MPD MPM-30T-5312CM Chassis mount, 30w single, dual & triple out ac/dc power supply Datasheet

MPM-30CM Series
Ch
Chassis
i M
Mount,
t 30W
Single, Dual & Triple Out
AC/DC Power Supplies
Key Features:
• 30W Output Power
• Universal 85-265 VAC Input
• EN60950 Approved
• Single, Dual & Triple Outputs
• Meets EN55022 B
• Meets IEC Safety Class II
• Chassis Mount Case
DIN Rail Mounting
Kit Available!
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Inrush Current
EMI
Safety Ground Leakage Current
Conditions
Min.
Typ.
Max.
85
265
47
440
See Model Selection Guide
115 VAC
20.0
230 VAC
40.0
Meets CISPR Pub. 22/FCC Class B
115 VAC
0.1
230 VAC
0.3
Units
VAC
Hz
Conditions
Min.
Typ.
Max.
See Model Selection Guide
See Model Selection Guide
±1.0
±2.0
VIN = Min to Max
±0.2
±1.0
IO = Min to Max
±0.5
±1.0
IO = Min to Max
±2.5
±5.0
IO = Min to Max
±2.5
±5.0
IO = Min to Max
±4.0
3.3 & 5.0 VDC Output
1.5
1.8
All Other Outputs
1.0
1.3
115 VAC, 60 Hz
20
±0.02
Zener Diode Clamp
120
Continuous (Autorecovery)
Typ. 120% to 180% of Output Power
Units
A Pk
mA
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy, Note 1
Line Regulation
Load Regulation, Single Output
Load Regulation, Dual Output
Load Regulation, Triple Output - Primary
Load Regulation, Triple Output - Aux.
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, Note 4
Overload Protection, Note 5
%
%
%
%
%
%
%VP-P of VO
mSec
%/°C
% of VO
General
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
EMI/RFI
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
EMC Compliance
Conditions
Input to Output
Input to Output, Flash Tested For 60S
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Switching Frequency
Min.
3,000
4,700
100
Typ.
Max.
Units
VAC
VAC
MΩ
EN 55022 Level B
IEC/EN 61000-4-2 Level B
IEC/EN61000-4-3
IEC/EN 61000-4-4 Level 3 2 kV
IEC/EN 61000-4-5 Level 3 1kV/2 kV
100
kHz
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
Max.
-25
+25
+71
-40
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
Physical
Case Size, Chassis Mount
Case Size, DIN Rail Option
Case Material
Weight
4.41 x 2.51 x 1.01 Inches (112.0 x 63.8 x 25.6 mm)
4.41 x 2.51 x 1.44 Inches (112.0 x 63.8 x 36.6 mm)
Non-Conductive Plastic& Fiberglass (UL94-V0)
6.72 Oz (191g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
250
IEN 60950, IEC 60950
IEN 60950, IEC 60950
IEC 61140 Class II
Max.
Units
kHours
Model Selection Guide
Output 2 (Vout 2)
Current (A)
Voltage
(VDC)
Max.
Min.
Input
Current (A)
Output 1 (Vout 1)
Current (A)
Voltage
115 VAC 230 VAC (VDC)
Max.
Min.
Model
Number
MPM-30S-05CM
MPM-30S-12CM
MPM-30S-15CM
MPM-30S-24CM
MPM-30S-48CM
MPM-30D-12CM
MPM-30D-15CM
MPM-30T-0512CM
MPM-30T-0512CMA
MPM-30T-0515CM
MPM-30T-5312CM
MPM-30T-3512CM
0.557
0.543
0.543
0.543
0.543
0.565
0.543
0.572
0.572
0.572
0.588
0.483
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
5.0
12.0
15.0
24.0
48.0
+12.0
+15.0
5.0
5.0
5.0
5.0
3.3
6.000
2.500
2.000
1.250
0.625
+1.300
+1.000
3.000
3.000
3.000
4.500
4.000
0.600
0.250
0.200
0.125
0.063
+0.130
+0.100
+0.600
+0.600
+0.300
+0.900
+0.800
-12.0
-15.0
+12.0
+12.0
+15.0
+3.3
+5.0
-1.300
-1.000
+0.600
+1.000
+0.500
+1.000
+1.500
-0.130
-0.100
+0.120
+0.200
+0.050
+0.220
+0.300
Output 3 (Vout 3)
Current (A)
Voltage
(VDC)
Max.
Min.
-12.0
-12.0
-15.0
+12.0
+12.0
-0.600
-0.250
-0.500
+0.250
+0.250
-0.120
-0.050
-0.050
+0.050
+0.050
Capacitive
Efficiency
Load
(%, Typ)
(µF, Max)
8,000
3,900
3,900
1,500
1,000
±1,500
±1,500
See Note 6
See Note 6
See Note 6
See Note 6
See Note 6
78
80
80
80
80
80
80
76
76
76
71
71
Derating Curve
Other output combinations are available
Contact the factory for details at:
[email protected]
Notes:
1. For triple output models, the output voltage accuracy of the auxilliary outputs
is typically ±4%.
2. Load regulation is measured for an output change of 0% to 100% at nominal
input line. For multiple output models, the loads are balanced.
3. Operation at no-load will not damage these units. However, they may not
meet all specifications.
4. Output short circuit protection is provided by a “hiccup mode” circuit. The
unit recovers automatically when the fault condition is removed.
5. Output overload protection is provided by a fold back current limiting
circuit.
6. For triple output models, the maximum capacitive load for 5 VDC and 3.3VDC
outputs is 2,200 µF. For all other outputs it is ±1,500 µF.
7. The MPM-30CM series includes a built-in 3.5A/250 VAC fuse. It is recommended that an external 1.5A slow blow fuse also be used on the input for
protection.
Mechanical Dimensions, Chassis Mount
Pin Connections
Pin
Single
Dual
Triple
1
AC-Neutral
2
AC-Line
3
+Vo
+Vo
+Vo 2
4
NC
NC
+Vo 1
5
-Vo
Common
Common 2/3
6
NC
NC
-Vo 1
7
NC
-Vo
+Vo 3
NC = No Connection
A DIN Rail mounting kit is available
Contact the factory for details at:
[email protected]
MicroPower Direct
Notes:
• All dimensio
dimensions are typical in inches (mm)
• Tolerance x.
x.xx = ±0.01 (±0.25)
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages