-1PM-C: Active, better than 0.92 AC Input range: Inrush current: PFC: < 15 A < 30 A < 40 A Output Nominal voltage: Initial Voltage Setting: Hold-up time: Voltage regulation: ADN5-24-1PM-C & ADN10-24-1PM-C: 24 Vdc (22.5 - 28.5 Vdc Adj) ADN20-24-1PM-C: 24 Vdc (24-28 Vdc Adj) 24.5 V ± 1% > 20 ms at full load (100 Vac Input @ Tamb = +25 °C) Back EMF immunity: < ± 2% (combination line, load, time and temperature related changes) ADN5-24-1PM-C & ADN10-24-1PM-C: < 50 mVpp ADN20-24-1PM-C: < 100 mVpp < 35 Vdc • DC OK Relay • Parallel Operation Capability • Screw terminal connections • RoHS Compliant • No tools required for mounting Power Boost™: 1.5 x Nominal current for 4 seconds. Short circuit current: Safety Ouput Noise suppression: 1.5 x Nominal current at near zero volts at short circuit condition Switch selectable single unit or parallel unit operation. Units will not be damaged by parallel operation (regardless of switch position setting) Radiated EMI values below EN61000-6-2 • Input • Output • Alarm • UL508, cULus Listed • UL 60950-1, cURus • IEC60950-1 • Class I, Div 2 Hazardous Locations • IP20 • CE Ripple: Parallel operation: Overvoltage protection: > 30.5 Vdc but < 33 Vdc, auto recovery Line and Load regulation: < 0.5% Time and Temperature Drift: < 1% Embedded Power for Business-Critical Continuity Rev. 11.3.09_85 ADN-C Series 2 of 3 General Specifications EMC Emissions: EMC Immunity: Warranty: EN61000-6-2:2001, EN61000-6-3:2001, Class B EN55011, EN55022 Radiated and Conducted including Annex. A, EN61000-3-2 EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and level 3 output. EN61000-4-5 Isolation class 4, EN61000-4-11, IEC 61000-4-34 voltage dip immunity standard 5 Years General protection safety: Status Indicators: Protected against continuous short-circuit, continuous overload, continous open circuit. Protection Class 1 (IEC536), degree of protection IP20 (IEC60529) Safe low voltage: SELV (acc. IEC60950-1) Visual: 3 status LEDs (Input, Output, Alarm) Relay: N.O. contact rated 200 mA/50 Vdc LED Diagnostics LED OK Loss of Ac Low Ac No Dc High Load Overload Hot Too Hot • Input Green --- Yellow Green Green Green Green Green • Output Green --- Green --- Yellow Yellow Green --- • Alarm --- --- --- Red Yellow Red Yellow Yellow Environmental Specifications Storage/shipment: Operation (convection): -25 °C to + 85 °C ADN5-24-1PM-C & ADN10-24-1PM-C: ADN20-24-1PM-C: Full Load -10 °C to + 60 °C derate to 50% load at +70 °C Full Load -25 °C to + 60 °C derate to 50% load at +70 °C Up to 50% load permissable with horizontal or on top mounting orientation Other Features External fusing: Not required. Unit provides internal fuse (not accessible) Mounting orientation: Standard: Vertical, Optional: Horizontal or on Top Simple snap-on to DIN TS35/7.5 or TS35/15 rail system Ventilation: Normal convection, No fan required Cooling Spacing ADN5-24-1PM-C & ADN10-24-1PMC: ADN20-24-1PMC: Connections: 15 mm in front, 25 mm above and below, 10 mm left and right 15 mm in front, 40 mm above and below, 10 mm left and right Input: Screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors Output: Two terminals per output, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors Embedded Power for Business-Critical Continuity Americas Ordering Information Model Number Power Input Voltage ADN5-24-1PM-C 120 W ADN10-24-1PM-C 240 W ADN20-24-1PM-C 480 W 85-264 Vac 90-375 Vdc* Weight Current Case Type 1.65 lbs (750 g) 5A @ 24 Vdc Metal with patented 1.98 lbs (900 g) 10 A @ 24 Vdc mounting 2.6 lbs (1200 g) 20 A @ 24 Vdc clip MTBF Demonstrated at 40 °C 550,000 hours Europe (UK) Dimensions ADN5-24-1PM-C ADN10-24-1PM-C ADN20-24-1PM-C Width 4.85 in (123 mm) 1.97 in (50 mm) 2.36 in (60 mm) 3.42 in (87 mm) 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 450,000 hours *No UL listed for DC input Height Rev. 11.3.09_85 ADN-C Series 3 of 3 Depth 4.37 (111 mm) 4.96 in (126 mm) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) Mechanical Drawing D W 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.PowerConversion.com + - + techsupport.embeddedpower @emerson.com OK 24 VDC / 5 A Input Output Alarm 22.5 - 28/5 Vdc While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Single Parallel H Emerson Network Power. The global leader in enabling business-critical continuity. ADN5-24-1PM-C AC Power Connectivity C U L DC Power US LISTED 115/230 V ~ 2.2/1.0 A 50/60 HZ N L Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co.