Sanken GKI04048 N ch trench power mosfet Datasheet

40 V, 26 A, 4.2 mΩ Low RDS(ON)
N ch Trench Power MOSFET
GKI04048
Features
Package
 V(BR)DSS --------------------------------- 40 V (ID = 100 µA)
 ID ---------------------------------------------------------- 26 A
 RDS(ON) ---------- 5.4 mΩ max. (VGS = 10 V, ID = 35.4 A)
 Qg ------16.0 nC (VGS = 4.5 V, VDS = 20 V, ID = 42.8 A)
 Low Total Gate Charge
 High Speed Switching
 Low On-Resistance
 Capable of 4.5 V Gate Drive
 100 % UIL Tested
 RoHS Compliant
DFN 5 × 6 (L)
8pin
8pin
D
D
D
D
S
S
S G
D
G
D
D
D
S
S
S
1pin
1pin
Not to scale
Applications
Equivalent circuit
 DC-DC converters
 Synchronous Rectification
 Power Supplies
D(5)(6)(7)(8)
G(4)
S(1)(2)(3)
Absolute Maximum Ratings
 Unless otherwise specified, TA = 25 °C
Parameter
Symbol
Drain to Source Voltage
VDS
Gate to Source Voltage
VGS
Continuous Drain Current
Pulsed Drain Current
ID
IDM
Continuous Source Current
(Body Diode)
Pulsed Source Current
(Body Diode)
ISM
Single Pulse Avalanche Energy
EAS
Avalanche Current
IAS
Power Dissipation
Operating Junction Temperature
Test conditions
TC = 25 °C,
with infinite heatsink
TA = 25 °C,
mounted on PCB*
PW ≤ 100µs
Duty cycle ≤ 1 %
IS
PD
PW ≤ 100µs
Duty cycle ≤ 1 %
VDD = 20V, L = 1 mH,
IAS = 9.4 A, unclamped,
RG = 4.7 Ω,
Refer to Figure 1
TC = 25 °C,
with infinite heatsink
TA = 25 °C,
mounted on PCB*
TJ
Storage Temperature Range
TSTG
* 1 inch square 2 oz copper pad on 1.5 × 1.5 inch PCB.
GKI04048-DS Rev.1.2
Jan. 24, 2014
SANKEN ELECTRIC CO.,LTD.
http://www.sanken-ele.co.jp
Rating
Unit
40
V
± 20
V
26
A
14
A
51
A
26
A
51
A
89
mJ
16.7
A
59
W
3.1
W
150
°C
− 55 to 150
°C
1
GKI04048
Thermal Characteristics
 Unless otherwise specified, TA = 25 °C
Parameter
Symbol
Test Conditions
Thermal Resistance
RθJC
(Junction to Case)
Thermal Resistance
Mounted on PCB*
RθJA
(Junction to Ambient)
* 1 inch square 2 oz copper pad on 1.5 × 1.5 inch PCB.
Min.
Typ.
Max.
Unit
−
−
2.1
°C/W
−
−
40.3
°C/W
Min.
Typ.
Max.
Unit
Electrical Characteristics
 Unless otherwise specified, TA = 25 °C
Parameter
Drain to Source Breakdown
Voltage
Drain to Source Leakage Current
Symbol
V(BR)DSS
ID = 100 μA, VGS = 0 V
40
−
−
V
IDSS
VDS = 40 V, VGS = 0 V
−
−
100
µA
Gate to Source Leakage Current
IGSS
VGS = ± 20 V
−
−
± 100
nA
VDS = VGS, ID = 650 µA
1.0
2.0
2.5
V
ID = 35.4 A, VGS = 10 V
−
4.2
5.4
mΩ
ID = 17.7 A, VGS = 4.5 V
−
5.4
7.5
mΩ
f = 1 MHz
−
1.5
−
Ω
−
2410
−
−
395
−
−
190
−
−
35.0
−
−
16.0
−
−
5.6
−
−
6.0
−
−
4.1
−
−
5.6
−
−
19.7
−
−
11.9
−
IS = 35.4 A, VGS = 0 V
−
0.9
1.5
V
IF = 42.8 A
di/dt = 100 A/µs
Refer to Figure 3
−
32.9
−
ns
−
30.3
−
nC
Gate Threshold Voltage
VGS(th)
Static Drain to Source
On-Resistance
RDS(ON)
Gate Resistance
RG
Input Capacitance
Ciss
Output Capacitance
Coss
Reverse Transfer Capacitance
Crss
Total Gate Charge (VGS = 10 V)
Qg1
Total Gate Charge (VGS = 4.5 V)
Qg2
Gate to Source Charge
Qgs
Gate to Drain Charge
Qgd
Turn-On Delay Time
td(on)
Rise Time
Turn-Off Delay Time
Fall Time
Source to Drain Diode Forward
Voltage
Source to Drain Diode Reverse
Recovery Time
Source to Drain Diode Reverse
Recovery Charge
GKI04048-DS Rev.1.2
Jan. 24, 2014
tr
td(off)
Test Conditions
VDS = 25 V
VGS = 0 V
f = 1 MHz
VDS = 20 V
ID = 42.8 A
VDD = 20 V
ID = 42.8 A
VGS = 10 V, RG = 4.7 Ω
Refer to Figure 2
tf
VSD
trr
Qrr
SANKEN ELECTRIC CO.,LTD.
pF
nC
ns
2
GKI04048
Test Circuits and Waveforms
E AS 
L
V(BR)DSS
1
2
 L  I AS 
2
V(BR)DSS  VDD
V(BR)DSS
ID
VDS
RG
IAS
VDD
VGS
VDS
0V
ID
VDD
(a) Test Circuit
(b) Waveform
Figure 1 Unclamped Inductive Switching
RL
90%
VGS
VDS
10%
RG
VDD
VGS
90%
VDS
0V
10%
td(on) tr
P.W. = 10 μs
Duty cycle ≤ 1 %
td(off) tf
ton
toff
(a) Test Circuit
(b) Waveform
Figure 2 Switching Time
D.U.T.
IF
L
IF
VDD
RG
trr
0V
VGS
IRM × 90 %
di/dt
0V
IRM
(a) Test Circuit
(b) Waveform
Figure 3 Diode Reverse Recovery Time
GKI04048-DS Rev.1.2
Jan. 24, 2014
SANKEN ELECTRIC CO.,LTD.
3
GKI04048
Package Outline
DFN 5 × 6 (L)
Symbol
A
b
C
D
D1
D2
E
E1
E2
e
L
L1
L2
H
I
Min.
1.03
0.34
0.824
4.95
4.11
4.80
5.95
5.65
1.51
Max.
1.17
0.48
0.97
5.15
4.31
5.00
6.15
5.85
--1.27
0.05
0.38
0.74
3.32
0
0.25
0.50
0.86
3.42
0.18
NOTES:
1) Dimension is in millimeters
2) Pb-free. Device composition compliant with the RoHS directive
Marking Diagram
SK
GKI×××××
Part Number
YMDDXXXB
Lot Number
Y is the Last digit of the year (0 to 9)
M is the Month (1 to 9, O, N or D)
DD is the Date (two digit of 01 to 31)
XXX is the suffix No.
B expresses Pb free pins
GKI04048-DS Rev.1.2
Jan. 24, 2014
SANKEN ELECTRIC CO.,LTD.
4
GKI04048
OPERATING PRECAUTIONS
In the case that you use Sanken products or design your products by using Sanken products, the reliability largely
depends on the degree of derating to be made to the rated values. Derating may be interpreted as a case that an operation
range is set by derating the load from each rated value or surge voltage or noise is considered for derating in order to
assure or improve the reliability. In general, derating factors include electric stresses such as electric voltage, electric
current, electric power etc., environmental stresses such as ambient temperature, humidity etc. and thermal stress caused
due to self-heating of semiconductor products. For these stresses, instantaneous values, maximum values and minimum
values must be taken into consideration. In addition, it should be noted that since power devices or IC’s including power
devices have large self-heating value, the degree of derating of junction temperature affects the reliability significantly.
Because reliability can be affected adversely by improper storage environments and handling methods, please
observe the following cautions.
Cautions for Storage
 Ensure that storage conditions comply with the standard temperature (5 to 35°C) and the standard relative humidity
(around 40 to 75%); avoid storage locations that experience extreme changes in temperature or humidity.
 Avoid locations where dust or harmful gases are present and avoid direct sunlight.
 Reinspect for rust on leads and solderability of the products that have been stored for a long time.
Cautions for Testing and Handling
When tests are carried out during inspection testing and other standard test periods, protect the products from power
surges from the testing device, shorts between the product pins, and wrong connections. Ensure all test parameters are
within the ratings specified by Sanken for the products.
Remarks About Using Silicone Grease with a Heatsink
 When silicone grease is used in mounting the products on a heatsink, it shall be applied evenly and thinly. If more
silicone grease than required is applied, it may produce excess stress.
 Volatile-type silicone greases may crack after long periods of time, resulting in reduced heat radiation effect.
Silicone greases with low consistency (hard grease) may cause cracks in the mold resin when screwing the
products to a heatsink.
Our recommended silicone greases for heat radiation purposes, which will not cause any adverse effect on the
product life, are indicated below:
Type
Suppliers
G746
Shin-Etsu Chemical Co., Ltd.
YG6260 Momentive Performance Materials Inc.
SC102
Dow Corning Toray Co., Ltd.
Soldering
When soldering the products, please be sure to minimize the working time, within the following limits:
・Reflow
Preheat ; 180 °C / 90 ± 30 s
Solder heating ; 250 °C / 10 ± 1s (260 °C peak, 2 times)
・Soldering iron ; 380 ± 10 °C / 3.5 ± 0.5s (1 time)
Electrostatic Discharge
 When handling the products, the operator must be grounded. Grounded wrist straps worn should have at least 1MΩ
of resistance from the operator to ground to prevent shock hazard, and it should be placed near the operator.
 Workbenches where the products are handled should be grounded and be provided with conductive table and floor
mats.
 When using measuring equipment such as a curve tracer, the equipment should be grounded.
 When soldering the products, the head of soldering irons or the solder bath must be grounded in order to prevent
leak voltages generated by them from being applied to the products.
 The products should always be stored and transported in Sanken shipping containers or conductive containers, or
be wrapped in aluminum foil.
GKI04048-DS Rev.1.2
Jan. 24, 2014
SANKEN ELECTRIC CO.,LTD.
5
GKI04048
IMPORTANT NOTES
 The contents in this document are subject to changes, for improvement and other purposes, without notice. Make
sure that this is the latest revision of the document before use.
 Application and operation examples described in this document are quoted for the sole purpose of reference for the
use of the products herein and Sanken can assume no responsibility for any infringement of industrial property
rights, intellectual property rights or any other rights of Sanken or any third party which may result from its use.
Unless otherwise agreed in writing by Sanken, Sanken makes no warranties of any kind, whether express or
implied, as to the products, including product merchantability, and fitness for a particular purpose and special
environment, and the information, including its accuracy, usefulness, and reliability, included in this document.
 Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure and
defect of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at
their own risk, preventative measures including safety design of the equipment or systems against any possible
injury, death, fires or damages to the society due to device failure or malfunction.
 Sanken products listed in this document are designed and intended for the use as components in general purpose
electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring
equipment, etc.).
When considering the use of Sanken products in the applications where higher reliability is required (transportation
equipment and its control systems, traffic signal control systems or equipment, fire/crime alarm systems, various
safety devices, etc.), and whenever long life expectancy is required even in general purpose electronic equipment
or apparatus, please contact your nearest Sanken sales representative to discuss, prior to the use of the products
herein.
The use of Sanken products without the written consent of Sanken in the applications where extremely high
reliability is required (aerospace equipment, nuclear power control systems, life support systems, etc.) is strictly
prohibited.
 When using the products specified herein by either (i) combining other products or materials therewith or (ii)
physically, chemically or otherwise processing or treating the products, please duly consider all possible risks that
may result from all such uses in advance and proceed therewith at your own responsibility.
 Anti radioactive ray design is not considered for the products listed herein.
 Sanken assumes no responsibility for any troubles, such as dropping products caused during transportation out of
Sanken’s distribution network.
 The contents in this document must not be transcribed or copied without Sanken’s written consent.
GKI04048-DS Rev.1.2
Jan. 24, 2014
SANKEN ELECTRIC CO.,LTD.
6