Current Transducer HAT 200 .. 1500-S For the electronic measurement of currents: DC, AC, pulsed,..., with galvanic separation between the primary circuit and the secondary circuit. IPN = 200 .. 1500 A Vout = ± 4 V Electrical data Type Primary nominal Primary current, RoHS since rms current measuring range 1) date code IPN (A) IPM (A) HAT 200-S 200 ± 600 47143 HAT 400-S 400 ± 1200 46115 HAT 500-S 500 ± 1500 46129 HAT 600-S 600 ± 1800 46115 HAT 800-S 800 ± 2400 46115 HAT 1000-S 1000 ± 2500 46097 HAT 1200-S 1200 ± 2500 77271 HAT 1500-S 1500 ± 2500 46158 I UC Supply voltage (± 5 %) 1) ± 15 V IC Current consumption ± 15 mA RIS Insulation resistance @ 500 V DC > 1000 MΩ Vout Output voltage (Analog) @ ± IPN, RL = 10 kΩ, TA = 25 °C ± 4 V Rout Output internal resistance 100 Ω RL Load resistance > 10 kΩ p Accuracy - Dynamic performance data X Accuracy @ IPN, TA = 25 °C (excluding offset) ≤ ± 1 % of IPN εL Linearity error 2) (0 .. ± IPN) ≤ ± 1 % of IPN VOE Electrical offset voltage @ TA = 25 °C < ± 20 mV VOH Hysteresis offset voltage @ IP = 0, after an excursion of 1 x IPN < ± 10 mV TCVOE Temperature coefficient of VOE - 40 °C .. + 80 °C < ± 1 mV/K + 80 °C .. + 105 °C < ± 1.5 mV/K TCVout Temperature coefficient of Vout (% of reading) < ± 0.1 %/K tr Step response time to 90 % of IPN < 5 µs di/dt di/dt accurately followed > 50 A/µs BW Frequency bandwidth 3) (- 3 dB) DC .. 25 kHz General data TA TS m Ambient operating temperature Ambient storage temperature Mass Standards - 40 .. + 105 °C - 40 .. + 105 °C 300 g EN 50178: 1997 UL 508: 2010 4) Featuresd CI dCp ●● Hall effect measuring principle ●● Insulating plastic case recognized according to UL 94-V0. Advantages ●● R ●● ●● ●● UC Easy installation Low power consumption U size and space saving Small Only one design for wide current ratings range ●● High immunity to external interference. M C Applications ●● DC motor drives ●● Switched Mode Power Supplies (SMPS) ●● AC variable speed drives ●● Uninterruptible Power Supplies (UPS) ●● Battery supplied applications ●● Power supplies for welding applications. Application domain ●● Industrial. Notes: 1)Operating at ± 12 V ≤ UC < ± 15 V will reduce the measuring range 2) Linearity data exclude the electrical offset 3) Please refer to derating curves in the technical file to avoid excessive core heating at high frequency 4) UL conform is only applicable @ TA = - 40 °C .. + 85 °C. N° 64.02.44.000.0, N° 64.02.48.000.0, N° 64.02.50.000.0, N° 64.02.52.000.0 N° 64.02.56.000.0, N° 64.02.60.000.0, N° 64.02.62.000.0, N° 64.02.65.000.0 9January2014/version 21 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice Page 1/3 www.lem.com Current Transducer HAT 200 .. 1500-S Insulation coordination Ud ÛW dCp dCI CTI Rms voltage for AC insulation test, 50 Hz, 1 min Impulse withstand voltage 1.2/50 µs Creepage distance Clearance Comparative tracking index (group IIIa) 4.9 > 9.9 Min 11 11 275 kV kV mm mm Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: ●● Over voltage category III ●● Pollution degree PD2 ●● Non-uniform field EN 50178 IEC 61010-1 Rated insulation voltage Nominal voltage Basic insulation 1100 V 1100 V Reinforced insulation 550 V 550 V dCp, dCI, ÛW Safety This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 9January2014/version 21 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com Dimensions HAT 200 .. 1500-S (in mm) 第一视角 第三视角 第一视角 第三视角 dCp dCI dCI dCI Connection UC Ip Ip UC RM UC R M Ip dCI dCp UC UC RM UC Mechanical characteristics Remarks ●● General tolerance ●● Transducer fastening ●● Vout is positive when IP flows in the direction of the arrow. ●● Temperature of the primary conductor should not exceed 105 °C. UC ± 1 mm By base-plate or on busbar Ip with M4 screws All holes Ø 4.5 mm Recommended fastening torque 1.2 N·m (± 10 %) ●● Connection of secondary Molex 5045-04A ●● Installation of the transducer must be done unless RM specified on the datasheet, according to LEM otherwise Transducer Generic Mounting Rules. Please refer to U C LEM document N°ANE120504 available on our Web site: Products/Product Documentation. Page 3/3 9January2014/version 21 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com