ADPOW APT30D40H Ultrafast soft recovery rectifier diode Datasheet

1
2
1 - Cathode
2 - Anode
Case Isolated
APT30D40H
400V
30A
1
2
ULTRAFAST SOFT RECOVERY RECTIFIER DIODE
PRODUCT FEATURES
PRODUCT BENEFITS
• Anti-Parallel Diode
• Ultrafast Recovery Times
• Low Losses
• Soft Recovery Characteristics
• Low Noise Switching
• Popular TO-258 Package
• Cooler Operation
• Low Forward Voltage
• Higher Reliability Systems
• High Blocking Voltage
• Increased System Power
•
•
•
•
• Low Leakage Current
All Ratings: TC = 25°C unless otherwise specified.
MAXIMUM RATINGS
IN
VR
Characteristic / Test Conditions
Maximum D.C. Reverse Voltage
IM
Symbol
Density
A
•
-Switchmode Power Supply
-Inverters
Free Wheeling Diode
-Motor Controllers
-Converters
Snubber Diode
Uninterruptible Power Supply (UPS)
Induction Heating
High Speed Rectifiers
RY
PRODUCT APPLICATIONS
APT30D40H
UNIT
400
Volts
Maximum Peak Repetitive Reverse Voltage
VRWM
Maximum Working Peak Reverse Voltage
IF(AV)
Maximum Average Forward Current (TC = 105°C, Duty Cycle = 0.5)
30
RMS Forward Current
70
IFSM
TJ,TSTG
TL
Amps
320
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms)
PR
IF(RMS)
EL
VRRM
-55 to 150
Operating and StorageTemperature Range
°C
300
Lead Temperature: 0.063" from Case for 10 Sec.
STATIC ELECTRICAL CHARACTERISTICS
Characteristic / Test Conditions
MIN
TYP
IRM
2.0
IF = 60A
Maximum Forward Voltage
Maximum Reverse Leakage Current
UNIT
1.75
IF = 30A
VF
MAX
Volts
IF = 30A, TJ = 150°C
1.53
VR = VR Rated
250
VR = VR Rated, TJ = 125°C
500
µA
CT
Junction Capacitance, VR = 200V
52
pF
LS
Series Inductance (Lead to Lead 5mm from Base)
10
nH
USA
APT Website - http://www.advancedpower.com
405 S.W. Columbia Street
Bend, Oregon 97702-1035
Phone: (541) 382-8028
FAX: (541) 388-0364
F-33700 Merignac - France
Phone: (33) 5 57 92 15 15
FAX: (33) 5 56 47 97 61
EUROPE
Avenue J.F. Kennedy Bât B4 Parc Cadéra Nord
053-4017 Rev -
Symbol
APT30D40H
DYNAMIC CHARACTERISTICS
Symbol
Characteristic
MIN
TYP
MAX
65
trr1
Reverse Recovery Time, IF = 1.0A, diF /dt = -15A/µs, VR = 30V, TJ = 25°C
45
trr2
Reverse Recovery Time
TJ = 25°C
45
trr3
IF = 30A, diF /dt = -240A/µs, VR = 240V
TJ = 100°C
70
tfr1
Forward Recovery Time
TJ = 25°C
150
tfr2
IF = 30A, diF /dt = 240A/µs, VR = 240V
TJ = 100°C
150
IRRM1
Reverse Recovery Current
TJ = 25°C
6
10
IRRM2
IF = 30A, diF /dt = -240A/µs, VR = 240V
TJ = 100°C
10
18
Qrr1
Recovery Charge
TJ = 25°C
135
Qrr2
IF = 30A, diF /dt = -240A/µs, VR = 240V
TJ = 100°C
350
Vfr1
Forward Recovery Voltage
TJ = 25°C
3.2
Vfr2
IF = 30A, diF /dt = 240A/µs, VR = 240V
RY
A
nC
Volts
TJ = 100°C
3.2
TJ = 25°C
500
TJ = 100°C
500
A/µs
IM
IF = 30A, diF /dt = -240A/µs, VR = 240V (See Figure 10)
ns
Amps
IN
Rate of Fall of Recovery Current
diM/dt
UNIT
Symbol
EL
THERMAL AND MECHANICAL CHARACTERISTICS
Characteristic / Test Conditions
Junction-to-Case Thermal Resistance
RθJA
Junction-to-Ambient Thermal Resistance
WT
TYP
MAX
0.90
40
PR
RθJC
MIN
UNIT
°C/W
0.22
oz
6.1
gm
Package Weight
lb•in
Torque
Maximum Mounting Torque (Screw Type = 6-32 or 3mm Machine)
N•m
TO-258 Package Outline
17.65 (.695)
17.39 (.685)
1.14 (.045)
0.88 (.035)
8.89 (.350)
8.63 (.340)
4.19 (.165)
3.94 (.155)
21.21 (.835)
20.70 (.815)
13.84 (.545)
13.58 (.535)
17.96 (.707)
17.70 (.697)
Drain
19.05 (0.750)
12.70 (0.500)
Source
053-4017 Rev -
Gate
3.56 (.140) BSC
6.86 (.270)
6.09 (.240)
1.65 (.065) Dia. Typ.
1.39 (.055) 3 Leads
5.08 (.200) BSC
Dimensions in Millimeters and (Inches)