AD AD5174BRMZ-10-RL7 Single-channel, 1024-position, digital rheostat with spi interface and 50-tp memory Datasheet

Single-Channel, 1024-Position, Digital Rheostat
with SPI Interface and 50-TP Memory
AD5174
FEATURES
APPLICATIONS
Mechanical rheostat replacements
Op-amp: variable gain control
Instrumentation: gain, offset adjustment
Programmable voltage-to-current conversions
Programmable filters, delays, time constants
Programmable power supply
Sensor calibration
FUNCTIONAL BLOCK DIAGRAM
VDD
POWER-ON
RESET
AD5174
RDAC
REGISTER
SCLK
SYNC
SPI
SERIAL
INTERFACE
A
10
W
50-TP
MEMORY
BLOCK
DIN
SDO
VSS
EXT_CAP
GND
08718-001
Single-channel, 1024-position resolution
10 kΩ nominal resistance
50-times programmable (50-TP) wiper memory
Rheostat mode temperature coefficient: 35 ppm/°C
2.7 V to 5.5 V single-supply operation
±2.5 V to ±2.75 V dual-supply operation for ac or bipolar
operations
SPI-compatible interface
Wiper setting and memory readback
Power on refreshed from memory
Resistor tolerance stored in memory
Thin LFCSP 10-lead, 3 mm × 3 mm× 0.8 mm package
Compact MSOP, 10-lead, 3 mm × 4.9 mm × 1.1 mm package
Figure 1.
GENERAL DESCRIPTION
The AD5174 is a single-channel, 1024-position digital rheostat
that combines industry leading variable resistor performance
with nonvolatile memory (NVM) in a compact package.
This device supports both dual-supply operation at ±2.5 V to
±2.75 V and single-supply operation at 2.7 V to 5.5 V and offers
50-times programmable (50-TP) memory.
The AD5174 device wiper settings are controllable through the
SPI digital interface. Unlimited adjustments are allowed before
programming the resistance value into the 50-TP memory. The
AD5174 does not require any external voltage supply to facilitate fuse blow and there are 50 opportunities for permanent
programming. During 50-TP activation, a permanent blow fuse
command freezes the resistance position (analogous to placing
epoxy on a mechanical rheostat).
The AD5174 is available in a 3 mm × 3mm 10-lead LFCSP
package and in a 10-lead MSOP package. The part is guaranteed
to operate over the extended industrial temperature range of
−40°C to +125°C.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2010 Analog Devices, Inc. All rights reserved.
AD5174
TABLE OF CONTENTS
Features .............................................................................................. 1
Shift Register ............................................................................... 12
Applications ....................................................................................... 1
RDAC Register............................................................................ 12
Functional Block Diagram .............................................................. 1
50-TP Memory Block ................................................................ 12
General Description ......................................................................... 1
Write Protection ......................................................................... 12
Revision History ............................................................................... 2
RDAC and 50-TP Read Operation .......................................... 13
Specifications..................................................................................... 3
Shutdown Mode ......................................................................... 14
Electrical Characteristics ............................................................. 3
Reset ............................................................................................. 14
Interface Timing Specifications .................................................. 4
Daisy-Chain Operation ............................................................. 15
Absolute Maximum Ratings............................................................ 6
RDAC Architecture .................................................................... 15
Thermal Resistance ...................................................................... 6
Programming the Variable Resistor ......................................... 16
ESD Caution .................................................................................. 6
EXT_CAP Capacitor.................................................................. 17
Pin Configuration and Function Descriptions ............................. 7
Terminal Voltage Operating Range ......................................... 17
Typical Performance Characteristics ............................................. 8
Power-Up Sequence ................................................................... 17
Test Circuits ..................................................................................... 11
Outline Dimensions ....................................................................... 18
Theory of Operation ...................................................................... 12
Ordering Guide .......................................................................... 18
Serial Data Interface ................................................................... 12
REVISION HISTORY
3/10—Revision 0: Initial Version
Rev. 0 | Page 2 of 20
AD5174
SPECIFICATIONS
ELECTRICAL CHARACTERISTICS
VDD = 2.7 V to 5.5 V, VSS = 0 V; VDD = 2.5 V to 2.75 V, VSS = −2.5 V to −2.75 V; −40°C < TA < 125°C, unless otherwise noted.
Table 1.
Parameter
DC CHARACTERISTICS—RHEOSTAT MODE
Resolution
Resistor Integral Nonlinearity 2, 3
Symbol
Test Conditions/Comments
Min
R-INL
|VDD − VSS| = 3.6 V to 5.5 V
|VDD − VSS| = 3.3 V to 3.6 V
|VDD − VSS| = 2.7 V to 3.3 V
Resistor Differential Nonlinearity2
Nominal Resistor Tolerance
Resistance Temperature Coefficient 4, 5
Wiper Resistance
RESISTOR TERMINALS
Terminal Voltage Range4, 6
Capacitance A4
Capacitance W4
Common-Mode Leakage Current4
DIGITAL INPUTS
Input Logic4
High
Low
Input Current
Input Capacitance4
DIGITAL OUTPUT
Output Voltage4
High
Low
R-DNL
10
−1
−1
−2.5
−1
Tristate Leakage Current
Output Capacitance4
POWER SUPPLIES
Single-Supply Power Range
Dual-Supply Power Range
Supply Current
Positive
Negative
50-TP Store Current4, 7
Positive
Negative
50-TP Read Current4, 8
Positive
Negative
Power Dissipation 9
Power Supply Rejection Ratio4
VSS
f = 1 MHz, measured to GND, code = half scale
f = 1 MHz, measured to GND, code = half scale
V A = VW
VINH
VINL
IIN
CIN
VOH
VOL
Max
+1
+1.5
+2.5
+1
±15
35
35
Code = full scale
Code = zero scale
VTERM
Typ 1
70
VDD
90
40
50
2.0
0.8
±1
5
RPULL_UP = 2.2 kΩ to VDD
RPULL_UP = 2.2 kΩ to VDD
VDD = 2.7 V to 5.5 V, VSS = 0 V
VDD = 2.5 V to 2.75 V, VSS = −2.5 V to −2.75 V
VDD − 0.1
2.7
±2.5
IDD_OTP_READ
ISS_OTP_READ
PDISS
PSRR
5.5
±2.75
V
V
1
μA
μA
4
−4
mA
mA
500
−500
VIH = VDD or VIL = GND
ΔVDD/ΔVSS = ±5 V ± 10%
Rev. 0 | Page 3 of 20
5.5
−50
V
V
μA
pF
V
V
μA
pF
−1
IDD_OTP_STORE
ISS_OTP_STORE
V
pF
pF
nA
0.4
0.6
+1
5
IDD
ISS
Bits
LSB
LSB
LSB
LSB
%
ppm/°C
Ω
V
−1
VSS = 0 V
Unit
−55
μA
μA
μW
dB
AD5174
Parameter
DYNAMIC CHARACTERISTICS4, 10
Bandwidth
Total Harmonic Distortion
Resistor Noise Density
Symbol
Test Conditions/Comments
Min
−3 dB, RAW = 5 kΩ, Terminal W, see Figure 24
VA = 1 V rms, f = 1 kHz, RAW = 5 kΩ
RWB = 5 kΩ, TA = 25°C, f = 10 kHz
1
Typ 1
700
−90
13
Max
Unit
kHz
dB
nV/√Hz
Typical specifications represent average readings at 25°C, VDD = 5 V, and VSS = 0 V.
Resistor position nonlinearity error (R-INL) is the deviation from an ideal value measured between the maximum resistance and the minimum resistance wiper
positions. R-DNL measures the relative step change from the ideal between successive tap positions.
3
The maximum current in each code is defined by IAW = (VDD − 1)/RAW.
4
Guaranteed by design and not subject to production test.
5
See Figure 9 for more details.
6
Resistor Terminal A and Resistor Terminal W have no limitations on polarity with respect to each other. Dual-supply operation enables ground referenced bipolar
signal adjustment.
7
Different from operating current; the supply current for the fuse program lasts approximately 55 ms.
8
Different from operating current; the supply current for the fuse read lasts approximately 500 ns.
9
PDISS is calculated from (IDD × VDD) + (ISS × VSS).
10
All dynamic characteristics use VDD = +2.5 V, VSS = −2.5 V.
2
INTERFACE TIMING SPECIFICATIONS
VDD = 2.7 V to 5.5 V, VSS = 0 V; VDD = 2.5 V, VSS = −2.5 V; all specifications TMIN to TMAX, unless otherwise noted.
Table 2.
Parameter
t1 2
t2
t3
t4
t5
t6
t7
t8 3
t9
t10 4
tMEMORY_READ
tMEMORY_PROGRAM
tRESET
tPOWER-UP 5
Limit 1
20
10
10
15
5
5
1
400
15
450
6
350
600
2
Unit
ns min
ns min
ns min
ns min
ns min
ns min
ns min
ns min
ns min
ns max
μs max
ms max
μs max
ms max
Test Conditions/Comments
SCLK cycle time
SCLK high time
SCLK low time
SYNC to SCLK falling edge setup time
Data setup time
Data hold time
SCLK falling edge to SYNC rising edge
Minimum SYNC high time
SYNC rising edge to next SCLK fall ignored
SCLK rising edge to SDO valid
Memory readback execute time
Memory program time
Reset OTP restore time
Power-on 50-TP restore time
1
All input signals are specified with tr = tf = 1 ns/V (10% to 90% of VDD) and timed from a voltage level of (VIL + VIH)/2.
Maximum SCLK frequency is 50 MHz.
Refer to tMEMORY_READ and tMEMORY_PROGRAM for memory commands operations.
4
RPULL_UP = 2.2 kΩ to VDD with a capacitance load of 168 pF.
5
Maximum time after VDD − VSS is equal to 2.5 V.
2
3
Rev. 0 | Page 4 of 20
AD5174
Shift Register and Timing Diagrams
DB9 (MSB)
C3
0
C2
C1
C0
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
08718-002
0
DB0 (LSB)
DATA BITS
CONTROL BITS
Figure 2. Shift Register Content
t4
t2
t7
t1
SCLK
t8
t9
t3
SYNC
t5
0
0
C3
C2
D7
D6
D5
D2
D1
t6
D0
08718-003
DIN
SDO
Figure 3. Write Timing Diagram, CPOL=0, CPHA = 1
SCLK
t9
SYNC
DIN
0
0
C3
D0
D0
0
0
C3
D1
D0
D1
D0
SDO
X
X
C3
Figure 4. Read Timing Diagram, CPOL=0, CPHA = 1
Rev. 0 | Page 5 of 20
08718-004
t10
AD5174
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 3.
Parameter
VDD to GND
VSS to GND
VDD to VSS
VA, VW to GND
Digital Input and Output Voltage to GND
EXT_CAP to VSS
IA, IW
Pulsed 1
Frequency > 10 kHz
Frequency ≤ 10 kHz
Continuous
Operating Temperature Range 3
Maximum Junction Temperature
(TJ Maximum)
Storage Temperature Range
Reflow Soldering
Peak Temperature
Time at Peak Temperature
Package Power Dissipation
Rating
–0.3 V to +7.0 V
+0.3 V to −7.0 V
7V
VSS − 0.3 V, VDD + 0.3 V
−0.3 V to VDD + 0.3 V
7V
±6 mA/d 2
±6 mA/√d2
±6 mA
−40°C to +125°C
150°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only and functional operation of the device at these or
any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
THERMAL RESISTANCE
θJA is defined by JEDEC specification JESD-51 and the value is
dependent on the test board and test environment.
Table 4. Thermal Resistance.
Package Type
10-Lead LFCSP
10-Lead MSOP
1
JEDEC 2S2P test board, still air (0 m/sec airflow).
−65°C to +150°C
ESD CAUTION
260°C
20 sec to 40 sec
(TJ max − TA)/θJA
θJA1
50
135
1
Maximum terminal current is bounded by the maximum current handling of
the switches, maximum power dissipation of the package, and maximum
applied voltage across any two of the A and W terminals at a given
resistance.
2
Pulse duty factor.
3
Includes programming of 50-TP memory.
Rev. 0 | Page 6 of 20
θJC
3
N/A
Unit
°C/W
°C/W
AD5174
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
10 SYNC
VDD 1
A
W 3
2
VSS 4
10
SYNC
9
SCLK
8
DIN
7
SDO
6
GND
AD5174
TOP VIEW
(Not to Scale)
EXT_CAP 5
VSS 4
EXT_CAP 5
08718-005
VDD 1
AD5174
9 SCLK
8 DIN
W 3
(EXPOSED
PAD)*
7 SDO
6 GND
*LEAVE FLOATING OR CONNECTED TO VSS.
Figure 5. MSOP Pin Configuration
08718-103
A 2
Figure 6. LFCSP Pin Configuration
Table 5. Pin Function Descriptions
Pin No.
1
2
3
4
Mnemonic
VDD
A
W
VSS
5
EXT_CAP
6
7
GND
SDO
8
DIN
9
SCLK
10
SYNC
EPAD
Exposed Pad
Description
Positive Power Supply. Decouple this pin with 0.1 μF ceramic capacitors and 10 μF capacitors.
Terminal A of RDAC. VSS ≤ VA ≤ VDD.
Wiper Terminal of RDAC. VSS ≤ VW ≤ VDD.
Negative Supply. Connect to 0 V for single-supply applications. Decouple this pin with 0.1 μF ceramic capacitors
and 10 μF capacitors.
External Capacitor. Connect a 1 μF capacitor between EXT_CAP and VSS. This capacitor must have a voltage
rating of ≥7 V.
Ground Pin, Logic Ground Reference.
Serial Data Output. This open-drain output requires an external pull-up resistor. SDO can be used to clock data
from the shift register in daisy-chain mode or in readback mode.
Serial Data Line. This pin is used in conjunction with the SCLK line to clock data into or out of the 16-bit
input register.
Serial Clock Input. Data is clocked into the shift register on the falling edge of the serial clock input. Data can be
transferred at rates of up to 50 MHz.
Falling Edge Synchronization Signal. This is the frame synchronization signal for the input data. When SYNC
goes low, it enables the shift register and data is transferred in on the falling edges of the subsequent clocks.
The selected register is updated on the rising edge of SYNC following the 16th clock cycle. If SYNC is taken
high before the 16th clock cycle, the rising edge of SYNC acts as an interrupt, and the write sequence is ignored
by the RDAC.
Leave floating or connected to VSS
Rev. 0 | Page 7 of 20
AD5174
TYPICAL PERFORMANCE CHARACTERISTICS
0.8
1.0
+25°C
–40°C
+125°C
0.6
VDD/VSS = 5V/0V
0.8
CURRENT (mA)
INL (LSB)
0.4
0.2
0
0.6
0.4
–0.2
0.2
–0.4
128
256
384
512
640
768
896
1023
CODE (Decimal)
0
0
0.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
Figure 10. Supply Current (IDD) vs. Digital Input Voltage
+25°C
–40°C
+125°C
0.3
1.5
VOLTAGE (V)
Figure 7. R-INL vs. Code vs. Temperature
0.4
1.0
08718-023
0
08718-014
–0.6
500
400
IDD = 5V
300
0.2
CURRENT (nA)
DNL (LSB)
200
0.1
0
–0.1
IDD = 3V
100
ISS = 3V
0
–100
–200
ISS = 5V
–300
–0.2
128
256
384
512
640
768
896
1023
CODE (Decimal)
–500
–40 –30 –20 –10 0
08718-015
0
10 20 30 40 50 60 70 80 90 100 110
TEMPERATURE (°C)
Figure 8. R-DNL vs. Code vs. Temperature
08718-018
–400
–0.3
Figure 11. Supply Current (IDD, ISS) vs. Temperature
7
VDD/VSS = 5V/0V
600
VDD/VSS = 5V/0V
6
THEORETICAL lWA_MAX (mA)
500
400
300
200
100
4
3
2
0
128
256
384
512
640
768
CODE (Decimal)
896
1023
Figure 9. Tempco ΔRWA/ΔT vs. Code
0
0
85
170 255 340 425 510 595 680 765 850 935 1023
CODE (Decimal)
Figure 12. Theoretical Maximum Current vs. Code
Rev. 0 | Page 8 of 20
08718-028
0
5
1
08718-019
RHEOSTAT MODE TEMPCO (ppm/°C)
700
AD5174
–20
0
–5
0x200
–10
0x100
–30
–35
0x080
–20
PSRR (dB)
GAIN (dB)
–15
VDD/VSS = 5V/0V
CODE = HALF SCALE
–25
0x040
–25
0x020
–40
–45
–30
0x010
0x004
0x002
–55
0x001
1
VDD/VSS = 5V/0V
10
100
1k
10k
100k
1M
–60
10
08718-031
–45
–50
–50
0x008
–40
10M
FREQUENCY (Hz)
100
1k
10k
100k
08718-024
–35
1M
FREQUENCY (Hz)
Figure 13. Bandwidth vs. Frequency vs. Code
Figure 16. PSRR vs. Frequency
8
0
VDD/VSS = ±2.5V
CODE = HALF SCALE
fIN = 1V rms
–20 NOISE BW = 22kHz
7
VOLTAGE (V)
THD + N (dB)
–40
–60
6
–80
5
–100
1k
10k
1M
100k
4
FREQUENCY (Hz)
0.07
0.11
0.13
20
VDD/VSS = ±2.5V
IAW = 200µA
10
GLITCH AMPLITUDE (mV)
–20
–40
–60
0
–10
–20
–30
–40
–50
–60
0.1
AMPLITUDE (V rms)
1
–70
–2
08718-026
THD + N (dB)
0.17
Figure 17. VEXT_CAP Waveform While Writing Fuse
10kΩ
–80 V /V = ±2.5V
DD SS
CODE = HALF SCALE
fIN = 1kHz
NOISE BW = 22kHz
–100
0.001
0.01
0.15
TIME (Seconds)
Figure 14. THD + N vs. Frequency
0
0.09
08718-029
100
0
2
TIME (µs)
Figure 15. THD + N vs. Amplitude
Figure 18. Maximum Glitch Energy
Rev. 0 | Page 9 of 20
4
08718-102
10
08718-039
–120
AD5174
1.0
0.006
VDD/VSS = 5V/0V
IAW = 10µA
CODE = HALF SCALE
0.005
ΔRAW RESISTANCE (%)
0
–0.5
0.004
0.003
0.002
0.001
0
–1.0
0
10
20
30
40
TIME (µs)
50
60
Figure 19. Digital Feedthrough
–0.002
0
100
200
300
400
500
600
700
800
900
1000
OPERATION AT 150°C (Hours)
Figure 20. Long-Term Drift Accelerated Average by Burn-In
Rev. 0 | Page 10 of 20
08718-101
–1.5
–10
–0.001
VDD/VSS = ±2.5V
IAW = 200µA
08718-100
VOLTAGE (mV)
0.5
AD5174
TEST CIRCUITS
Figure 21 to Figure 25 define the test conditions used in the Specifications section.
DUT
IW
A
A
VMS
08718-033
VMS
DUT
VMS
RWA = IW
CODE = 0x00
W
IW
RW =
V
Figure 24. Gain vs. Frequency
Figure 21. Resistor Position Nonlinearity Error
(Rheostat Operation; R-INL, R-DNL)
DUT
1GΩ
W
W
08718-036
DUT
GND
ICM
W
+2.75V
–2.75V
RWA
A
2
GND
+2.75V
V+ = VDD ±10%
PSRR (dB) = 20 log
IW
W
V+
PSS (%/%) =
NC = NO CONNECT
–2.75V
Figure 25. Common Leakage Current
Figure 22. Wiper Resistance
VDD
GND
NC
08718-034
VMS
VMS
VDD
ΔVMS%
ΔVDD%
VMS
08718-035
A
Figure 23. Power Supply Sensitivity (PSS, PSRR)
Rev. 0 | Page 11 of 20
08718-037
A
AD5174
THEORY OF OPERATION
The AD5174 is designed to operate as a true variable resistor for
analog signals within the terminal voltage range of VSS < VTERM
< VDD. The RDAC register contents determine the resistor wiper
position. The RDAC register acts as a scratchpad register, which
allows unlimited changes of resistance settings. The RDAC register
can be programmed with any position setting by using the SPI
interface. When a desirable wiper position is found, this value
can be stored in a 50-TP memory register. Thereafter, the wiper
position is always restored to that position for subsequent
power-ups. The storing of 50-TP data takes approximately 350 ms;
during this time, the AD5174 locks to prevent any changes from
taking place.
The AD5174 also feature a patented 1% end-to-end resistor
tolerance. This simplifies precision, rheostat mode, and openloop applications where knowledge of absolute resistance is
critical.
SERIAL DATA INTERFACE
The AD5174 contains a serial interface (SYNC, SCLK, DIN,
and SDO) that is compatible with SPI interface standards, as well
as most DSPs. This device allows writing of data via the serial
interface to every register.
SHIFT REGISTER
The shift register is 16 bits wide, as shown in Figure 2. The
16-bit word consists of two unused bits, which should be set to
0, followed by four control bits and 10 RDAC data bits. Data is
loaded MSB first (Bit D9). The four control bits determine the
function of the software command as listed in Table 6. Figure 3
shows a timing diagram of a typical AD5174 write sequence.
The write sequence begins by bringing the SYNC line low. The
SYNC pin must be held low until the complete data-word is
loaded from the DIN pin. When SYNC returns high, the serial
data-word is decoded according to the instructions in Table 6.
The command bits (Cx) control the operation of the digital
potentiometer. The data bits (Dx) are the values that are loaded
into the decoded register. The AD5174 has an internal counter
that counts a multiple of 16 bits (a frame) for proper operation.
For example, AD5174 works with a 32-bit word but does not
work properly with a 31-bit or 33-bit word. The AD5174
does not require a continuous SCLK when SYNC is high.
To minimize power consumption in the digital input buffers,
operate all serial interface pins close to the VDD supply rails.
RDAC REGISTER
The RDAC register directly controls the position of the digital
rheostat wiper. For example, when the RDAC register is loaded
with all 0s, the wiper is connected to Terminal A of the variable
resistor. The RDAC register is a standard logic register, and there
is no restriction on the number of changes allowed. The basic
mode of setting the variable resistor wiper position (programming
the RDAC register) is accomplished by loading the serial data
input register with Command 1 (see Table 6) and with the desired
wiper position data.
50-TP MEMORY BLOCK
The AD5174 contains an array of 50-TP programmable memory
registers, which allow the wiper position to be programmed up
to 50 times. Table 10 shows the memory map. When the desired
wiper position is determined, the user can load the serial data
input register with Command 3 (see Table 6), which stores the
wiper position data in a 50-TP memory register. The first address
to be programmed is Location 0x01 (see Table 10); the AD5174
increments the 50-TP memory address for each subsequent
program until the memory is full. Programming data to 50-TP
consumes approximately 4 mA for 55 ms, and takes approximately 350 ms to complete, during which time the shift register
locks to prevent any changes from occurring. Bit C2 of the
control register can be polled to verify that the fuse program
command was completed properly. No change in supply voltage
is required to program the 50-TP memory; however, a 1 μF
capacitor on the EXT_CAP pin is required (see Figure 28).
Prior to 50-TP activation, the AD5174 presets to midscale
on power-up.
WRITE PROTECTION
At power-up, the serial data input register write commands for
both the RDAC register and the 50-TP memory registers are
disabled. The RDAC write protect bit, C1, of the control register
(see Table 8 and Table 9) is set to 0 by default. This disables any
change of the RDAC register content regardless of the software
commands, except that the RDAC register can be refreshed
from the 50-TP memory using the software reset, Command 4
(see Table 6). To enable programming of the RDAC register,
the write protect bit (Bit C1), of the control register must first
be programmed by loading the serial data input register with
Command 7. To enable programming of the 50-TP memory,
the program enable bit (Bit C0) of the control register, which
is set to 0 by default, must first be set to 1.
Rev. 0 | Page 12 of 20
AD5174
Data from the selected memory location is clocked out of the
SDO pin during the next SPI operation. A binary encoded version
address of the most recently programmed wiper memory location
can be read back using Command 6 (see Table 6). This can be used
to monitor the spare memory status of the 50-TP memory block.
RDAC AND 50-TP READ OPERATION
A serial data output SDO pin is available for readback of
the internal RDAC register or 50-TP memory contents. The
contents of the RDAC register can be read back through
SDO by using Command 2 (see Table 6). Data from the
RDAC register is clocked out of the SDO pin during the last
10 clocks of the next SPI operation.
Table 7 provides a sample listing for the sequence of serial data
input (DIN) words with the serial data output appearing at the
SDO pin in hexadecimal format for a write and read to both the
RDAC register and the 50-TP memory (Memory Location 20).
It is possible to read back the contents of any of the 50-TP
memory registers through SDO by using Command 5. The
lower six LSB bits, D5 to D0 of the data byte, select which
memory location is to be read back, as shown in Table 10.
Table 6. Command Operation Truth Table
D7
X
D7
Data[DB9:DB0] 1
D6 D5 D4 D3
X
X
X
X
D6 D5 D4 D3
D2
X
D2
D1
X
D1
D0
X
D0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0
X
X
X
X
X
X
X
X
X
X
0
1
X
X
X
X
D5
D4
D3
D2
D1
D0
1
1
0
X
X
X
X
X
X
X
X
X
X
0
1
1
1
X
X
X
X
X
X
X
X
D1
D0
1
1
0
0
0
0
0
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
D0
Command
Number
0
1
Command[DB13:DB10]
C3
C2
C1
C0
0
0
0
0
0
0
0
1
D9
X
D9
D8
X
D8
2
0
0
1
0
X
3
0
0
1
1
4
0
1
0
52
0
1
6
0
73
8
9
1
X is don’t care.
See Table 10 for 50-TP memory map.
3
See Table 9 for bit details.
2
Rev. 0 | Page 13 of 20
Operation
NOP: do nothing.
Write contents of serial register
data to RDAC.
Read contents of RDAC wiper
register.
Store wiper setting: store RDAC
setting to 50-TP.
Software reset: refresh RDAC with
last 50-TP memory stored value.
Read contents of 50-TP from SDO
output in the next frame.
Read address of last 50-TP
programmed memory location.
Write contents of serial register
data to control register.
Read contents of control register.
Software shutdown.
D0 = 0; normal mode.
D0 = 1; device placed in shutdown
mode.
AD5174
SHUTDOWN MODE
RESET
The AD5174 can be shut down by executing the software
shutdown command, Command 9 (see Table 6), and setting
the LSB to 1. This feature places the RDAC in a zero-powerconsumption state where Terminal A is open circuited and
the wiper terminal, W, remains connected. It is possible to
execute any command from Table 6 while the AD5174 is in
shutdown mode. The parts can be taken out of shutdown
mode by executing Command 9 and setting the LSB to 0
or by a software reset, Command 4 (see Table 6).
The AD5174 can be reset through software by executing Command 4 (see Table 6). The reset command loads the RDAC
register with the contents of the most recently programmed 50-TP
memory location. The RDAC register loads with midscale if no
50-TP memory location has been previously programmed.
Table 7. Write and Read to RDAC and 50-TP Memory
DIN
0x1C03
0x0500
0x0800
0x0C00
SDO 1
0xXXXX
0x1C03
0x0500
0x100
0x1800
0x0000
0x0C00
0xXX19
0x1419
0x2000
0x0000
0x0100
0x0000
0xXXXX
1
Action
Enable update of the wiper position and the 50-TP memory contents through the digital interface.
Write 0x100 to the RDAC register; wiper moves to ¼ full-scale position.
Prepares data read from RDAC register.
Stores RDAC register content into the 50-TP memory. A 16-bit word appears out of SDO, where the last 10 bits contain
the contents of the RDAC register (0x100).
Prepares data read of the last programmed 50-TP memory monitor location.
NOP Instruction 0 sends a 16-bit word out of SDO, where the six LSBs (that is, last six bits) contain the binary address of
the last programmed 50-TP memory location, for example, 0x19 (see Table 10).
Prepares data read from Memory Location 0x19.
Prepares data read from the control register. Sends a 16-bit word out of SDO, where the last 10 bits contain the
contents of Memory Location 0x19.
NOP Instruction 0 sends a 16-bit word out of SDO, where the last four bits contain the contents of the control register.
If Bit C2 = 1, the fuse program command was successful.
X is don’t care.
Table 8. Control Register Bit Map
D9
0
D8
0
D7
0
D6
0
D5
0
D4
0
D3
C2
D2
0
D1
C1
D0
C0
Table 9. Control Register Bit Description
Bit Name
C0
C1
C2
1
Description
50-TP program enable
0 = 50-TP program disabled (default)
1 = enable device for 50-TP program
RDAC register write protect
0 = wiper position frozen to value in 50-TP memory (default) 1
1 = allow update of wiper position through digital interface
50-TP memory program success bit
0 = fuse program command was unsuccessful (default)
1 = fuse program command was successful
Wiper position frozen to the last value programmed in the 50-TP memory. The wiper is frozen to midscale if the 50-TP memory has not been previously programmed.
Rev. 0 | Page 14 of 20
AD5174
Table 10. Memory Map
Command Number
5
1
D9
X
X
X
X
X
…
X
…
X
…
X
…
X
…
X
…
X
X
D8
X
X
X
X
X
…
X
…
X
…
X
…
X
…
X
…
X
X
D7
X
X
X
X
X
…
X
…
X
…
X
…
X
…
X
…
X
X
Data Byte[DB9:DB0] 1
D6
D5
D4
D3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
…
…
…
…
0
0
0
1
…
…
…
…
0
0
1
0
…
…
…
…
0
0
1
1
…
…
…
…
0
1
0
1
…
…
…
…
0
1
1
0
…
…
…
…
0
1
1
1
0
1
1
1
D2
0
0
0
0
1
…
0
…
1
…
1
…
0
…
0
…
0
0
D1
0
0
1
1
0
…
1
…
0
…
1
…
0
…
1
…
0
1
D0
0
1
0
1
0
…
0
…
0
…
0
…
0
…
0
…
1
0
Register Contents
Reserved
1st programmed wiper location (0x01)
2nd programmed wiper location (0x02)
3rd programmed wiper location (0x03)
4th programmed wiper location (0x04)
…
10th programmed wiper location (0xA)
…
20th programmed wiper location (0x14)
…
30th programmed wiper location (0x1E)
…
40th programmed wiper location (0x28)
…
50th programmed wiper location (0x32)
…
MSB resistance tolerance (0x39)
LSB resistance tolerance (0x3A)
X is don’t care.
DAISY-CHAIN OPERATION
RDAC ARCHITECTURE
The serial data output pin (SDO) serves two purposes: it can be
used to read the contents of the wiper setting and 50-TP values
using Command 2 and Command 5, respectively (see Table 6),
or the SDO pin can be used in daisy-chain mode. The remaining
instructions are valid for daisy chaining multiple devices in
simultaneous operations. Data is clocked out of SDO on the
rising edge of SCLK. Daisy chaining minimizes the number
of port pins required from the controlling IC. The SDO pin
contains an open-drain N-channel FET that requires a pull-up
resistor if this pin is used. As shown in Figure 26, users need
to tie the SDO pin of one package to the DIN pin of the next
package. Users may need to increase the clock period, because
the pull-up resistor and the capacitive loading at the SDO-toDIN interface may require additional time delay between
subsequent devices. When two AD5174 devices are daisychained, 32 bits of data are required. The first 16 bits go
to U2, and the second 16 bits go to U1. Keep the SYNC pin
low until all 32 bits are clocked into their respective serial
registers. The SYNC pin is then pulled high to complete the
operation.
To achieve optimum performance, Analog Devices, Inc., has
patented the RDAC segmentation architecture for all the digital
potentiometers. In particular, the AD5174 employs a three-stage
segmentation approach as shown in Figure 27. The AD5174
wiper switch is designed with the transmission gate CMOS
topology.
VDD
AD5174
U1
MOSI
DIN
SDO
RP
2.2kΩ
AD5174
U2
DIN
SDO
µC
SS
SYNC
SCLK
SYNC SCLK
08718-006
SCLK
Figure 26. Daisy-Chain Configuration Using SDO
Rev. 0 | Page 15 of 20
A
RL
RL
RM
SW
RW
W
RW
08718-007
10-BIT
ADDRESS
DECODER
RM
Figure 27. Simplified RDAC Circuit
AD5174
PROGRAMMING THE VARIABLE RESISTOR
Calculate the Actual End-to-End Resistance
Rheostat Operation
The resistance tolerance is stored in the internal memory
during factory testing. The actual end-to-end resistance can,
therefore, be calculated (which is valuable for calibration,
tolerance matching, and precision applications).
The nominal resistance between Terminal W and Terminal A,
RWA, is 10 kΩ and has 1024-tap points accessed by the wiper terminal. The 10-bit data in the RDAC latch is decoded to select
one of the 1024 possible wiper settings. As a result, the general
equation for determining the digitally programmed output
resistance between the W terminal and the A terminal is
RWA (D) =
D
× RWA
1024
The resistance tolerance (in percentage) is stored in fixed-point
format, using a 16-bit sign magnitude binary. The sign bit(0 =
negative and 1 = positive) and the integer part is located in
Address 0x39 as shown in Table 10. Address 0x3A contains the
fractional part as shown in Table 11.
(1)
where:
D is the decimal equivalent of the binary code loaded in the
10-bit RDAC register.
RWA is the end-to-end resistance.
That is, if the data readback from Address 0x39 is 0000001010 and
data from Address 0x3A is 0010110000, then the end-to-end
resistance can be calculated as follows.
In the zero-scale condition, a finite total wiper resistance of
120 Ω is present. Regardless of which setting the part is operating in, take care to limit the current between Terminal A and
Terminal W to the maximum continuous current of ±6 mA or
a pulse current specified in Table 3. Otherwise, degradation or
possible destruction of the internal switch contact may occur.
DB[9:8]: XX = don’t care
For Memory Location 0x39,
DB[7]: 0 = negative
DB[6:0]: 0001010 = 10
For Memory Location 0x3A,
DB[9:8]: XX = don’t care
DB[7:0]: 10110000 = 176 × 2−8 = 0.6875
Therefore, tolerance = −10.6875% and RWA (1023)= 8.931 kΩ.
Table 11. End-to-End Resistance Tolerance Bytes
Memory Map Address
0x39
0x3A
1
DB9
X
X
DB8
X
X
DB7
Sign
2−1
DB6
26
2−2
X is don’t care.
Rev. 0 | Page 16 of 20
Data Byte 1
DB5
DB4
25
24
2−3
2−4
DB3
23
2−5
DB2
22
2−6
DB1
21
2−7
DB0
20
2−8
AD5174
EXT_CAP CAPACITOR
A 1 μF capacitor to VSS must be connected to the EXT_CAP
pin, as shown in Figure 28, on power-up and throughout the
operation of the AD5174.
AD5174
EXT_CAP
C1
1µF
50-TP
MEMORY
BLOCK
POWER-UP SEQUENCE
08718-008
VSS
VSS
The ground pin of the AD5174 is primarily used as a digital
ground reference. To minimize the digital ground bounce, join the
AD5174 ground terminal remotely to the common ground. The
digital input control signals to the AD5174 must be referenced
to the device ground pin (GND) and must satisfy the logic level
defined in the Specifications section. An internal level shift
circuit ensures that the common-mode voltage range of the
three terminals extends from VSS to VDD, regardless of the
digital input level.
Figure 28. EXT_CAP Hardware Setup
TERMINAL VOLTAGE OPERATING RANGE
The positive VDD and negative VSS power supplies of the AD5174
define the boundary conditions for proper 2-terminal digital
resistor operation. Supply signals present on Terminal A and
Terminal W that exceed VDD or VSS are clamped by the internal
forward-biased diodes (see Figure 29).
VDD
Because there are diodes to limit the voltage compliance at
Terminal A and Terminal W (see Figure 29), it is important to
power VDD/VSS first before applying any voltage to Terminal A
and Terminal W; otherwise, the diode is forward-biased such
that VDD/VSS are powered unintentionally. The ideal powerup sequence is VSS, GND, VDD, digital inputs, VA, and VW.
The order of powering VA, VW, and the digital inputs is not
important as long as they are powered after VDD/VSS.
As soon as VDD is powered, the power-on preset activates,
which first sets the RDAC to midscale and then restores the
last programmed 50-TP value to the RDAC register.
A
VSS
08718-009
W
Figure 29. Maximum Terminal Voltages Set by VDD and VSS
Rev. 0 | Page 17 of 20
AD5174
OUTLINE DIMENSIONS
2.48
2.38
2.23
3.10
3.00 SQ
2.90
0.50 BSC
6
PIN 1 INDEX
AREA
10
1.74
1.64
1.49
EXPOSED
PAD
0.50
0.40
0.30
5
TOP VIEW
0.80
0.75
0.70
PIN 1
INDICATOR
(R 0.15)
FOR PROPER CONNECTION OF
THE EXPOSED PAD, REFER TO
THE PIN CONFIGURATION AND
FUNCTION DESCRIPTIONS
SECTION OF THIS DATA SHEET.
0.05 MAX
0.02 NOM
0.30
0.25
0.20
0.20 REF
121009-A
SEATING
PLANE
1
BOTTOM VIEW
Figure 30. 10-Lead Frame Chip Scale Package [LFCSP_WD]
3 mm × 3mm Body, Very Thin, Dual Lead
(CP-10-9)
Dimensions shown in millimeters
3.10
3.00
2.90
10
3.10
3.00
2.90
1
5.15
4.90
4.65
6
5
PIN 1
IDENTIFIER
0.50 BSC
0.95
0.85
0.75
15° MAX
1.10 MAX
0.30
0.15
0.23
0.13
6°
0°
0.70
0.55
0.40
COMPLIANT TO JEDEC STANDARDS MO-187-BA
091709-A
0.15
0.05
COPLANARITY
0.10
Figure 31. 10-Lead Mini Small Outline Package [MSOP]
(RM-10)
Dimensions shown in millimeters
ORDERING GUIDE
Model1
AD5174BRMZ-10
AD5174BRMZ-10-RL7
AD5174BCPZ-10-R2
AD5174BCPZ-10-RL7
1
RAB (kΩ)
10
10
10
10
Resolution
1,024
1,024
1,024
1,024
Temperature Range
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
−40°C to +125°C
Package Description
10-Lead MSOP
10-Lead MSOP
10-Lead LFCSP_WD
10-Lead LFCSP_WD
Z = RoHS Compliant Part.
Rev. 0 | Page 18 of 20
Package Option
RM-10
RM-10
CP-10-9
CP-10-9
Branding
DDT
DDT
DEF
DEF
AD5174
NOTES
Rev. 0 | Page 19 of 20
AD5174
NOTES
©2010 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D08718-0-3/10(0)
Rev. 0 | Page 20 of 20
Similar pages